http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
광디스크 드라이브 공기베어링 슬라이더의 형상민감도 해석
김현기,장혁,김광선,임경화,Kim, Hyun-Ki,Jang, Hyuk,Kim, Kwang-Sun,Lim, Kyong-Hwa 한국마이크로전자및패키징학회 2000 마이크로전자 및 패키징학회지 Vol.7 No.4
고성능과 고속화의 면에서 광저장장치의 관심은 상당히 높다. 그러나 하드디스크와 비교하여 광저장장치는 임의의 데이터에 대한 탐색속도가 매우 늦다. 따라서, 광저장장치에서의 새로운 형태의 연구가 필요하다. 본 연구는 하드디스크 장치와 유사한 스윔 암 구동기를 사용한 광저장장치의 공기베어링의 특성에 관해 연구하였다. 광저장장치에서 요구되어지는 최적의 슬라이더 형상을 구하기 위하여 공기 베어링면의 형상변화에 따른 부상상태에 관한 민감도를 연구하였다. The optical storage device has recently experienced significant improvements, especially for the aspects of high capacity and fast transfer rate. However, it is the fact that the optical storage device has the lower access time for the randomly scattered data compared to the hard disk drives. It is, therefore, necessary to develop a new type of optical storage system. In this study, we investigate the air bearing characteristics for the optical disk drives which have the swing arm actuator similar to the hard disk drives. Considering the requirements of the optical disk drives, we parameterize the shape of the air bearing surface and investigate its sensitivity to the flying characteristics for further optimized design outputs.
황소민,김장혁,김형도,정용휘,김홍일,Hwang, So-Min,Kim, Jang Hyuk,Kim, Hyung-Do,Jung, Yong-Hui,Kim, Hong-Il 대한두개안면성형외과학회 2013 Archives of Craniofacial Surgery Vol.14 No.2
Background: Among facial fractures, nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture take a large portion. Among surgical operations for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture, closed reduction has been generally used but, unlike open reduction, there is a problem in evaluating its accuracy of reduction. Methods: An assessment was made from October 2011 until April 2013 prospectively on 37 patients. For all the operations, closed reductions were executed in a conventional way and simultaneously using C-Arm to verify the reduction of fractures. Two images of plain radiography, one taken before operation and another one taken one day after the operation, were compared. After obtaining images of plain radiography using C-Arm immediately after the correction upon operation, they were compared with the images of plain radiography taken one day after the operation. Results: The fracture reductions of 26 patients among 27 nasal fracture patients were satisfactory but one patient showed a marginal overcorrection of less than 1 mm. The fracture reductions of 7 patients among 8 zygomatic arch fracture patients were satisfactory but one patient showed a marginal undercorrection of less than 2 mm. All of two mandibular subcondyle fracture patients showed less than 2 mm undercorrection. Conclusion: Closed reduction guided by C-Arm for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture was clinically useful because it could make a real-time assessment on fractured areas and add immediate corrections during the operation.