RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        現行 稅法上 更正請求制度에 관한 硏究

        정지선,박정우,육윤복 한국기업법학회 2004 企業法硏究 Vol.16 No.-

        Texes are imposed through formation and decision of tax payment. There are government imposition way and self-assessment way on the decision method of tax payment, and most taxes are confirmed by self-assessment way because exuviating in traditional decision method in modern taxes. Tax payment by self-assessment system is primary decision method of the tax payer because he knows his assessment well, and reserve decision right of taxation government office to secondary or complemental position. These tax payment system by self-assessment is accepted in the U.S.A. traditionally, and say that is own imposition system in meaning that tax payment establishes oneself standard of assessment and amount of a tax. It is most situation, indeed, taking tax payment by self-assessment way individual income tax, corporate income tax, education tax, traffic tax and etc, in Korean tax system. These self-assessment system can be thought that is suitable to tax payment usage which is democratic because it establishes own tax amount, but when tax return is reported overmuch by mistake of statute etc, it creates the problem to relieve very hardly. So, when taxpayer files overpaid taxes or littleness deficit amount of money, we introduced the claim system for reassessment since 1995 to correct this in case do. This claim system for reassessment has various kinds of problems because the enforcement time is short up to now and the research is not gone abuzz. Therefore, this research examines problems of current the claim system for reassessment and compares with foreign tax laws and groped the improvement way. The improvement ways of current claim system for reassessment are as following if they list important things. First, it is problems about extension of claim period for reassessment. Current claim period for reassessment is that is within 2 years from the date the return was filed in general claim for reassessment's case, and in the case of claim for reassessment by after flare reason arrive within 2 months from a day that reason happens. This can be thought that the period is insufficient in right relief because correspond to short term. Therefore, in general claim for reassessment's case, the period must be extended within 5 years from the date the return was filed, and must be extended within 6 months from a day that reason happens encountering in the claim for reassessment by reason that is after flare. Second, it is problem about unclearable nature of reason in the claim for reassessment by reason that is after flare. Currently, in the case of the claim for reassessment by reason after flare, a analytic part that become an issue is when it cancels contract by inevitable reason, whether correspond to the reassessment claim's subject, and when it correspond to the reassessment claim's subject, inevitable reason usually intends cancellation of sum, that is deciding each differently about the reassessment claim's target in reason after flare time at time of cancellation of sum in case of transfer income tax, gift tax and acquisition tax. Third, it is problem by pleading not guilty of reassessment claim system in local tax law. Current local tax is recognizing right redress through correction report, application and so on. But the claim system for reassessment is not recognized by local tax. As such result, when taxpayer overpays local taxes through mistake, the method of the right relief is blocked effectively in that case and is implying various kinds irrational standpoint being real condition. Therefore, local tax law have to introduce not only general claim system for reassessment but also reassessment claim system by reason after flare as soon as possible.

      • KCI등재후보

        대유행인플루엔자 대비를 위한 의료기관-바탕 탁상훈련 : 고안 및 평가

        설희윤,김지량,권보란,목정하,이선희,곽임수,정진우,김정수,고옥배,조은희,김성순,신상숙,이상원 대한감염학회 2008 감염과 화학요법 Vol.40 No.2

        목적 : 의료기관의 범유행 인플루엔자에 대한 효과적인 대비를 위한 훈련방법으로서 의료기관-바탕 탁상훈련 (hospital based tabletop exercise)의 유용성과 순응도를 평가하기 위해서 시행되었다. 재료 및 방법 : 탁상 훈련은 부산대학교 병원에서 시행되었으며 병원의 주요의사결정권자 및 주요부서 대표자, 실무자 42명이 지휘부, 진료부, 지원부 3그룹으로 나뉘어 훈련에 참가하였다 탁상훈련의 시나리오는 의료기관의 자체 훈련을 위해서 고안하였으며 현재 동남아에서 유행하고 있는 H5N1 인플루엔자가 국내에 처음으로 유입되어 확산되는 과정에서 의료기관에서 발생할 수 있는 상황을 3가지 모듈로 구성하였다. 훈련 평가는 훈련 전후에 각각 익명의 설문조사를 시행하였다. 결과 : 훈련에 초청된 참여자 42명 중 37명(88%)이 실제 당일 훈련에 참여하였다. 훈련에 참여한 37명의 직원 중에서 훈련 전 시행한 설문에 27명(73%)이 응답하였다. 훈련 전 정가에서는 훈련을 통해 획득하고 싶은 지식이나 기술의 우선 순위를 물었으며, 참여자들이 가장 중요하다고 생각하는 항목은 대유행인플루엔자 바이러스에 대한 지식 향상 22%, 병원 각 부서가 취해야 할 계획 및 의사소통과 관련된 지식 향상 19%, 지역사회 병원들 간의 상호협력을 향상시킬 전략 계발이 19%이었다. 그룹토의 동안에는 환자의 조기 발견 이후 대응에 대한 토론이 많았지만, 구체적인 부분이 미흡하였고, 대유행 인플루엔자에 대한 기본적인 이해가 부족하였다. 훈련에 참여한 37명의 직원 중에서 훈련 후 시행한 설문에 21명(57%)이 응답하였다. 훈련 후 평가에서 탁상훈련의 전반적인 만족도에 대한 질문에서 81%가 만족하였다고 답변을 하였고, 새로운 것을 배우는데 유용했는가 대한 질문에도 86%가 유용했다고 답변하였다. 결론 : 탁상훈련은 의료기관의 대유행인플루엔자 대비에 효과적인 훈련방법이라고 생각되며 훈련을 통해 의료기관 내의 여러 부서들이 각 의료기관의 특성에 맞는 현실적이고 실제적인 대비 계획을 수립하는데 도움을 줄 것으로 기대된다. 그러나 향후 토른 촉진, 구체적인 결과에 도달을 유도할 수 있는 질문, 끼워넣기 개발, 적절한 시간 등에 대한 연구가 필요할 것으로 생각된다. Background : To evaluate the usefulness and compliance of a hospital-based tabletop exercise in setting of pandemic influenza in hospitals. Materials and Methods : Tabletop exercise was held in Pusan National University Hospital and forty two hospital employees were invited to participate in the exercise. The scenario for hospital-based tabletop exercise was designed. It consisted of three modules, which simulated the influx and outbreak of H5N1 influenza that was epidemic in Southeast Asia. Pre-, post-exercise surveys were completed by anonymous questions. Results : Thirty-seven (88%) of 42 invited participants attended exercise. AII members of the administration group and the ancillary services group participated. But, only 77% members of the clinical services group participated. In pre-exercise survey, priorities of eight goals regarding skills and knowledge during exercise were inquired., The highest priorities pointed out by the respondents were "Increase the knowledge of pandemic influenza" (22%), "Development of strategies for optimal communication among employees within specific department" (19%) and "Development of strategies for improved coordination between facilities within the health system" (19%). Twenty-one (57%) of participants completed the post-exercise surveys. At post-exercise surveys, 81% of the participants stated that the tabletop exercise was extremely or very useful, 86% of the participants also stated that it increased their knowledge of pandemic influenza. Conclusion : Tabletop exercise is an effective modality for increasing pandemic influenza preparedness in hospitals, and this method is useful for guiding preparedness activities within the hospital environment. Further studies to determine the appropriate method of discussion, questionnaire, duration of exercise and injection are needed.

      • KCI등재

        임플란트의 collar design이 변연골과 연조직에 미치는 영향

        유현상,강선녀,정창모,윤미정,허중보,전영찬 대한치과보철학회 2012 대한치과보철학회지 Vol.50 No.1

        연구 목적: 임플란트 경부가 잘 설계된 경우 양호한 연조직 반응을 통해 변연골을 보존하는데 도움이 된다. 본 실험에서는 연, 경조직 경계부에 가장 가까이 위치하는 임플란트의 collar design이 변연골 변화와 연조직 반응에 미치는 영향을 동물실험을 통해 알아보고자 하였다. 연구 재료 및 방법: 2마리의 건강한 Beagle dog에 임플란트 collar design만 다른 두 종류의 임플란트(Neobiotech Co. Seoul, Korea)를 식립하였다. Collar에 bevel 을 부여한 군(Bevel 군)과 "S"자 형태를 부여한 군(Bioseal 군)으로 나누어 마리 당 7개, 군당 7개, 총 14개의 임플란트를 무작위로 식립한 후 Healing abutment를 즉시 체결하였다. 디지털 표준구내 방사선사진을 이용해 4주 간격으로 총 12주간 근원심 변연골 변화를 관찰하였고, 12주에 희생하여 조직학적 분석을 통해 협설 변연골 흡수 및 임플란트 주변 연조직 반응을 평가하였다. Mann-Whitney test를 통해 동일한 방사선 사진 촬영 시점에서 근원심 변연골 변화량 및 조직계측치를 군 간 비교하였고, Kruskal-Wallis test를 통해 방사선 사진상 근원심 변연골 변화량이 시간에 따른 차이가 있는지 군 내 분석 한 후 Duncan test를 통해 사후 검증하였다(α=.05). 결과: 방사선학적 분석 결과 각 촬영 시점에서 두 군간 근원심 변연골 변화량의 차이를 보이지 않았다(P>.05). 군 내에서 시간에 따른 근원심 변연골의 흡수량을 분석한 결과 Bevel 군에서는 시간에 따른 차이를 보이지 않았으나 (P>.05), Bioseal 군에서는 시간에 따른 차이를 보였으며, 4주및8주와 비교했을 때 12주에서 변연골의 증가를 보였다(P<.05). 조직학적 분석 결과 협설측 변연골 흡수량에서 두 군간 차이를 보이지 않았으나 (P>.05), Bevel 군에 비해 Bioseal 군에서 더 견고한 결합조직부착을 관찰할 수 있었으며, 생물학적 폭경의 값은 두 집단 간 차이를 보이지 않은 반면에 (P>.05), 접합상피부착은 Bevel 군에서 유의하게 길었고, 결합조직부착은 Bioseal 군에서 더 길게 나타났다(P<.05). 결론: Bevel 군에 비해 Bioseal 군에서 결합조직부착은 길게 형성된 반면에 접합상피부착은 더 짧게 나타났으며, 생물학적 폭경과 초기 변연골 흡수에는 차이가 없음을 알 수 있었다. 연조직 반응의 차이가 실제 기능하중 하에서 변연골 변화에 미치는 영향에 대해서 향후 연구가 필요할 것으로 생각된다. PURPOSE. The purpose of this study was to investigate the effects of implant collar design on marginal bone change and soft tissue response by an animal test. MATERIALS AND METHODS. Two types of Implant (Neobiotech Co. Seoul, Korea) that only differs in collar design were planted on two healthy Beagle dogs. The implants were divided into two groups, the first group with a beveled collar (Bevel Group) and the second group with "S" shaped collar (Bioseal group). Standardized intraoral radiographs were used to investigate the mesio-distal change of the marginal bone. Histological analysis was done to evaluate the bucco-lingual marginal bone resorption and the soft tissue response adjacent to the implant. Mann-Whitney test was done to compare the mesio-distal marginal bone change at equivalent time for taking the radiographs and the tissue measurements between the groups. RESULTS. Radiographic and histological analysis showed that there was no difference in marginal bone change between the two groups (P>.05). Histological analysis showed Bioseal group had more rigid connective tissue attachment than the Bevel group. There was no difference in biological width (P>.05). Bevel group showed significantly longer junctional epithelium attachment and Bioseal group showed longer connective tissue attachment (P<.05). CONCLUSION. For three months there were no differences in marginal bone change between the Bevel group and the Bioseal group. As for the soft tissue adjacent to the implant, Bioseal group showed longer connective tissue attachment while showing shorter junctional epithelium attachment. There were no differences in biologic width.

      • KCI등재

        금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구

        조재영,강선녀,정창모,윤미정,허중보,전영찬 대한치과보철학회 2012 대한치과보철학회지 Vol.50 No.1

        연구 목적: 임플란트-골 계면에서 발생하는 과도한 열은 골유착을 저해하여 임플란트의 실패를 유발한다. 이에 이번 연구에서는 임플란트 금 합금 보철물의 교합면 삭제시 임플란트-골 계면으로의 열전달 양상과 냉각 방식의 효율성을 알아 보고자 하였다. 연구 재료 및 방법: 온도 감지 장치 제작을 위하여 Internal cone 연결형태의 임플란트에 16개의K형 열전대를 부착하여 아크릴릭 레진에 포매하였다. 치과용 금 합금과 주조용 abutment를 사용하여 교합면에 3개의 요철을 가지는 시편을 10개 제작하였고, 연결 나사를 이용하여 임플란트와 연결한 뒤 온도 감지 장치를 37℃로 유지되는 수조에 위치시켰다. 저속 핸드피스와 green stone bur를 이용하여 30초 동안 보철물의 요철을 삭제하였는데, 무냉각군, 공기 냉각 군, 물 분사 냉각 군으로 나누어 요철을 삭제하였다. 보철물이 삭제 되는 동안 임플란트의 부위별로 온도가 0.05초 간격으로 기록되었고, 삭제를 멈춘 뒤에도 무 냉각 군의 경우 임계 온도인 47℃ 이하로 온도가 하강할 때까지, 공기 냉각군과 물 분사 냉각군의 경우 삭제 중단 후 30초 동안 추가로 온도를 기록하였다. 냉각 방식에 따른 임플란트-골 계면의 온도를 알아보고, 임플란트의 부위별 온도변화의 유의차를 알아보기 위하여 one-way ANOVA를 실시하였고, Turkey HSD 이용하여 95% 유의수준에서 사후 검증하였다. 결과: 무 냉각 군은 임플란트-골 계면의 온도가 47℃ 이상으로 상승하였으며, 임플란트의 경부에서 유의하게 높은 열이 측정되었다(P>.05). 공기냉각군과 물분사 냉각군은 임플란트-골 계면의 온도가 47℃ 이하로 유지되었다. 무 냉각 군에서 임플란트 경부의 온도가 47℃에 도달되는 데는 약 10.8 ± 1.5초가 소요되었다. 공기 냉각 군과 물 분사 냉각 군 사이에서는 임플란트-골 계면 온도의 유의차가 없었다(P>.05) 결론: 이상의 결과로부터 임플란트 금 합금 보철물의 교합면 삭제 시, 임플란트 주위 조직에 위해를 가할 수 있는 임계 온도 이상의 열이 발생했음을 알 수 있었으며, 냉각방식은 공기 냉각과 물 분사 냉각 모두 효과적이라고 생각된다. PURPOSE. The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. MATERIALS AND METHODS. The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the 37℃ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. RESULTS. The mean maximum temperature was measured more than 47℃ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). CONCLUSION. The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

      • KCI등재후보

        Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at 150℃, 200℃, 250℃ and 300℃ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed 130.82±2.96℃ 158.00±5.26℃, 215.93±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93±0.09℃ at 250℃ setting and 5.69±0.15℃ at 300℃ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital temperature display of System B HeatSource.

      • KCI등재후보

        적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석

        최성아,김선호,황윤찬,윤창,오병주,최보영,정우남,정선와,황인남,오원만 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.4

        This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The heat carrier system 'System B' (Model 1005. Analytic Technologies, USA) and the Buchanan's pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infraed thermography (Radiation Thermometer-IR temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it(p<0.001). 2. When the pluggers were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3±10.5℃ to 192.1±3.3℃ in a touch for 1 sec, from 218.6±5.0℃ to 179.5±4.2℃ in a touch for 2 sec, from 197.5±3.0℃ to 167.6±3.7℃ in a touch for 3 sec, from 183.7±2.5℃ to 159.8±3.6℃ in a touch for 4 sec and from 164.9±2.0℃ to 158.4±1.8℃ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temerature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature dose not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommended, and finally a quick touch of heat control spring for 1 sec reveals the highest temperature rise.

      • KCI등재후보

        열전대(thermocouple)를 이용한 Buchanan Plugger 표면의 온도상승 분석

        조진숙,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was performed to evaluate the actual temperature rise on the surface of Buchanan plugger using thermocouple. The heat carrier system 'System B Heatsource'(Model 1005, Analytic Technologies, Redmond, WA, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ on digital display and the power level on it was set to 10. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 mm increments from the tip to the 4 mm length of shank. The heat control spring was touched for 5 seconds, and temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01 using Data Logger. The data were statistically analyzed by one-way ANOVA. The results were as follows. 1. The position at which the temperature peaked was approximately at 1~2 mm far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25±2.28℃ in F plugger, 185.94±2.19℃ in FM plugger, 169.51±9.12℃ in M plugger, and 160.79±1.27℃ in ML plugger and the peak temperature was highest in F plugger and followed by, in descending order, FM plugger, M plugger. ML plugger showed the lowest peak temperature (p<0.01). 3. The temperature on the pluggers was decreased with the increase of touching time. This results suggest that the actual temperature on the surface of the pluggers dose not correlate well with the temperature set on digital display. Heat concentrates around the up. The larger plugger reveals lower temperature rise relatively.

      • KCI등재

        유색미에 관한 연구 : Ⅲ. 유색미 유망계통에 대한 주요 생육 특성

        김광수,최윤표,김선택,최현구,정종태,김보경,유지홍,이희봉 충남대학교 농업과학연구소 2007 농업과학연구 Vol.34 No.2

        국내외 유색미 수집종을 돌연변이원에 의해 유기된 우수 계통과 수집종간 상호교배에 의해 선발된 CNU 20계통을 파종하여 얻어진 주요 작물학적 특성을 살펴보면 다음과 같다. 1. 간장은 유색 메벼인 CNU126 계통이 대조품종인 동진벼와 같이 가장 컸고 메성인 CNU 128계통에서 가장 작았다. 2. 주당 분얼수는 CNU3, CNU50. CNU56, CNU112 계통에서 가장 많았고 대조품종과 CNU 128 계통에서 10개 미만으로 가장 적게 나타났다. 3. 수장은 육성 계통 중 CNU88 계통에서 가장 길었으나 대조구보다 짧고, 육성계통 중에서는 CNU 126 계통이 가장 짧았다. 4. 주당 영화수는 대조구인 동진벼보다 CNU50 계통에서 2배 이상 많았고, CNU158 계통에서 가장 적게 나타났다. 5. 천립중은 CNU113 계통에서 30g이상으로 대조구와 같이 가장 무거웠고, CNU128 계통에서 20g으로 가장 적었다. 6. 주당 수량은 대조구의 26.6g에 비해 CNU50, CNU112 계통에서 두배정도 높았고, CNU128, CNU158, CNU200 계통에서 가장 낮게 타나났다. Aims of this study were carried out to develop the useful lines induced from mutation and pedigree breeding methods among the collected genetic resources from national and domestic areas. In this study, Stem height of CNU126 line and check among them were high, while CNU128 was lower than other lines. Spiklet length of CNU88 was longer, but that of CNU126 was shorter than check. Number of spiklets per plant of CNU50 among lines have twice time than check. 1,000 grains weight of CNU113 was higher than check. In yield per plant, CNU50 and CNU112 were higher than check, Dongjinbyeo.

      • Thermocouple을 이용한 Buchanan Plugger 표면의 온도상승 분석

        조진숙,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was performed to confirm the actual temperature rise on the surface of Buchanan plugger by evaluating the temperature rise on the surface of it, the peak temperature of pluggers of various size using thermocouple. The heat carrier system 'System B Heatsource' (Model 1005, Analytic Technologies, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200 which Dr. Buchanan's "Continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. The touch mode was used. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 ㎜ increments from the tip to the 4 ㎜ length of shank. Each thermocouple was secured with cyanoacrylate adhesive and orthodontic resin block. The two wire leads of each thermocouple were connected to the appropriate channels of Data Logger. This was configured to simultaneously record input from the five thermocouples. The heat control spring was touched for 1, 2, 3, 4 and 5 seconds, and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01. Ten trials was determined for each plugger. The average of temperature rise and standard deviation was calculated for each size of plugger. The data were statistically analyzed by one-way ANOVA to determine their significance. The results as follows. 1. The position at which the temperature peaked was approximately at 1∼2㎜ far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25±2.28℃ in F plugger, 185.94±2.19℃ in FM plugger, 169.51±9.12℃ in M plugger, and 160.79±1.27℃ in ML plugger and the peak temperature was highest in F type and followed by, in descending order, FM type, M type. ML type showed the lowest peak temperature (p<0.01). This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.

      • Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was conducted to evaluate safety to the supporting tissues of the root while the root canal is obturated using continuous wave of condensation technique. A extracted maxillary central incisor was prepared for repeated canal obturation. After conventional access opening, working length was then established to the point 1㎜ from anatomical root apex. The root canal was prepared with GT rotary Ni-Ti file (Dentsply Maillefer, Switzerland). Five thermocouples (Onega Engineering Inc., USA) were placed at 2㎜ increments on one side beginning 1㎜ from the anatomical root apex and the other five thermocouples at 2㎜ increments on the other side beginning 2㎜ from it. For obturation, a nonstandardized medium size gutta-percha cone and a ML Buchanan plugger (Analytic technologies, USA) were selected. After drying of root canal, AH 26 root canal sealer (Dentsply Detrey, Germany) was applied on the wall of the root canal. Baseline temperature was measured on the root surface. The ML size plugger was preheated for 2seconds and then the real temperature of it was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan. The root surface temperature was recorded during obturation and it was performed ten times at each of the following temperature settings: 150℃, 200℃, 250℃ and 300℃. After completion of the temperature recording, the dentinal-cementum thickness at each sites where thermocouples were attached was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1㎜ point from the tip revealed 130.82±2.96℃, 158.00±5.26℃, 215.92±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 ㎜ from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93± 0.09℃ at 250℃ setting and 5.69± 0.15℃ at 300℃ setting. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital display of System B HeatSource.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼