http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
수직 환상관내 반류 공기-물 유동에서 직접분사방식에 따른 플러딩 시작점 특성
이상천,신익호,이상무,정모,김동수,장원표,Lee, S.C.,Shin, I.H.,Lee, S.M.,Chung, M.,Kim, D.S.,Chang, W.P. 대한기계학회 1996 大韓機械學會論文集B Vol.20 No.1
An experimental work was conducted to investigate the characteristics of the onset of flooding in vertical annuli with a direct injection mode using air and water. The onset of flooding was determined by means of pressure drop measurement while the air velocity was increased gradually under fixed liquid flow rates. Data of the onset of flooding were collected for various combinations of the tube size and the nozzle number. A theoretical analysis of the onset of flooding was also performed based on an envelope theory. The result shows that the onset of flooding in small-scale annuli can be predicted relatively well by the theory. A modified Wallis parameter was used to investigate the scaling effect of flooding phenomena in the annuli, indicating a relatively reasonable result. The number of nozzle has no effect on the flooding velocity when liquid was injected through 2, 3, 4 and 6 nozzles but the initiation of flooding was significantly expedited when 12 nozzles were employed for liquid injection.
이상천,이정표,김중엽,Lee, S.C.,Lee, J.P.,Kim, J.Y. 대한설비공학회 1988 설비저널 Vol.17 No.4
The characteristics of flow pattern transitions in a horizontal cocurrent gas-liquid flow have been investigated by means of a statistical analysis of instantaneous pressure drop curves at an orifice. The dimensionless intensity of pressure drop fluctuation shows a sudden change during the course of flow transitions, indicating that it may be a good measure to identify the flow regime transitions. The probability density function of the curves feature a unique pattern depending upon the flow regimes and the statistical properties of the PDF also have particular ranges for each flow regime. In conclusion, the statistical analysis of instantaneous pressure drops may be a powerful tool for predicting the flow regime transitions.
안명천,최상대,주호완,김기왕,황도근,이장로,이상석,Ahn, M.C.,Choi, S.D.,Joo, H.W.,Kim, G.W.,Hwang, D.G.,Rhee, J.R.,Lee, S.S. 한국자기학회 2007 韓國磁氣學會誌 Vol.17 No.4
어레이(away) 자성센서 개발을 위해 고진공 스퍼터링 증착장비를 이용하여 스펙큘러형(specular type) Glass/Ta(5)/NiFe(7)/IrMn(10)/NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; CMR-SV)박막을 제작하였다. 다층박막 시료를 $20{\times}80{\mu}m^2$의 미세 활성영역을 가진 15개 어레이를 $8{\times}8mm^2$ 영역 내에 최적화한 제작 조건으로 광 리소그래피 패터닝 하였다. Cu를 증착하여 만든 2단자 전극법으로 측정한 자성특성은 15개 모든 소자들이 균일한 자기저항특성을 나타내었고, 5 Oe 근방에서 가장 민감한 자기저항비 자장민감도와 출력전압들은 각각 0.5%/Oe, ${\triangle}$V: 3.9 mV이었다. 형상자기이방성이 적용된 상부 자유층 $CoFe/O_2/NiFe$층은 하부 고정 자성층 $IrMn/NiFe/O_2/CoFe$층 자화 용이축과 직교하였다. 측정시 인가전류 값을 각각 1 mA에서 10 mA까지 인가하였을 때 출력 작동 전압 값은 균일하게 증가하였으며, 자장감응도도 거의 일정하여 미세 외부자장에 민감한 나노자성소자로서 좋은 특성을 띠었다. To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.
순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별
이상천,이정표,김중엽,Lee, S.C.,Lee, J.P.,Kim, J.Y. 대한설비공학회 1988 설비저널 Vol.17 No.5
Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.
이상천,한용운,신현승,이형돈,Lee, S.C.,Han, Y.O.,Shin, H.S.,Lee, H.D. 대한설비공학회 1993 설비공학 논문집 Vol.5 No.1
An experiment has been carried out to identify flow patterns in a horizontal condensing flow with R-113. Characteristics of flow patterns were determined based upon a statistical analysis of differential pressure fluctuations at an orifice. The probability density function and power spectral density function of instantaneous pressure drop curves for various flow conditions were obtained. In comparison to the results of air-water flows, the flow patterns in a condensing flow such as annular, wavy, slug and plug could be identified. The experimental data determined by this technique were compared with the flow pattern maps suggested by other investigators. The result indicates that the statistical characteristics of differential pressure fluctuations at an orifice may be a useful tool for identifying flow patterns both in condensing flows and in adiabatic two-phase flows.