RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        실리콘 웨이퍼 세정을 위한 오존의 거동에 관한 연구

        이건호,김인정,배소익,Lee Gun-Ho,Kim In-Jung,Bae So-Ik 한국반도체디스플레이기술학회 2005 반도체디스플레이기술학회지 Vol.4 No.4

        The behavior of ozone in $NH_4OH$ was investigated to evaluate the solution as a cleaning chemical of the silicon wafer. The solubility of ozone in DI(Deionized) water increased as the oxygen flow-rate decreased and ozone generator power increased. Ozone in DI water showed solubility of 100 ppm or higher at room temperature. Ozone concentration was stabilized at the range of ${\pm}2ppm$ by controlling oxygen flow rate and ozone generator power. On the contrary, the solubility of ozone in $NH_4OH$ was very low and strongly depended on the concentration of $NH_4OH$ and pH. The redox potential of ozone was saturated within 10 minutes in DI water and decreased rapidly with the addition of $NH_4OH$. The behavior of ozone in $NH_4OH$ is well explained by redox potential calculation.

      • KCI등재

        폐패각-정유폐촉매-배연탈황석고를 사용한 Calcium Sulfoaluminate 클링커의 합성과 특성

        이건호,송태웅,Lee, Keon-Ho,Song, Tae-Woong 한국세라믹학회 2005 한국세라믹학회지 Vol.42 No.7

        For the raw materials of 3CaO$\cdot$3Al$_{2}$O$_{3}$ $\cdot$CaSO$_{4}$(CSA) clinker manufacturing, the applications of industrial wastes such as waste shell, spent oil-refining catalyst and desulfurized gypsum were examined. The c1inkerbility of the raw mix and the behaviour of formation of clinker minerals were studied and then some hydraulic properties of cements containing the clinker were also investigated. By virtue of the high reactivity of thermally decomposed raw materials, CSA clinkers were obtained at relatively low temperature of 1250$^{\circ}C$ and thus oil-refining catalysts were more desirable than aluminium hydroxide as an aluminous raw material. The expansive cement samples showed somewhat lower flow value than that of OPC, but their compressive strengths were developed earlier and higher than that of OPC due to formation of ettringite in the early hydration time, which indicated the possibility of practical use of low-cost CSA clinker using industrial wastes only.

      • 유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰

        이건호,강효석,최병준,박상준,정다이,이두상,안민우,전명수,Lee, Geon Ho,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Du Sang,Ahn, Min Woo,Jeon, Myeong Soo 대한방사선치료학회 2019 대한방사선치료학회지 Vol.31 No.1

        목 적: 수술 후 유방암 환자의 1차 방사선치료 후 2차 방사선치료 시 단일전자선을 사용하는 것과 서로 다른 에너지의 전자선을 혼합하여 사용하는 방법에 대해 유용성을 평가하고자 한다. 대상 및 방법: 본 연구에서는 2018년 1월부터 10월까지 본원 유방암 방사선 치료 환자를 대상으로 하였으며, 혼합 전자선을 사용하여 2차 치료를 진행한 환자 59명 중 에너지 6 MeV, 9 MeV를 혼합 사용한 환자 40명(A그룹)과 9 MeV, 12 MeV를 혼합 사용한 환자 19명(B그룹)을 대상으로 진행하였다. 각 그룹의 환자마다 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV)와 9 MeV, 12 MeV, Combine(9 MeV / 12 MeV) 각기 다른 방법으로 세 가지 치료계획을 세우고, 원발병소에 전달되는 최대선량, D95, D5과 폐의 전달되는 최대선량, 평균선량, $V_3$, $V_5$, $V_{10}$을 비교 분석하였다. 결 과: A그룹 치료계획의 D95 평균값은 6 MeV에서 $785.33{\pm}225.37cGy$, 9 MeV에서 $1121.79{\pm}87.02cGy$, SUM(6 MeV / 9 MeV)에서 $1010.98{\pm}111.17cGy$였으며, 6 MeV / 9 MeV에서의 평균값이 처방 선량에 가장 적합했다. 치료하는 유방 방향의 폐의 저선량 영역 $V_3$,$V_5$의 평균값은 6 MeV / 9 MeV에서 $3.24{\pm}3.49%$, $0.72{\pm}1.55%$였고, 9 MeV에서 $7.25{\pm}4.59%$, $3.07{\pm}2.64%$로 가장 높은 값을 보였고, 6 MeV에서 $0.21{\pm}0.45%$, $0.03{\pm}0.07%$로 가장 낮은 값을 보였다. 폐의 최대선량과 평균선량은 6 MeV / 9 MeV에서 $727.78{\pm}137.27cGy$, $49.16{\pm}24.44cGy$였으며, 9 MeV에서 $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$로 가장 높았고, 6 MeV에서 $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$로 가장 낮았다. $V_{10}$의 값은 모두 0에 가까웠다. B그룹도 A그룹의 패턴으로 나타났다. 결 론: 폐의 $V_3$, $V_5$의 저선량 영역에서 상대적인 차이가 나타났으며, 혼합 에너지 적용 시 원발병소의 선량 전달에 있어서 가장 효과적임을 알 수 있었다. 유방암 추가 방사선 치료 시 전자선 에너지를 combine하여 사용하는 방법이 에너지 재원으로부터 제한되는 에너지의 효과를 좀 더 효과적으로 사용할 수 있는 방법이라고 사료되며 비록 작은 선량차이이기 때문에 간과하고 넘어갈 수 있는 부분들도 다시 한번 생각해본다면 조금 더 환자에게 도움이 되는 방사선 치료가 될 수 있을 것으로 사료된다. Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

      • KCI등재

        사례기반추론과 규칙기반추론을 이용한 e-쇼핑몰의 상품추천 시스템

        이건호,이동훈,Lee, Gun-Ho,Lee, Dong-Hun 한국정보처리학회 2004 정보처리학회논문지D Vol.11 No.5

        e쇼핑몰 경영자들은 고객들의 다양한 제품 구매 욕구를 충족시키기 위한 효율적 시스템에 많은 관심을 가지고 있다. 인터넷 쇼핑몰 운영에 있어 고객들의 개인적 구매 특성 및 취향을 파악하여 고객들을 효과적으로 관리하는데 많은 어려움이 있다. 상품 추천의 과정이 기획된 소수의 특정 상품을 고객의 유형 및 특성들의 고려 없이 공급자 중심으로 이루어져 고객관리의 문제점으로 지적되고 있다. 본 연구에서는 고객위주의 추천을 위해 규칙기반추론(Rule-Based Reasoning, RBR)과 사례기반추론(Case-Based Reasoning, CBR)을 하여 고객의 취향 및 구매 특성에 따른 추천방법을 제시한다. 기존의 제품 판매정보와 고객정보를 이용해 생성한 규칙베이스와 사례베이스의 고객특성과 입력된 고객특성의 유사도를 평가해서 고객의 취향에 따라 추천하도록 한다. 생성된 규칙과 사례기반의 추론으로 기존의 정보를 효과적으로 사용하고 또한 고객 및 시장 상황의 변화를 인식하고 지속적인 학습을 수행하여 지능적 추천이 이루어진다. It is a major concern of e-shopping mall managers to satisfy a variety of customer's desire by recommending a proper product to the perspective purchaser. Customer information like customer's fondness, age, gender, etc. in shopping has not been used effectively for the customers or the suppliers. Conventionally, e-shopping mall managers have recommended specific items of products to their customers without considering thoroughly in a customer point of view. This study introduces the ways of a choosing and recommending of products using case-based reasoning and rule-based reasoning for customer themselves or others. A similarity measure between one member's idiosyncrasy and the other members' is developed based on the rule base and the case base. The case base is improved for the system intelligence by recognizing and learning the changes of customer's desire and shopping trend.

      • KCI등재

        불화나트륨 바니쉬와 요오드화 칼륨이 Silver Diamine Fluoride의 재광화 효과에 미치는 영향

        이건호,안준용,김종수,한미란,이준행,신지선,Lee, Kunho,Ahn, Junyong,Kim, Jong Soo,Han, Miran,Lee, Joonhaeng,Shin Jisun 대한소아치과학회 2021 大韓小兒齒科學會誌 Vol.48 No.4

        이 연구의 목적은 silver diamine fluoride(SDF)를 도포할 때 불화나트륨(sodium fluoride, NaF) 바니쉬와 요오드화 칼륨(potassium iodide, KI)이 SDF의 재광화 효과에 미치는 영향을 유치의 법랑질 인공 우식 병소에서 미세경도의 변화를 통해 측정하고, 도포 전과 후의 표면 형태를 주사전자현미경(scanning electron microscopy, SEM)을 통해 관찰하여 비교하는 것이다. 발치된 유구치의 인접면에 법랑질 인공 우식병소를 형성하고 비커스 미세경도를 측정한 후, 4개의 군으로 나누어 I군에는 SDF, II군에는 SDF와 NaF 바니쉬, III군에는 SDF와 KI, 그리고 IV군에는 증류수를 처리하였다. 8일 간 pH cycling을 시행한 후 비커스 미세경도를 다시 한번 측정하여 미세경도의 변화량을 계산하였다. 또한 치아 연마 후, 인공 우식 유발 후, 그리고 pH cycling 이후 각 군에 대하여 각각 2개의 시편을 이용하여 SEM를 촬영하여 표면의 형태를 관찰하였다. 연구결과 미세경도는 III군에서 가장 크게 증가했다. I군과 II군 모두 미세경도의 증가를 보였으나 두 군 사이에는 통계학적으로 유의한 차이가 없었다. IV군에서도 미세경도의 증가를 보였으나 그 변화 정도는 가장 적게 나타났다. SEM 관찰 결과 I, II, III군이 우식 유발 직후나 IV군과 비교하여 표면이 더 균일해지고 불규칙성이 감소된 양상을 보였으며, III군에서 무정형의 피막 형태의 침착이 나타났다. 이러한 결과를 종합해 보면 SDF만을 도포한 군과 SDF와 NaF, SDF와 KI를 함께 도포한 경우 모두 표면 형태가 균일해지고 미세경도가 증가하였으며 이와 같은 결과를 기반으로 구강 내의 환경에서도 재광화 효과를 가질 수 있을 것으로 사료되었다. 또한 이 연구의 제한된 조건 하에서 NaF 바니쉬를 사용하였을 때에는 SDF의 재광화 효과를 증가시키지 못했으며, SDF와 KI를 함께 도포한 경우 SDF의 재광화가 효과가 증가되는 결과를 보였으나 추후 실제 구강 내에서의 다양한 상황을 고려한 추가적인 연구가 필요할 것으로 생각된다. The purpose of this study was to compare the effect of sodium fluoride(NaF) varnish and potassium iodide(KI) on remineralization efficacy of silver diamine fluoride(SDF) by measuring microhardness and evaluating surface morphology by scanning electron microscope(SEM). Artificial caries lesions were induced on extracted primary molars and vickers microhardness was measured. Specimens were randomly separated into 4 groups for treatment. The specimens in group I were treated with SDF, group II with NaF varnish after SDF, group III with KI after SDF and group IV with distilled water. After 8 days of pH cycling, vickers microhardness was measured and difference before and after treatment was calculated. For SEM, 2 samples were evaluated respectively after enamel polishing, lesion formation and after pH cycling. Group III showed highest increase in microhardness. Group I showed higher increase in microhardness than Group II but without statistical difference. Group IV showed lowest increase in microhardness value among 4 groups. On SEM image, group I, II and III showed smoother and less irregular surface compared to group IV. Amorphous crystal pellicles were observed in group III. In conclusion, SDF, SDF and NaF, SDF and KI groups showed smoother surface and increase in microhardness suggesting the possibility that remineralization effect might take place in oral conditions. In addition, in limited conditions of this study, applying NaF varnish after SDF did not increase the remineralization efficacy of SDF while KI significantly increased the remineralization efficacy of SDF. However, additional study considering various conditions that might affect demineralization and remineralization in clinical situations need to be conducted.

      • KCI등재

        공항산업 동향분석을 위한 텍스트 애널리틱스 모델에 관한 연구

        남승주(Seungju Nam),최솔샘(Solsaem Choi),김준환(Junhwan Kim),김진기(Jin Ki Kim) 한국경영과학회 2020 經營 科學 Vol.37 No.1

        Analyzing current trends and identifying future prospects is one of the important tasks to establish a successful strategy for airport development. In this study, we use latent Dirichlet allocation (LDA), a typical topic modeling technique, to supplement the traditional qualitative methodologies and find a major trend of airport industry. Specifically, we deduct major topic from three different data sources related to airport (academic article, policy study report and news article) and compare each topic to find out the differences of each topic. In addition, we investigate the changing trend in each data source through longitudinal analysis. Our results show that three data sources have distinguishing trends which reflect their own characteristics. We find that most of data usually focus on the future situation for sustainable development rather than concentrating on the current issues. This study suggests a methodology using large amounts of text data to explore future promising trend from sperate data sources and provide insights for stakeholders of airport industry. The analyzing methodology we proposed has also significant meaning in that it can be applied comprehensively for trend analysis of other industry including tourism and hospitality as well as airport industry.

      • 사이버나이프 6-D Skull Tracking의 유용성 평가

        이건호,배선명,송흥권,백금문,Lee, Geon Ho,Bae, Sun Myeong,Song, Heung Kwon,Baek, Geum Mun 대한방사선치료학회 2018 대한방사선치료학회지 Vol.30 No.1

        목 적 : 사이버나이프(Accuray Inc., Sunnyvale, CA)를 이용한 제1, 2경추의 정위체부방사선치료(Stereotactic Body Radiation Therapy, SBRT)시 사용가능한 Xsight Spine Tracking(XST)과 6-Dimensional Skull Tracking(6DST)의 비교를 통해 6DST의 유용성을 평가하고자 한다. 대상 및 방법 : 2017년 1월부터 9월까지 본원에서 사이버나이프를 이용하여 제1, 2경추에 SBRT를 진행한 환자 9명을 대상으로, 전산화단층촬영장치(Lightspeed VCT 64, General Electric Co. Waukesha, WI, USA)를 이용해서 컴퓨터 단층 영상(Computed tomography) 을 획득한 후 전산화치료계획시스템(Multiplan system Version 4.6, Accuray, US)를 이용해 제 1, 2경추에 대한 XST와 6DST가 가능한 계획을 수립하였다. 1차 영상 유도를 통해 환자 자세를 보정한 후 동일 환자에 대한 XST와 6DST를 순서대로 진행하고 측정된 결과값을 비교 평가하였다. 결 과 : 제1경추를 대상으로 XST을 실시한 후 측정된 6D Couch 의 Y, Z, X 축 값과 Roll, Pitch, Yaw 값 중 최대값은 0.9 mm, 0.9 mm, 0.7 mm과 $1.0^{\circ}$, $1.0^{\circ}$, $1.2^{\circ}$로 측정되었고, 6DST의 경우 0.7 mm, 0.7 mm, 0.9 mm과 $0.5^{\circ}$, $0.9^{\circ}$, $0.8^{\circ}$로 측정되었다. 제2경추의 XST를 실시했을 때 측정된 값 중 최대값은 0.7 mm, 0.7 mm, 0.8 mm과 $0.9^{\circ}$, $1.0^{\circ}$, $1.8^{\circ}$였고, 6DST의 경우 0.9 mm, 0.7 mm, 0.9 mm와 $0.9^{\circ}$, $0.9^{\circ}$, $1.0^{\circ}$로 측정되었다. 결 론 : 이번 연구를 통해서 제 1, 2 경추에 대한 XST와 6DST의 6D Couch 측정값이 모두 본원에서 기준으로 하고 있는 범위 안에서 측정되고 있음을 확인할 수 있었다. 또한 두 방법을 진행하는 과정에서 설정값 변경을 진행해야하는 XST보다 6DST가 영상유도절차를 간소화 시킬 수 있다는 것을 확인할 수 있었다. 따라서 제 1, 2 경추에 대한 SBRT를 진행할 경우 XST와 더불어서 6DST를 사용한다면 정확한 치료와 더불어서 치료 시간을 단축시킬 수 있을 것으로 사료된다. Purpose : The purpose of this study is to evaluate the usefulness of 6 Dimensional Skull Tracking(6DST) in Cyberknife Stereotactic Body Radiation Therapy(SBRT) for the first and second cervical vertebrae(C1 and C2) metastasis. Methode and material : The Computed Tomography (Lightspeed VCT 64, General Electric Co. Waukesha, WI, USA) was used to acquire the CT images of the 9 patients with cervical vertebrae(C1 and C2) metastasis. Treatment plans for Xsight spine tracking and 6 Dimensional skull tracking were established with planning system (Multiplan system Version 4.6, Accuray, US). The results of XST and 6DST for each patient were analyzed with Microsoft Excel 2010. Result : The Maximum offsets of XST for C1 were 0.9 mm in Y(supero-inferior), 0.9 mm in Z(antero-posterior), 0.7 mm in X(left-right) direction, and rotations were and 1.0 degrees roll, 1.0 degrees pitch and 1.2 degrees yaw. The Maximum offsets of 6DST for C1 were 0.7 mm, 0.7 mm, 0.9 mm and $1.0^{\circ}$, $1.0^{\circ}$, $1.2^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw. The Maximum offsets of XST and 6DST for C2 were 0.7 mm, 0.7 mm, 0.8 mm and $0.9^{\circ}$, $1.0^{\circ}$, $1.8^{\circ}$, and 0.9 mm, 0.7 mm, 0.9 mm and $0.9^{\circ}$, $0.9^{\circ}$, $1.0^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw, respectively. Conclusion : XST and 6DST showed identical results for translations and rotations within the tolerance. It is possible to simplify the treatment time and procedure by using the 6DST. Therefore, 6DST is very useful methode with XST among the various tracking methods in Cyberknife for the patients with C1, C2 vertebral metastasis.

      • 폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가

        이건호,강효석,최병준,박상준,정다이,이두상,안민우,전명수,Lee, Geon Ho,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Du Sang,Ahn, Min Woo,Jeon, Myeong Soo 대한방사선치료학회 2017 대한방사선치료학회지 Vol.29 No.2

        Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs. 목 적: 폐에서 VMAT치료는 연속적으로 회전을 하면서 방사선을 조사하므로 정상적인 폐에 저 선량을 증가시킨다. 이로 인해 방사선 부작용 중 방사선 폐렴의 발생률이 증가 할 수 있다. 본 연구에서는 방사선 폐렴의 발생 확률 증가 원인이 되는 폐의 저 선량 영역의 방사선을 줄일 수 있는 H-VMAT 방법을 적용하여 치료를 받은 환자를 대상으로 치료계획별 폐의 저 선량 영역과 주변 정상장기들에 전달되는 방사선량을 비교 분석하여 H-VMAT의 유용성을 평가하고자 하였다. 대상 및 방법: 폐암방사선 치료 환자 중 H-VMAT 방법을 적용한 환자 25명을 대상으로 하였으며, 치료 계획용 용적의 처방선량은 총 선량 44 Gy를 22회 분할 조사로 적용하였다. 각 환자마다 Conventional RT, VMAT, H-VMAT 방법으로 계획을 진행하였다. Conventional RT는 치료계획용적의 크기, 위치, 모양 및 주변장기들의 위치를 고려하여 4~5개 조사야로 치료계획을 진행하였고, VMAT 치료계획의 경우는 $360^{\circ}$를 2번 회전하는 방법과 $180^{\circ}$를 2~3회 회전하는 방법으로 계획하였다. H-VMAT은 폐의 선량 및 주변 장기의 허용선량을 고려하여 VMAT 치료계획에서 2개의 고정조사야를 추가 하여 계획하였다. 결 과: 폐선량은 비소세포성폐암에서 치료계획용적을 제외한 폐의 $V_5$, $V_{10}$은 H-VMAT이 $55.40{\pm}13.39%$, $32.05{\pm}11.37%$로 가장 낮았고, 소세포성폐암에서도 $V_5$, $V_{10}$의 값은 $64.32{\pm}16.15%$, $35.50{\pm}9.91%$로 가장 낮았다. 비소세포성폐암에서 VMAT의 척수 선량은 $21.15{\pm}4.02Gy$로 다른 치료방법과 비교하여 최대 7.94 Gy 차이만큼 낮은 선량이 전달되었고, 소세포성폐암에서는 $19.72{\pm}1.82Gy$로 가장 낮은 선량을 보였다. 심장의 $V_{20}$은 H-VMAT와 VMAT의 비교 결과 VMAT이 최대 16.2 % 더 낮은 값을 보이기도 하였다. 식도에 전달되는 평균선량 역시 소세포성폐암과 비소세포성폐암에서 $17.44{\pm}2.04Gy$, $17.84{\pm}9.20Gy$로 VMAT이 가장 낮았다. 결 론: 주변 정상 장기 선량의 값을 비교해 보았을 때, VMAT에서는 심장, 식도, 척수 등에서 나머지 치료계획보다 더 적은 선량이 전달되는 것을 알 수 있었다. 하지만 척수를 제외한 나머지 장기에서는 H-VMAT과 큰 차이를 보이지 않았다. H-VMAT은 일부 정상 장기의 선량이 증가하였지만 허용선량을 초과하지 않았다. 그리고 폐의 $V_5$, $V_{10}$에서 낮은 값을 보였다. Conventional RT, VMAT, H-VMAT을 비교하였을 때 심장, 식도, 척수 등에 전달되는 선량이 부작용을 발생시킬 수 있는 선량보다 적다면 폐의 저 선량 영역의 장점을 보이는 H-VMAT 방법을 적용함으로써 방사선폐렴의 발생률을 낮출 수 있을 것이라고 사료된다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼