건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구- 실물규모 침대 매트리스 화재시험 중심으로-
서보열,장우빈,박계원,홍원화 한국화재소방학회 2018 한국화재소방학회논문지 Vol.32 No.6
To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space,a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets(KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), themaximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in thetest room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement timeaccording to the test location was confirmed. 건축물 구획공간에 따른 화재성상 및 열방출율을 측정하기 위하여 실물규모 침대 매트리스의 표준화재시험방법(KS F ISO 12949 : 2011)으로 화재시험을 수행하였다. 개방형공간과 구획공간 모두 버너착화 후 초기 약 3분까지는유사한 화재성장의 경향을 보이는 것으로 확인되었다. 3분후 구획공간에서의 열방출율이 개방형 공간보다 증가되어높은 것으로 확인되었다. 침대 매트리스(SS)의 경우, 개방형 공간에서의 최대열방출율은 735 kW이며, 구획공간에서의 최대열방출율은 992 kW 로 측정되었다. 침대 매트리스(Q)의 경우 3분후 구획공간에서의 열방출율이 개방형 공간보다 급격하게 증가되는 것으로 확인되었다. 개방형 공간에서의 최대열방출율은 1,087 kW, 이 때의 측정시간은 346s 이며, 구획공간에서의 최대열방출율은 2,127 kW, 이때의 측정시간은 287 s 측정되어 구획공간에 따른 최대열방출율 및 측정시간의 차이가 확인되었다.
서보열,임동찬 한국공업화학회 2014 한국공업화학회 연구논문 초록집 Vol.2014 No.1
A simple low temperature for sponteneus formation of nanoripples on ZnO thin films was developed, and these nanostructured ZnO films were used as hole-blocking layer in inverted organic solar cells, Moreover, power conversion efficiency (PCE) vary depending on the temperature of heat treatment. Among various temperatures of heat treatment 180 oC for 10 minute resulted in the best photovoltaic performance of the organic solar cell consisting of a stack of indium tin oxide/ZnO/PTB7 (polythienothiophene-co-benzodithiophenes 7) mixed with PC70BM (phenyl-C71-butyric acid methyl ester) /Ag. The PCE of inverted organic solar cells consisting of with 0.5M ZnO nanoripples (~8.4%) was higher than other heat treatmented ZnO films. Existence of nanoripples on ZnO results in a higher contact area between ZnO and active layer, leading to an enhanced photovoltaic performance. futhermore, existence of amine in the low temperature proceed ZnO film lead to control the band gap of ZnO. finally our fabricated OPV is improved in two aspects.
냉각프레임 설치 유무에 따른 스프링 침대 매트리스의화재성상에 관한 연구
서보열,박계원,홍원화 한국화재소방학회 2018 한국화재소방학회논문지 Vol.32 No.2
To improve the fire safety of spring bed mattress, a cooling frame including cooling material (water) was made and acooling frame was installed under the bed mattress or between the bed mattress and bed mattress base; fire tests (real scale)were conducted with or without a cooling frame. Similar fire behavior was observed at the beginning of the test(approximately 3 minutes). Subsequently, rapid fire growth in the mattress without a cooling frame, but with a cooling frame,the decline progressed without growth. The flame spread on the top surface of the bed mattress was similar in the semicirculardirection, and the average flame speed velocity was analyzed at approximately 0.005 m/s. The maximum flame height wasfound to be approximately 2.7 m without a cooling frame, and approximately 1.8 m with a cooling frame installed. In addition,the maximum heat release rate was measured to be approximately 740 kW without a cooling frame, and approximately 400kW with a cooling frame installed. As a result, the flame height and heat release rate were reduced when the bed mattresswas fired through the installed cooling frame. 스프링 침대 매트리스의 화재안전성을 향상시키기 위한 방안으로 냉각재료(물)을 포함한 냉각프레임을 제작하여침대 매트리스 아래 또는 침대 매트리스와 침대 매트리스 받침대 사이부분에 냉각프레임을 설치하여 냉각프레임 설치 유무에 따른 실물규모 화재시험을 실시하였다. 시험 초기(약 3분)에는 비슷한 화재성상을 보이나 이후에는 냉각프레임이 없는 경우는 급격한 화재성장이 확인 되었으며, 냉각프레임이 있는 경우는 성장되지 않고 쇠퇴가 진행되었다. 침대 매트리스 상단표면에서의 화염전파는 반원방향으로 유사하게 진행되었으며, 평균 화염전파속도는 약 0.005m/s 분석되었다. 최대화염높이는 냉각프레임이 없는 경우 약 2.7 m, 냉각프레임이 설치된 경우 약 1.8 m 로 분석되었다. 또한 최대열방출율(Heat release rate)은 냉각프레임이 없는 경우는 약 740 kW, 냉각프레임이 설치된 경우는 약400 kW 측정되었다. 결과적으로 냉각프레임 설치를 통해 침대 매트리스 화재시 화염높이 및 열방출율이 저감되는것으로 확인되었다.