폴리우레탄 코팅장갑내의 DMF 함량 및 피부노출에 대한 평가
박해동,노지원 한국산업보건학회 2022 한국산업보건학회지 Vol.32 No.2
Objectives: The purpose of this study is to analyze the content of N,N-dimethylformamide(DMF) in polyurethane coated gloves(PU-gloves) and to assess the dermal exposure generated by wearing them. Methods: We analyzed the concentrations of DMF in 12 gloves by EN16778 standard. The samples cut into pieces of about 10 by 10 mm and extracted with methanol in flask in an ultrasonic bath at 70℃. An aliquot of the extract is analyzed with GC-MS. The dose of dermal exposure was calculated by ECETOC TRA consumer 3.1 and compared with derived no effect level(DNEL) for systemic effects due to long term exposure by workers. The extracted amount of DMF by saline solution was compared with that by EN16778 standard. Results: The mean concentration of DMF in PU-gloves was 1,377 ㎎/㎏(range 13~3,948 ㎎/㎏). The concentration of DMF showed significantly differences by packing type, manufacturer, and price(p<0.05). The dose of dermal exposure was 0.0007~0.572 ㎎/㎏ body weight/day when the DMF content was 10~4,000 ㎎/㎏. The DMF extracted by saline solution was around 11% for 8 hours. Conclusions: The risk of dermal exposure due to the residual DMF in the PU-gloves was not signifiant. But, the limit of 1,000 ㎎/㎏ in PU-gloves can be recommended for international standard and trading systems.
The Quality Control Program for Industrial Hygiene Laboratories in Korea
박해동,정은교,김기웅 한국산업안전보건공단 산업안전보건연구원 2017 Safety and health at work Vol.8 No.3
In 1992, the quality control program was introduced in Republic of Korea to improve the reliability of the work environment monitoring, which was introduced in the 1980s. The commission entrusted by the Ministry of Employment and Labor, the Occupational Safety and Health Research Institute has conducted the program for industrial hygiene laboratories including designated monitoring institutions and spontaneously participating agencies. The number of institutions that participated in the program has increased from 30 to 161. The initial conformance ratio in the participants was 43% (organic solvents) and 52% (metals). Thereafter, the conformance ratio increased rapidly and it has remained in a stable state at more than 89% since 1996. As subject materials, 13 kinds of organic solvents and 7 kinds of metals were used. To improve the capability of measurement and analysis of private institutions, educational courses were conducted annually. An assessment at the actual sites of participants was additionally introduced into the program in 2013. Thus, the program turned into a system that administrates the overall process of participants. For the future, the scope of target materials will be extended through additional items. Thus, the reliability of the results of the work environment monitoring is expected to increase accordingly.
일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가
박해동,박현희,신정아,김태호,Park, Hae-Dong,Park, Hyun-Hee,Shin, Jung-Ah,Kim, Tae-Ho 한국환경보건학회 2010 한국환경보건학회지 Vol.36 No.5
The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.