http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김봉환 ( B. H. Kim ),김경훈 ( K. H. Kim ) 한국분무공학회 2002 한국액체미립화학회지 Vol.7 No.2
N/A According to the improvement of PC performance, it is expected that calorific value, which causes PC to malfunction, is increased. Therefore, the development of new cooling system is recently required. As the method to solve this problem, we applied loop heat pipe to PC cooling system. The advantage of the loop heat pipe is that it has a small size, light weight, simple shape, long life and it has a good performance on heat transfer, no-noise, wide range of applicable temperature and no supply of power from the outside. It is confirmed that loop heat pipe reduces thermal resistance and has a good performance on PC cooling.
ENTERIC COLIBACILLOSIS IN PIGS. A REVIEW
B. H. Kim(金鳳煥) 한국예방수의학회 1978 예방수의학회지 Vol.2 No.1
病原性 大腸菌의 感染에 依한 돼지의 大腸菌症(Enteric Colibacillosis)은 離乳前後 새끼돼지 損失의 약 반을 차지할 만큼 重要한 疾病의 하나이다. 病原性 大腸菌症은 臨床症狀 및 發病機轉에 따라 病原性大腸菌 설사병과 浮腫病으로 大別할 수 있다. 大腸菌 설사병의 發生은 새끼돼지의 年齡과 密接한 關係가 있다. 이것은 어미돼지의 初乳 및 젖을 通하여 받은 母體移行 抗體의 消長 및 새끼돼지 自信의 防禦能力, 環境 및 飼養條件에 따른 스트레스등의 複合的인 要因으로 因하여 病原性 大腸菌의 感染 增殖이 用易한 年齡에 發生하며 主로 生後 1-4日頃의 어린돼지에 多發하는 ‘新生仔豚설사’, 母體移行 抗體가 거의 消失할 때인 生後 2-3週頃에 發生하는 ‘3週齡 설사병’과 離乳後 約 一週쯤에 好發하는 ‘離乳仔豚 설사병’ 등 3가지 類型으로 區別할 수 있다.
실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발
이봉재,김봉환,장시영,김종수,Lee, B.J.,Kim, B.H.,Chang, S.Y.,Kim, J.S. 대한방사선방어학회 2000 방사선방어학회지 Vol.25 No.4
실리콘 PIN 다이오드 검출기를 이용하여 전자선량계(PED)를 설계 및 제작하고, 전자신호회로의 성능과 방사선 검출 반응특성을 평가하였다. 전자회로의 성능검사에서는 방사선에 의한 검출기의 신호가 신호처리회로에서 양호하게 출력되었으며, $^{137}Cs$ 감마 방사선을 이용한 방사선조사 시험결과 선량계의 반응도 및 분산계수는 각각 1.85 cps/$Gy{\cdot}h^{-1}$ 및 19.3%로 측정되어 전자선량제의 성능기준을 만족하는 것으로 나타났다. 본 전자선량계의 시작품은 향후 전자회로의 성능향상과 작동 프로그램을 보완 및 개선함으로써 개인 방사선 모니터링에 활용될 것으로 기대된다. A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.
Purified Protein Derivative Tuberculin의 생산시험
김정규,김봉환,이현수,전윤성,Kim, J.K.,Kim, B.H.,Lee, H.S.,Jeon, Y.S. 대한수의학회 1970 大韓獸醫學會誌 Vol.10 No.2
For the establishment of more reliable and applicable methods for the diagnosis of tuberculosis in dairy cattle, avian- and mammalian PPD tuberculins were prepared according to the methods of Weybridge purified protein derivative tuberculins with minor modifications. PPD tuberculin was not only a very pure product from a chemical standpoint, but also one which, judged on the basis of laboratory results, was likely to be more potent and reliable than HCSM tuberculin.