http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
電壓勵起에 의한 TSC의 Computer Simulation
金在亨,崔点洙,黃正男 인제대학교 1982 仁濟醫學 Vol.3 No.3
n+-p接合의 空間電荷領域에 형성된 trap에 bias excitation에 의해 hole을 채웠다가 열자극과정에 의해 방출되는 TSC에 대하여 computer simulation 시킨 결과 온도상승율이 증가 할 수록 TSC의 크기는 증가하였고 initial rising法을 적용시킬 수 있는 범위가 ??이었으며 trap depth ΔE가 클 수록 TSP peak는 높은 온도에서 나타났고 TSC 크기는 감소하였다. 그리고 방출율이 클수록 TSP의 peak는 낮은 온도에서 나타냈다. In this study, computer simulations for the hole trap in pn-junction were carried out. The TSC maximum peak and curve shape were varied with varing heating rate, trap level and hole emission rate. The peak temperature(Tm) where the peak appears was increased with increasing trap level, and decreasing hole emission rate. And the maximum intensities of TSC were decreased with increasing trap level and decreasing hole emission rate. The mechanism of pn-junction was found to be the first kinetic order. The optimum temperature range for applying initial rise method was found to be ??.
네마틱 액정 5CB의 광학적 비선형성에 대한 에너지 전달
김재형 인제대학교 1998 仁濟論叢 Vol.14 No.1
Top-hat 빔을 이용한 Z-scan 측정을 통하여 네마틱 액정 5CB에 대해 빔의 세기에 의존하는 광학적 비선형 굴절률 n2와 흡수계수 β를 구하였다. Z-scan 측정에서 감도를 높이기 위해 일반적인 레이저 펄스를 역 망원경의 원리를 이용하여 top-hat beam의 펄스로 만들어 사용하였다. Z-scan 데이터로부터 χ(3)의 실수부와 허수부를 결정하는데는 Zhao등이 제안한 그래프법을 사용하였다. 측정에서 레이저 빔의 세기가 낮을 때 비선형 굴절률은 빔의 강도에 무관한 반면, 비선형 흡수계수는 빔의 세기에 선형적으로 비례하였다. 그리고 ns 시간대에서 나타나는 5CB의 광학적 비선형에 관계되는 반응시간을 측정하기 위하여 2 펄스 Z-scan 실험을 하였다. 비선형 굴절의 반응시간은 10 ns보다 느린 반면, 비선형 흡수의 반응시간은 10 ns보다 빠른 것으로 추정하였다. Intensity-dependent optical nonlinear refractive index n2 and absorption coefficient β have been measured by top-hat beam Z-scan technique. Top-hat beam transfomed from gauss beam is used to improve the sensitivity of Z-scan measurement. We adoped a graphical method which allows straightforward determination of both real and imaginary components of χ(3) from Z-scan data. The nonlinear refractive index n2 is constant, indicating a third order process, but nonlinear absorption coefficient β increases with intensity, indicating a fifth order process. Using time resolved double pulse Z-scan measurement, we estimated the response time which is related with large optical nonlinearities in the nanosecond (ns) time scale. We found that the time response of nonlinear refraction is slower than 10 ns whereas the nonlinear absorption is fatter than 10 ns.
선박용 유배출 감시 장치(ODME)를 위한 유분 농도계 설계
손교훈,이승희,김재형 國立 昌原大學校 産業技術硏究所 1998 産技硏論文集 Vol.12 No.-
본 논문에서는 태형 탱커선의 의무 장비인 유배출 감시 장비 (Oil Discharge Monitoring Equipment)를 위한 유분 농도계의 설계에 대하여 연구하였다. ODME는 국제해사기구(IMO)에서 규정된 ton 이상의 대형 선박에 의무적으로 설치하도록 규정하고 있으며 이는 날로 심각해지는 해양 오염을 방지하는데 목적이 있다. ODME의 구성요소 중 가장 중요한 것은 유분 농도계이며 이는 선박에서 배출되는 물에 포함된 유 성분을 ppm 단위로 계측하는 것이다. 본 연구에서는 선박에서 사용이 용이한 산란방식의 유분 농도계의 설게에 대한 농도 계산 알고리즘에 대하여 고찰하였으며 0~100ppm 범위에서 ±5%의 오차 이내로 측정이 가능함을 보였다. 이는 IMO의 규격에 만족하는 수치이다.