http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
불균일한 클러터 환경 안에서 Nonhomogeneity Detector의 다양한 정규화 방법에 따른 성능 평가
류장희,정지채,Ryu, Jang-Hee,Jeong, Ji-Chai 한국융합신호처리학회 2009 융합신호처리학회 논문지 (JISPS) Vol.10 No.1
This paper describes the performance evaluation of NHD(nonhomogeneity detector) for STAP(space-time adaptive processing) airborne radar according to various normalization methods in the nonhomogeneous clutter environment. In practice, the clutter can be characterized as random variation signals, because it sometimes includes signals with very large magnitude like impulsive signal due to the system environment. The received interference signals are composed of homogeneous and nonhomogeneous data. In this situation, NHB is needed to maintain the STAP performance. The normalization using the NHD result is an effective method for removing the nonhomogeneous data. The optimum normalization can be performed by a representative value considered with a characteristic of the given data, so we propose the K-means clustering algorithm. The characteristic of random variation data due to nonhomogeneous clutters can be considered by the number of clusters, and then the representative value for selecting the homogeneous data is determined in the clustering result. In order to reflect a characteristic of the nonstationary interference data, we also investigate the algorithm for a calculation of the proper number of clusters. Through our simulations, we verified that the K-means clustering algorithm has very superior normalization and target detection performances compared with the previous introduced normalization methods. 본 논문에서는 불균일한 클러터 환경에서 다양한 정규화 방법을 사용한 NHD(nonhomogeneity detector) 기술을 통해 비행체 레이더를 위한 STAP(space-time adaptive processing)의 성능 평가를 수행하였다. 실제로 클러터는 시스템 환경에 따라 임펄스 신호와 같은 신호의 크기가 매우 큰 간섭 신호를 종종 포함하고 있기 때문에 수신된 간섭 신호는 균일한 신호와 불균일한 신호로 구성된다. 이 환경에서 STAP의 성능을 유지하기 위해서는 NHD 기술이 필수적이고, 그 NHD 결과를 이용한 정규화는 불균일한 신호를 제거하는데 효과적인 방법이다. 최적의 정규화는 주어진 데이터의 특성을 잘 고려한 대푯값을 통해서 가능하고, 이에 우리는 K 평균 군집화 알고리즘을 제안한다. 이 알고리즘에서는 군집화에 필요한 묶음의 수를 결정할 때 불규칙한 데이터의 특성을 고려할 수 있게 되고 군집화 된 결과를 이용해 균일한 데이터만을 선택하기 위한 대푯값을 결정할 수 있게 된다. 또한 여기서 우리는 시시각각 변화하는 불규칙적인 데이터의 특성을 잘 반영하기 위해, 적절한 묶음의 수를 결정하기 위한 방법을 연구한다. 시뮬레이션 결과를 통해 K 평균 군집화 알고리즘이 기존의 정규화 방법들에 비하여 매우 우수한 정규화와 목표물 검출 성능을 갖는 것을 확인할 수 있었다.
가부반응 데이터 특성을 가지는 탄약 체계의 신뢰도 추정방법 비교
류장희,백승준,손영갑,Ryu, Jang-Hee,Back, Seung-Jun,Son, Young-Kap 한국군사과학기술학회 2010 한국군사과학기술학회지 Vol.13 No.6
This paper shows accuracy comparison results of reliability estimation methods for one-shot systems such as ammunitions. Quantal-response data, following a binomial distribution at each sampling time, characterizes lifetimes of one-shot systems. Various quantal-response data of different sample sizes are simulated using lifetime data randomly sampled from assumed weibull distributions with different shape parameters but the identical scale parameter in this paper. Then, reliability estimation methods in open literature are applied to the simulated quantal-response data to estimate true reliability over time. Rankings in estimation accuracy for different sample sizes are determined using t-test of SSE. Furthermore, MSE at each time, including both bias and variance of estimated reliability metrics for each method are analyzed to investigate how much both bias and variance contribute the SSE. From the MSE analysis, MSE provides reliability estimation trend for each method. Parametric estimation method provides more accurate reliability estimation results than the other methods for most of sample sizes.
임신오조환자의 뇨 및 혈청중 Human Chorionic Gonadotrophin ( H.C.G ) 의 동태에 관한 면역학적 연구
류장희(CH Yu) 대한산부인과학회 1970 Obstetrics & Gynecology Science Vol.13 No.8
For the immunologic determination of H.C.G. in the patients of hyperemesis gravidarum and evaluation of its titer, basic experiments and semi-quantitative assay had been performed by means of hemagglutination inhibition technique and the obstained results were as following. 1. For the immunization of rabbits, relatively high purity of H.C.G.(5,427IU/mg)was used as antigen and through the effect of additional booster injection of antigen and complete Freund`s adjuvant, high titer of antiserum was obstained. 2. For the evaluation of the specificity of obstained antiserum, weighing technique of immature rat ovary and Ouchterlony method was appllied. The results showed that the used H.C.G. was relatively pure. 3. In the observed patients, primipara occupied 56.7% and the age ranged 22~37, the majority (66.7%) being in 20~30 years range. 4. In Hyperemesis Gravidarum, the titer of H.C.G. in serum and urine were significantly higher than that of normal pregnancy at the same period expect the urinary finding in 11~12wks. 5. The severity of emetic symptoms seemed not exactly correlate with the titer of H.C.G.
류장희(Jang-Hee Ryu),최인상(In-Sang Choi),김주성(Joo-Sung Kim),손영갑(Young Kap Son) 대한기계학회 2011 大韓機械學會論文集A Vol.35 No.10
본 논문은 동적 시스템인 구동기의 강건설계를 수행한 결과를 제시한다. 구동기를 구성하는 부품들의 변량은 구동기의 성능에 변량을 유발한다. 따라서 부품들의 변량에 둔감한 구동기의 성능을 확보하기 위해 구동기에 대해서 강건설계를 수행하였다. 구동기를 구성하는 부품들을 전달함수로 표현하여 시뮬링크 모델로 구축하였으며, 시뮬링크 모델을 이용하여 설계 변수 조합에 따른 구동기의 응답을 얻었다. 또한 반응표면법을 적용하여 구동기의 응답을 설계 변수들의 2차 함수로 근사화하였다. 구동기 응답을 출력으로 하는 근사화된 모델에 확률적 설계방법을 적용하여 강건한 구동기의 성능을 위한 최적 설계변수를 결정하고 기존 설계와 비교한 결과를 제시하였다. This paper shows the robust design results of an actuator, a kind of dynamic system. Variations in the components comprising the actuator cause uncertainties in the system's dynamic performance. Therefore, a probabilistic design method is applied to ensure robust actuator performance to component variation. A Simulink model for the actuator was built using transfer functions for the components. The dynamic responses of the actuator were evaluated using the Simulink model. Performance indexes were approximated as quadratic functions of the design parameters through the application of the response surface methodology (RSM) with the Simulink model. Then, a probabilistic design method was applied to the approximated performance indexes to obtain optimal design parameters that would provide robust actuator performance. The optimal design was compared to the present design in terms of the performance indexes and dynamic response characteristics over time.