http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
일부 농촌주민에서 Alcohol Use Disorders Identification Test를 이용한 위험 및 유해 음주율 조사
김형수,이건세,김청식,김기옥,장성훈,Kim, Hyeong-Su,Lee, Kun-Sei,Kim, Cheong-Sik,Kim, Ki-Ock,Chang, Soung-Hoon 대한예방의학회 2001 예방의학회지 Vol.34 No.3
Objectives : To investigate the prevalence of hazardous and harmful alcohol use, which are a subthreshold of alcohol related disorders, Methods : Direct-interview questionnaires to 1,183 rural persons (489 male, 694 female) were conducted in Chungju-city from July 2 to 20, 1998. As a screening instrument, the alcohol use disorders identification test (AUDIT) was used. Results : The prevalence of alcohol use was 41.7%. In males, it was 66.3% and in females, it was 24.4%. The mean of the AUDIT score of males and females was 13.2 and 5.6, respectively. As WHO guideline, the prevalence of hazardous alcohol use in males and females was 80.3% and 20.7%, respectively. This suggests that the prevalence of 'hazardous drinking' and 'harmful drinking' was 45.4% and 29.3% for males and 1.2% and 2.4% for females, respectively. Conclusions : This study presented the prevalence of hazardous and harmful drinking of a rural population in Korea and reviewed those health problems. Further evaluation to detect and treat lower alcoholic drinkers is recommended.
부여 취수장의 $NH_3-N$자료에 대한 평균 및 분산추정
김형수,정건희,김응석,김중훈,Kim, Hyeong-Su,Jeong, Geon-Hui,Kim, Eung-Seok,Kim, Jung-Hun 한국수자원학회 2001 한국수자원학회논문집 Vol.34 No.4
실험 또는 계측에 의해 관측된 관측치들은 종종 어떤 기준치 이하의 작은 값들이 기록되는데, 이들 기준치 이하의 값들이 크기는 미소할지라도 평균이나 분산 추정시 왜곡된 결과를 줄 수 있다. 그러나 우리 나라에서는 관측오차로 간주하여 N.D.(Not Detected)로 처리하는 것을 관례로 하고 있어 미소치들이 기록되지 않고 있다. EK라서 본 연구에서는 부여 취수장의 암모니아성 질소(NH$_3$-N)자료가 크기에 따라 분표형이 다름을 조사하고 그 분포를 구별할 수 있는 기준치와 기준치 이하의 자료들에 대한 평균과 분산 추정시 가장 적절한 기법을 찾고자 하였다. 즉, 기준치 이하의 값들과 이상의 값들을 구분하여 평균과 분산을 위한 적절한 기법을 선정하여 추정하였다. 분석 결과 부여취사장의 자료는 편기 수정된 최우도(Bias Corrected ML)법이 가장 적합한 것으로 결정되었으며, 시행착오법에 의하여 기준치를 설정하였다. Sometimes the observed data is too small to discriminate it from noise of the instrument. Say, the data can be recorded as below DL(Detection Level) value. Even though the data below Detection Level(BDL) is small vague, it can be resulted in wrong estimates for mean and variance. However, in practice, the BDL data is generally eliminated as N.D. (Not Detected) and do not record it in Korea. This study investigates the distributions according to the data values of ammonia concentration (NH$_3$-N) in Puyeo intake. Also we try to find out DL value and an appropriate method for the estimations of mean and variance of BDL values that can be discriminate the distributions. The DL is estimated by trial and error method. The appropriate method for the estimations of mean and variance of above the detection level(ADL)and BDL dada sets is selected, and the mean and variance are estimated. As a result, it is found that the Bias Corrected Maximum Likelihood Estimator is the most accurate method for NH$_3$-N in Puyeo intake.
분말사출성형 시 분말 혼합체의 유동성 시뮬레이션을 통한 투광성 알루미나 소결체의 특성 연구
김형수,변종민,김세훈,김영도,Kim, Hyung Soo,Byun, Jong Min,Kim, Se Hoon,Kim, Young Do 한국분말야금학회 2014 한국분말재료학회지 (KPMI) Vol.21 No.3
Translucent alumina is a potential candidate for high temperature application as a replacement of the glass or polymer. Recently, due to the increasing demand of high power light emitting diode (LED), there is a growing interest in the translucent alumina. Since the translucent property is very sensitive to the internal defect, such as voids inside or abnormal grain growth of sintered alumina, it is important to fabricate the defect-free product through the fabrication process. Powder injection molding (PIM) has been commonly applied for the fabrication of complex shaped products. Among the many parameters of PIM, the flowability of powder/binder mixture becomes more significant especially for the shape of the cavity with thin thickness. Two different positions of the gate were applied during PIM using the disc type of die. The binder was removed by solvent extraction method and the brown compact was sintered at $1750^{\circ}C$ for 3 hours in a vacuum. The flowability was also simulated using moldflow (MPI 6.0) with two different types of gate. The effect of the flowability of powder/binder mixture on the microstructure of the sintered specimen was studied with the analysis of the simulation result.
김형수,박춘호,배기광,정상태,최창범,Kim, Hyeong-Su,Park, Chun-Ho,Bae, Gi-Gwang,Jeong, Sang-Tae,Choe, Chang-Beom 한국재료학회 1993 한국재료학회지 Vol.3 No.3
3원계 U-Ce-O산화물의 소결거동을 연구하기 위하여 $UO_2$ 및 $CeO_2$분말을 ball-mill 방법으로 혼합한 (U, Ce)$O_2$의 영향이고, 나중에 나타나는 극대점은 $CeO_2$의 영향 때문이다. 또한 $Ceo_{2}$함량이 증가할수록 소결이 지연됨을 알수 있었다. 동일한 10wt. % $CeO_2$함량에서, 4시간동안 ball-milling을 하였을때가 소결속도는 가장 빨랐다. In order to study the sintering kinetics of the ternery system, U-Ce-O, its shrinkage rate with time and temperature at the Ar atmoshpere were measured by using the dilatometer. At the sintering kinetics of U-Ce-O, sintering rate curve revealed bimodal and the first extreme point at bimodal curve was affected by the $UO_2$ the second one was due to the $CeO_2$. The sintering of $(U, Ce)O_2$ was delayed as increasing the $CeO_2$. At the same lOwt. % content, the highest sintering rate was observed at the $(U, Ce)O_2$ sample ball-milled for 4 hours.
Laser Doppler Flowmetry를 이용한 치은혈류량에 관한 연구
김형수,이장희,송형근,김병옥,한경윤,Kim, Hyung Soo,Lee, Zang-Hee,Song, Hyung-Geun,Kim, Byung-Ock,Han, Kyung-Yoon 대한치주과학회 1998 Journal of Periodontal & Implant Science Vol.28 No.2
The periodontal health has been evaluated clinically by various epidemiological indices, and in researches by measurement of gingival crevicular fluid. Laser Doppler flowmetry is a reliable and objective method that allows immediate measurement of erythrocyte flux in approximately one cubic mm of the capillary bed without disturbing the tissues. The purpose of the present study was to determine whether human gingival blood flow was different according to measuring area, measuring time, and sex or not. Forty volunteers with good general and periodontal health, aged early twenties and unmarried, were selected. Laser Doppler flowmetry($floLAB^{(R)}$, Moor Instruments Ltd., England) was applied to measure the gingival blood flow of marginal gingiva, interdental papilla, attached gingiva and alveolar mucosa. The blood flow of interdental papilla was measured at 9-10 AM, 1-2 PM, and 5-6 PM. The difference of blood flow according to measuring area and measuring time was statistically analyzed by one way AOVA and Dunkan test, and the difference of blood flow between men and women was statistically analyzed by t-test. (1) Mean blood flow was significantly higher in alveolar mucosa than in the gingiva(p<0.05), and there was no significant difference in blood flow between marginal gingiva and interdental papilla(p>0.1). (2) Mean blood flow was significantly higher at 5-6 PM than at 9-10 AM and 1-2 PM(p<0.05). But there was no significant difference in gingival blood flow between 9-10 AM and 1-2 PM(p>0.1). (3) There was no significant difference in gingival blood flow between men and women(p>0.1). The above results suggest that the measurment of gingival blood flow using laser Doppler flowmetry may be clinically applicable to early determination of gingival inflammation and evaluation of healing status, but further studies are necessary to standardize and simplify the measuring procedure.