RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 남성화를 보이는 여성에서 발견된 난소의 Steroid Cell Tumor 1예

        조인호,정대훈,박영미,서영진,손영실,정철회,강영미,정수전,김영남,이경복,성문수,김기태 인제대학교 2006 仁濟醫學 Vol.27 No.-

        Steroid cell tumor is a rare ovarian sex cord-stromal tumor which accounts for 0.1% of all ovarian tumors. Until now, only 4 cases have been reported in domestic literatures. Steroid cell tumor often secrets testosterone and presents virilization in adult women or precocious puberty in children. Treatment is often performed by surgical removal, adjuvant chemotherapy and radiation, but completely accepted treatment was not existed. We experienced a case of steroid cell tumor, which was manifested by typical virilization in a 43-year old patient, who was previously performed hysterectomy and unilateral oophorectomy. So, we present with a brief review of the literatures.

      • 헬륨 마이크로파 플라즈마 토치의 개발과 특성에 관한 연구

        曺競鉉,朴勇男 한국교원대학교 환경과학연구소 2002 환경연구논문집 Vol.- No.7

        MPT는 최근에 개발된 마이크로파 플라즈마로서 수용매에 강하다. 여러 가지의 변형된 형태의 MPT를 개발하여 구조에 따른 플라즈마의 방전되는 형태를 조사한 결과 이중관 토치는 플라즈마 기체를 적게 소모하며 쉽게 플라즈마가 형성되었으나 토치의 끝이 높은 온도에 견디지 못하고 쉽게 상했다. ICP토치와 같은 형태의 삼중관 토치에 석영관을 중심관으로 사용할 때 가장 안정되고 대칭적인 플라즈마를 형성할 수 있었다. 바탕선을 조사해 본 결과 He MPT는 대기 중으로 돌출되어 대기와 많이 혼합되고 질소에 의해 quenching되는 것으로 보여진다. Membrane desolvator를 탈용매화 장치로 사용하여 헬륨 MPT의 감도를 조사해 본 결과 아르곤 MPT와 비교할 때 대부분의 원소에 대해 검출한계가 10배 이상 높았다. 그러나 여기 에너지가 높은 원소는 비교적 효율적으로 검출할 수 있었다. 헬륨 마이크로파 플라즈마는 적은 양의 플라즈마 기체만 필요하여(약 1.6L/min)경제적이며 매우 안정된 형태를 보여주었다. 플라즈마의 분광특성을 조사한 결과 들뜸온도 4950K, 전자밀도 3.28×10^14㎝^-3로 측정되었다. MPT, which has been developed recently, is very tolerant to aqueous samples. Several types of MPT have been investigated and is found that the double concentric tube could sustain a stable plasma at a low plasma gas flow rate. However, the tip of torch is easily ruined. Triple concentric torch has shown the best stability and the plasma shape, much like that of ICP, especially when the central channel is quartz. The plasma is exposed and mixed with air is suggested from the background spectrum, which leads to quenching of He MPT. Sensitivity of helium MPT equipped with a membrane desolvator has shown 10 times lower than that of Argon MPT for most of elements except for the ones with relatively high excitation energy. He MPT requires small plasma flow rate(about 1.6L/min), stable and simple to use. Excitational temperature and electron number density measured are 4950 K and 3.28×10^14㎝^-3, respectively.

      • 헬륨 마이크로파 플라즈마 토치의 개발과 특성에 관한 연구

        曺競鉉,朴勇男 한국교원대학교 환경과학연구소 2001 환경연구논문집 Vol.- No.6

        MPT는 최근에 개발된 마이크로파 플라즈마로서 수용매에 강하다. 여러 가지의 변형된 형태의 MPT를 개발하여 구조에 따른 플라즈마의 방전되는 형태를 조사한 결과 이중관 토치는 플라즈마 기체를 적게 소모하여 쉽게 플라즈마가 형성되었으나 토치의 끝이 높은 온도에 견디지 못하고 쉽게 상했다. ICP토치와 같은 형태의 삼중관 토치에 석영관을 중심관으로 사용할 때 가장 안정되고 대칭적인 플라즈마를 형성할 수 있었다. 바탕선을 조사해 본 결과 He MPT는 대기 중으로 돌출되어 대기와 많이 혼합되고 질소에 의해 quenching되는 것으로 보여진다. Membrane desolvator를 탈용매화 장치로 사용하여 헬륨 MPT의 감도를 조사해 본 결과 아르곤 MPT와 비교할 때 대부분의 원소에 대헤 검출한계가 10배 이상 높았다. 그러나 여기 에너지가 높은 원소는 비교적 효율적으로 검출할 수 있었다. 헬륨 마이크로파 플라즈마는 적은 양의 플라즈마 기체만 필요하여(약 1.6L/min) 경제적이며 매우 안정된 형태를 보여주었다. 플라즈마의 분광특성을 조사한 결과 들뜸온도 4950 K, 전자 밀도 3.28×10^(14) cm^(-3)로 측정되었다. MPT, which bas been developed recently, is very tolerant to aqueous samples. Several types of MPT have been investigated and is found that the double concentric tube could sustain a stable plasma at a low plasma gas flow rate. However, the tip of torch is easily ruined. Triple concentric torch has shown the best stability and the plasma shape, much like that of ICP, especially when the central channel is quartz. The plasma is exposed and mixed with air as is suggested from the background spectrum, which leads to quenching of He MPT. Sensitivity of helium MPT equipped with a membrane desolvator has shown 10 times lower than that of Argon MPT for most of elements except for the ones with relatively high excitation energy. He MPT requires small plasma flow rate (about 1.6 L/min), stable and simple to use. Excitational temperature and electron number density measured are 4950 K and 3.28 × 10^(14) cm^(-3), respectively.

      • 보신 관광에서 감염된 수입성 Sparganosis 1예 : Intake of Thailand Snake during Trip

        서환조,박명재,고경식,백영한,조유정,양현종,류경남,정형근,전정열 대한감염학회 1992 감염 Vol.24 No.1

        Human sparganosois was reported more than 100 cases in Korean population. However no case reported yet in Korea as a patient was infected by sparganum from other geographical area, such as Thailand. The case we are reported here is a 38 year-old Korean male who had been suffered from mass being a small, round and soft consistance in upper portion of his right thigh. The patients stated that he had an opportunity to eat living snake in Bangkok, Thailand during trip. As therapy praziquantel (75㎎/㎏/day) was given p.o. for 14 days, but in vain to cure. Following medical treatment, surgical exicision was performed to remove a alive, soft, whitish-milky, mobile and elongated sparganum. Serlogical test by micro-ELISA for sparganum-specific antibody revealed a high serum antibody level of absorbance 0.67 (positive criterion: absorbance 0.22).

      • KCI등재

        비선형 음향효과에 의한 고온 재료의 파괴인성 열화도 평가

        정현조,남승훈,장경영,남영현 한국비파괴검사학회 2000 한국비파괴검사학회지 Vol.20 No.5

        고온 장시간 사용재의 열화로 인한 파괴인성의 저하를 초음파 방법으로 평가하기 위하여 Cr-Mo-V 강을 실험실에서 인공 열화처리하여 열화로 인한 손상 기구를 규명하고, 열화도에 따른 초음파 파라미터의 변화를 체계적으로 관찰하였다. 초음파 파라미터로서 속도, 감쇠와 보다 최근에 개발된 비선형 음향 파라미터를 사용하였는데, 비선형 음향 파라미터가 가장 민감한 변화를 보였다. 또한 전기비저항 측정 결과와 비교할 때 두 방법 모두 전체적으로 유사한 거동을 보였다. Charpy V-notch 충격시험으로부터 구한 파면양상 천이온도(FATT)와 비선형 파라미터 사이에는 비교적 좋은 상관관계가 성립하였으며, FATT와 파괴인성(KIC) 사이의 관계식에 근거하여 열화된 발전설비 재료의 파괴인성을 초음파 비선형 파라미터의 측정을 통하여 간접적으로 구할 수 있음을 보였다. In order to develop an ultrasonic evaluation method for properties degradation of high temperature materials, a number of Cr-Mo-V steel samples were heat-treated, and their damage mechanism was examined. Ultrasonic parameters such as velocity, attenuation, and more recently developed nonlinear acoustic parameter were measured. The nonlinear acoustic parameter was found to be most sensitive to material degradation mainly attributed to the precipitation of impurities in grain boundaries. When compared to the electrical resistivity results, the nonlinear parameters showed similar behavior. There existed a relatively good correlation between the nonlinear parameter and the fracture appearance transition temperature (FATT) obtained by Charpy V-notch impact test. Based on the relationship between the FATT and the fracture toughness (KIC), correlation between the nonlinear parameter and KIC was established.

      • 란크릭 캅셀(플루옥세틴 20mg)에 대한 프로작 캅셀의 생물학적 동등성 시험

        심상범,조요나,오한석,류재환,이경태,김남재,서성훈 경희대학교 동서의학연구소 2001 東西醫學硏究所 論文集 Vol.2000 No.-

        Bioequivalence of two flouxetine capsule, ProzacR (Lilly kora Ltd.) and LanclicR (Samsung Pharm. IND. Co.), was evalated according to the guideline of KFDA. Twenty four healthy male volunteers (21-26 years old) were divided into two groups and a randomized 2×2 cross-over study was employed. After 60mg of fluoxetine was orally administered, blood was taken at 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 24, 32, 48 and 72 hours after administration and just before administration. Plasma was analyzed for fluoxetine and internal standard (clomipramine) by a sensitive and validated HPLC assay. The pharmaco kinetic parameters (AUCt, Cmax and Tmax) wre calculated and ANOVA test was used for the statistical analysis of parameters. Differences in (AUCt, Cmax and Tmax between two capsules were -0.90, 3.46 and -14.08% respectively. All powers (1-β) for AUGt, Cmax and Tmax were more than 0.9. Detectable differences (Δ) and confidence interval were all less than ±20%. All the parameters above met the criteria of KFDA for bioequivalence and indicated that LanclicR capsules are bioequivalent to ProzacR capsules.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼