RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 紅花 Extract가 家兎 血淸脂質 및 脂蛋白分劃에 미치는 影響

        양남길,고광삼,차종희 朝鮮大學校 醫學硏究所 1979 The Medical Journal of Chosun University Vol.- No.-

        In this study, the influence of carthami flos extract (CFE) on the serum levels of total cholesterol, triglyceride, phosphohpid and lipoprotein fraction patterns in rabbits. Carchami flos was extracted by water. and the extract was orally administeied to rabb- its that was starvated for three days. The results were as follows ; 1. By administration of CFE, the strum levels of total cholesterol and triglvceride were gradually decreased and were returned to about the control levels after 15 days. 2. The serum phospholipid level was slightly increased to the control level by adminis-tration of CFE. 3 The serum α-lipoprotein fraction was decreased, pre-β-lipoprotein fraction was incr-eased and β-lipoprotein fraction was gradually decreased after 15-days by administration of CFE. 4. After three days starvation, the serum levels of total cholesterol. triglyceride were markedly increased, while phospholiped level was slightly decreased in rabbits.

      • KCI등재

        간접변환방식 DR장비에서 CsI:Tl과 Gd<sub>2</sub>O<sub>2</sub>S의 검출기 화질 평가

        공창기 ( Changgi Kong ),최남길 ( Namgil Choi ),정묘영 ( Myoyoung Jung ),송종남 ( Jongnam Song ),김욱 ( Wook Kim ),한재복 ( Jaebok Han ) 한국방사선학회 2017 한국방사선학회 논문지 Vol.11 No.1

        본 연구의 목적은 DR (digital radiography) 장비에서 팬텀을 이용하여 간접변환방식의 CsI:Tl 검출기와 Gd2O2S 검출기를 중심으로 두께가 두꺼운 흉부 팬텀과 중간 두께의 대퇴부 팬텀, 그리고 피사체의 두께가 얇은 손 팬텀의 영상을 획득하고 SNR과 CNR을 분석하여 검출기의 특성을 알아보고자 하였다. 피사체 두께 변화에 따른 SNR과 CNR을 측정한 결과 중간 두께의 대퇴부 팬텀과 두께가 얇은 손 팬텀을 촬영 하였을 때 SNR과 CNR은 Gd<sub>2</sub>O<sub>2</sub>S 검출기보다 CsI:Tl 검출기에서 높게 나타났음을 확인 할 수 있었다. 그러나 두께가 두꺼운 흉부 팬텀을 사용하였을 때는 Gd<sub>2</sub>O<sub>2</sub>S 검출기의 SNR이 80∼125 kVp 일 때와 CNR이 0∼110 kVp 일 때 CsI:Tl 검출기 보다 값이 높게 나타났고, 저관전압에서 고관전압으로 갈수록 SNR과 CNR은 모두 증가하였다. 중간 두께의 대퇴부 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 40∼50 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었고, Gd<sub>2</sub>O<sub>2</sub>S 검출기의 SNR과 CNR은 40∼60 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었다. 두께가 얇은 손 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 저관전압에서 감소하다가 고관전압으로 갈수록 증가하면서 100∼110 kVp에서는 소하였고, Gd<sub>2</sub>O<sub>2</sub>S 검출기의 SNR과 CNR은 고관전압으로 갈수록 감소하는 것을 확인하였다. MTF는 0.5 ∼3 lp/mm에서 CsI:Tl 검출기가 Gd<sub>2</sub>O<sub>2</sub>S 검출기보다 6.02∼90.90%로 높음 보여주고 있고, DQE는 0.5∼3 lp/mm에서 CsI:Tl 검출기가 Gd<sub>2</sub>O<sub>2</sub>S 검출기보다 66.67∼233.33% 높음 보여주고 있다. 결론적으로 MTF와 DQE의 비교에서는 CsI:Tl 검출기가 Gd<sub>2</sub>O<sub>2</sub>S 검출기보다 높게 나타났지만, 두꺼운 흉부팬텀에서 일정 관전압 구간에서는 저가의 Gd<sub>2</sub>O<sub>2</sub>S 검출기가 고가의 CsI:Tl 검출기보다 SNR과 CNR이 높다는 것을 확인하였다. 흉부 X선 검사 시 CsI:Tl 검출기보다 Gd<sub>2</sub>O<sub>2</sub>S 검출기를 사용하여 우수한 화질의 흉부 영상을 구현함으로써 검사에 유용할 것으로 판단되어지며, 사용자 입장에서 검출기 형태를 결정 할 때 가격 대비 성능을 고려 해볼 사항으로 판단된다. The purpose of this study was to investigate the features of CsI:Tl and Gd<sub>2</sub>O<sub>2</sub>S detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in Gd<sub>2</sub>O<sub>2</sub>S detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80∼125 kVp and the CNR at 80~110 kVp in the Gd<sub>2</sub>O<sub>2</sub>S detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40∼50 kVp and decreased as the tube voltage increased. The SNR and CNR of Gd<sub>2</sub>O<sub>2</sub>S detector increased at 40∼60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100∼110 kVp, while the SNR and CNR of Gd<sub>2</sub>O<sub>2</sub>S detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02∼90.90% higher than that of Gd<sub>2</sub>O<sub>2</sub>S detector at 0.5∼3 lp/mm. The DQE of CsI:Tl detector was 66.67∼233.33% higher than that of Gd<sub>2</sub>O<sub>2</sub>S detector. In conclusion, although the values of CsI:Tl detector were higher than those of Gd<sub>2</sub>O<sub>2</sub>S detector in the comparison of MTF and DQE, the cheaper Gd<sub>2</sub>O<sub>2</sub>S detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the Gd<sub>2</sub>O<sub>2</sub>S detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

      • KCI등재후보

        체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교

        차상영(Sangyoung Cha),신재한(Jaehan Shin),최남길(Namgil Choi) 한국방사선학회 2016 한국방사선학회 논문지 Vol.10 No.8

        체중부하 상태에서의 족관절 검사 시 양측 족관절을 동시 촬영 했을 때와 편측 족관절을 나누어 각각 촬 영 했을 때, 족관절염의 평가에 해당되는 측정값들의 변화에 대해 알아보고자 한다. 양측을 동시촬영 할 때, 다리를 모아 촬영하게 됨으로 Tibia axis축이 기울게 되고, 족관절의 external rotation으로 인해 족관절의 각도와 joint space의 왜곡이 발생하게 된다. 양측 족관절 동시촬영과 편측 족관절을 나누어 촬영한 영상을 PACS system 이용하여 족관절 평가에 이용되는 TAS, TT, TMM, JSW, Tibiotalar joint, Fibulotalar joint의 측 정값을 구한 후 통계 분석 하였다. 각도 측정에 있어, 체중부하 양측 족관절 동시 촬영한 검사의 오른쪽 족 관절의 TAS, TT, TMM 측정값은 87.24°, 6.44°, 26.67° 이였으며 편측을 나누어 촬영한 오른쪽 족관절의 TA S, TT, TMM은 88.93°, 2.41°, 19.77° 였다. 양측 족관절 동시촬영의 왼쪽 족관절 TAS, TT, TMM의 측정값은 87.25°, 5.71°, 23.92° 였으며 편측을 나누어 촬영한 왼쪽 족관절의 TAS, TT, TMM은 88.75°, 3.19°, 21.45° 였 다. 양측 족관절을 동시촬영한 검사와 편측을 나누어 촬영한 족관절과의 비교 시, 양측을 동시 촬영한 검사 에서 족관절 평가의 중증도 비율이 높게 나타났으며, 자세로 인한 측정값의 왜곡을 확인할 수 있었다. 반면 너비 측정에서 JSW, Tibiotalar joint는 검사 자세로 인한 측정값들 간의 유의성은 없었지만, Fibulotalar joint 의 양측 족관절 동시 검사에서 오른쪽 0.98mm 왼쪽 1.22mm 로 나타났고, 한쪽씩 촬영한 오른쪽 족관절에 서는 1.6mm 왼쪽 1.22mm로 측정 자세로 인한 측정값의 유의한 차이를 보였다. 따라서 족관절염 평가를 위 한 체중부하 족관절 검사시 양측을 동시에 검사하기 보다는 각각의 족관절을 나누어 촬영하는 것이 족관 절염 평가값에 왜곡을 최소화 하며, 측정값의 정확성을 높일 수 있다. This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was 87.24°, TT was 6.44°, TMM was 26.76°, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was 88.93°, TT was 2.41°, TMM was 19.77°, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was 87.25°, TT was 5.71°, TMM was 23.92°, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was 3.19°, TMM 21.45°, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.

      • KCI등재

        개인정보 유출 사고 시 정보보호 기업의 주가 변동에 관한 연구

        김민정(Min-Jeong Kim),허남길(Namgil Heo),유진호(Jinho Yoo) 한국정보보호학회 2016 정보보호학회논문지 Vol.26 No.1

        현재 우리나라의 인터넷과 IT 인프라는 세계 최고 수준을 유지하고 있다. 그러나 그 이면에는 보안사고, 특히 개인정보 유출 사고가 빈번히 발생하고 있다. 개인정보 유출 사고 발생 시 해당 기업은 부정적 영향을 받게 되며, 이를 방지하기 위해 정보보호 업체의 다양한 보안 솔루션을 사용하고 있다. 따라서 개인정보 유출 사고 발생 시 발생기업은 물론 기업에 보안 솔루션을 제공하는 정보보호 업체에도 영향을 미칠 것으로 생각된다. 이에 본 논문에서는 개인정보 유출 사고 발생 시 정보보호 업체의 주가 변화를 통해 보안 이벤트가 정보보호 업체의 가치에 어떠한 영향을 주는지 가설을 세워 검증하였다. 그 결과 개인정보 유출 사고 발생 시 정보보호 업체의 주가는 상승하였으며, 사고 규모, 사고 발생 업종에 따른 차이는 통계적으로 유의하지 않았고, 정보보호 업체의 업태 구분에 따른 차이가 존재하였다. Currently Internet and IT infrastructure of Korea has maintained the world’s highest levels. But in another aspect, security incident, especially personal information breaches occur frequently. As personal information leakage happened, the companies will be negatively affected. And to prevent this, they have implemented to use a variety of security solutions from information security vendors. Therefore we set up hypotheses that the companies experienced personal information leakage as well as information security companies providing security solutions will be affected by the leakages. So this paper verify hypotheses about the impact of the value of information security companies, through analysing stock price fluctuation of the companies. We found that the stock price of information security companies has increased as personal information leakage happened. And differences according to leakage volumes and types of business are not statistically significant. But there are significant differences according to business classification of information security companies.

      • 총의치 환자의 심미회복

        김성진,강남길,Kim, Sungjin,Kang, Namgil 대한심미치과학회 2017 Journal of the Korean Academy of Esthetic Dentistr Vol.26 No.1

        임기존 hader bar의 재위치 문제를 해결하고 무치악 환자에서 부적합한 악간관계 채득으로 인한 비심미적인 안모와 부적절한 교합문제를 해결하기 위해서 치아 상실 전의 자연치의 위치와 비슷한 위치로 교합고경 설정과 치아 배열을 수행했다. 부적합한 환자의 안모를 회복하여 심미적인 개선을 이루었고, 더불어 의치의 이차적인 심미에 대한 만족감을 최대한으로 높이기 위하여 컴포지트 레진을 사용하여 마무리하였다. In order to solve the problem of repositioning the old hader bar attachment and to restore the non-esthetic facial profile and improper occlusion of the edentulous patient due to inadequate jaw relation, determination of vertical dimension of occlusion and tooth arrangement were performed similar to the natural teeth before the teeth loss. In addition to improving the esthetics by restoring the inadequate facial appearance, the composite resin was used to maximize the patient's secondary esthetic satisfaction with the denture.

      • Effect of GaN Microlens Array on Efficiency of GaN-Based Blue-Light-Emitting Diodes

        Kim, Dongwoo,Lee, Hyoyoung,Cho, Namgil,Sung, Younjoon,Yeom, Geunyoung The Japan Society of Applied Physics 2005 Japanese journal of applied physics Vol.44 No.1

        <P>In this study, GaN-based vertical light-emitting diodes (VLEDs) were fabricated by a laser lift-off (LLO) process and the effects of microlens formation by plasma etching on the optical properties of the LLO GaN-based VLED devices were investigated. By forming a 5–10 μm microlens array on the LLO GaN-based VLEDs, the measured light emission intensities at 460 nm and in the direction normal to the surface of the device increased by approximately 40% and 100% compared with those of the LLO GaN-based VLED without the microlens array for 10 μm and 5 μm microlens arrays, respectively.</P>

      • KCI등재

        Focus DWI 검사에서 중심축 이동에 따른 화질 평가

        김용화(Younghwa Kim),정문택(Moontaeg Jeong),최남길(Namgil Choi) 한국방사선학회 2018 한국방사선학회 논문지 Vol.12 No.5

        기존의 자기공명영상검사에서 문제점으로 지적되어 왔던 위상부호화 방향에서의 긴 판독시간과 낮은 대역폭과 함께 기하학적 왜곡의 경향이 있어 이러한 영상왜곡을 감소하기 위한 여러 방법 중 FOCUS-DWI가 있다. 본 논문은 선택적인 위상 방향 및 슬라이스를 이용하는 FOCUS-DWI가 자기장 내 중심축에서 거리 변화에 따른 인공물, 균일도를 기존의 Conventional-DWI와 비교하여 그에 대한 유용성을 확인하고자 하였 다. 인공물 발생에 대한 결과는 Conventional-DWI 기법에서 불규칙적인 줄무늬 인공물이 발생하였는데 중심축에서 인공물의 발생이 심하게 나타났고, 영상의 겹침 정도가 급격하게 증가하였다. 하지만 FOCUS-DW I 기법은 줄무늬 모양의 인공물 발생이 나타나지 않았고 영상의 겹침 정도도 적게 나타났으며, 영역별 신호 측정에 대한 균일도 결과는 중심축에서 거리의 변화에 관계없이 FOCUS-DWI가 훨씬 우수한 기법으로 나타났다. 결론적으로 FOCUS-DWI 기법은 인공물, 영상의 겹침 정도, 균일도 측정에서 Conventional-DWI 기법보다 우수한 결과를 보였고, 거리의 변화에 따른 두 기법에서는 차이가 없게 나타났다. 따라서 FOCUS-DWI 기법은 영상의 왜곡 정도가 적고 화질이 우수하여 임상에서 활용도가 높을 것이라 사료된다 The problem that the existing the magnetic resonance image (MRI) was prone to have not only long readout duration and low bandwidth in the phase-encode direction, but also geometric distortion was pointed out. The purpose of this study is to identify the usefulness of FOCUS-DWI through comparing FOCUS-DWI with the Conventional-DWI on a degree of uniformity and artifacts caused by the distance change in the central axis within the magnetic field. In terms of artifacts, there happened irregular striped artifacts in the Conventional-DWI technique, which in particular, more often arose in the central axis. Also, the overlap of imaging drastically increased. By contrast, there were no irregular striped artifacts in the FOCUS-DWI technique. In conclusion, it was found that the FOCUS-DWI technique was superior to the Conventional-DWI technique in terms of artifacts, the overlap of imaging, and a degree of uniformity. In addition, there was no difference of the change in distance from the central axis between the FOCUS-DWI technique and the Conventional-DWI technique. Thus, it is considered the FOCUS-DWI technique having less imaging distortion and high image quality will be highly clinically used.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼