http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
오한빈,문봉진,Hwangbo Song,Jungeun Bae 사단법인 한국질량분석학회 2016 Mass spectrometry letters Vol.7 No.4
To determine the influence of the cationization agent on the collision activated dissociation (CAD) fragmentation behavior of oligosaccharides, the CAD spectra of the singly protonated, sodiated oligosaccharides and singly sodiated and dibenzo-18-crown-6 ether conjugated oligosaccharides were carefully compared. Each of these three different species showed quite different fragmentation spectra. The comparison of singly protonated and sodiated oligosaccharide CAD spectra revealed that different cationization agents affected the cationization agent adduction sites as well as the fragmentation sites within the oligosaccharides. When the mobility of Na+ was limited by the dibenzo-18-crown-6 ether encapsulation agent, the examined linear oligosaccharides showed fragmentation patterns quite different from the unmodified ones. For the dibenzo-18-crown-6 ether conjugated oligosaccharides, the charge-remote fragmentation pathways were more likely to be activated than the chargedirected pathways. This work demonstrates that dibenzo-18-crown-6 ether conjugation can potentially provide a route to selectively activate the charge-remote fragmentation pathways, albeit to a limited extent, in tandem mass spectrometry studies.
인공지능 기법을 이용한 질량분석 스펙트럼 해석과 신종 화학물질 스크리닝 기법
오한빈(Han Bin Oh) 환경독성보건학회 2021 한국독성학회 심포지움 및 학술발표회 Vol.2021 No.5
우리는 새로운 물질들이 수없이 합성되고 있는 세상에 살고 있습니다. 환경이나 제품에 쓰이는 화학물질들을 분석하는데 있어서 새롭게 합성되는 물질은 정성 분석이 매우 어렵습니다. 새로운 물질을 정성 분석할 때에 주로 쓰이는 방법은 환경매질이나 제품내 화합물들을 분리하고, 이들에 대한 질량분석 스펙트럼 및 탠덤 질량분석 스펙트럼을 얻어, 데이터베이스 상의 자료와 비교하는 접근법인데, 이 접근법이 새로운 물질의 경우 적용이 불가능하기 때문입니다. 이런 문제를 어떻게 풀 수 있을까 하는 노력의 일환으로, 대상이 좁혀진 화학군에 경우에 미지의 화학물에 대한 정성 분석에 인공지능기법 및 혼성 유사성 검색(Hybrid Similarity Search)이라는 알고리즘을 통해 가능함을 보여준 연구결과를 발표하고자 합니다. 본 발표에서 예로써 발기부전치료 부정 의약품과 마약류에 대한 결과를 보여 드리고자 하는데, 이 방법은 환경분석의 경우에도 마찬가지원리로 적용 가능합니다. 예를 들어, 발기부전치료제들은 비교적 비슷한 화학구조를 갖고 있습니다. 비슷한 화학구조로 인해서 그들의 탠덤 질량분석 스펙트럼들 역시 비슷한 특성을 갖고 있습니다. 하지만, 이것들이 사람들의 인지능력으로는 쉽게 규칙성을 찾기 어려운 경우가 대부분입니다. 이 문제를 해결하기 위해 많은 발기부전치료제들의 탠덤 질량분석 스펙트럼들을 머신러닝 기법을 통해 훈련시켜 소위 인공지능 모델을 만들고, 이를 미지의 물질에 대한 탠덤 질량분석 스펙트럼에 적용한 결과, 매우 정확하게 미지의 물질이 발기부전치료제인지를 확인할 수 있었습니다. 하지만, 이 정보만으로는 부족하여 미지의 물질과 가장 유사한 분자와 그 분자와의 차이를 확인하기 위해서는 기존의 유사도 검색기법을 변형한 혼성 유사도 검색 알고리즘을 채택하여 분석한 결과 미지 분자에 대한 상세한 정보를 알 수 있었습니다.
Do-It-Yourself (DIY) manufacture of a Nano-LC MALDI spotter robot using 3D printing technology
이재웅,오한빈 한국분석과학회 2017 분석과학 Vol.30 No.4
In the era of the forth Industrial Revolution, open source code and open source hardware have gained much attention. In particular, 3D printing technology is expanding into the realms of classical science, technology and our daily lives. Relatedly, in the present study, we demonstrate the manufacture of a nano-LC MALDI spotter robot using 3D printing technology. The parts of the spotter robot were either made using a 3D printer or purchased as 3D printer parts from the 3D printer online market, so that anyone can make the robot without a deep knowledge of engineering or electronics, i.e., DIY (do-it-yourself) product. In the nano-LC MALDI spotter, the nano-LC eluent and MALDI matrix were mixed in a T-union and discharged from the capillary outlet. The eluent and matrix mixture could be spotted onto the movable MALDI plate. The MALDI plate was designed to translate in a two-dimensional space (xy plane), which was enabled by the movements of two stepper motors. In the paper, all computer-aided design (CAD) files for the parts and operation software are provided to help the reader manufacture their own spotter robot.
이선영,김권성,오한빈,홍종기,강덕진 사단법인 한국질량분석학회 2017 Mass spectrometry letters Vol.8 No.3
In clinical diagnosis, it’s well known that the abnormal level of uric acid (UA) in human body is implicated in diverse human diseases, for instance, chronic heart failure, gouty arthritis, diabetes, and so on. As a primary method, an isotope dilution mass spectrometry (IDMS) has been used to obtain the accurate quantity of UA in blood or serum and also develop the certifi-cated reference material (CRM) so as to provide a SI-traceability to clinical laboratories. Due to the low solubility of UA in water, an ammonium hydroxide (NH 4 OH) has been considered as a promising solvent to increase the solubility of UA that enables the preparation of both UA and its isotope standard solution for next IDMS-based absolute quantification. But, because of using this NH 4 OH solvent, it gives rise to the unwanted degradation of UA. In this study, we sought to optimize condition for the stability of UA in NH 4 OH solution by varying the mole ratios of UA to NH 4 OH, followed by ID-LC-MRM analysis. In addi-tion, we also inspected minutely the effect of the storage temperatures. Additionally, we also performed the quantitative analysis of UA in the KRISS serum certificated reference material (CRM, 111-01-02A) with diverse mixing ratios of UA to NH 4 OH and then compared those values to its certification value. Based on our experiments, adjusting the mole ratio of 1/2 (UA/NH 4 OH) with the storage temperature of -20 o C is an effective way to secure both the solubility and stability of UA in NH 4 OH solution for next IDMS-based quantification of UA in serum.