RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Effects of graphite additives in electrolytes on the microstructure and corrosion resistance of Alumina PEO coatings

        Guo-Hua Lv,Huan Chen,Wei-Chao Gu,Wen-Ran Feng,Li Li,Er-Wu Niu,Xian-Hui Zhang,Si-Ze Yang 한국물리학회 2009 Current Applied Physics Vol.9 No.3

        In the present work, graphite grains of different sizes were added into the electrolyte to prepare ceramic coatings on aluminum by plasma electrolytic oxidation (PEO). Scanning electron microscopy (SEM) coupled with an energy dispersive X-ray analysis system (EDX), Raman spectroscopy and X-ray diffractometer (XRD) were used to characterize the coatings. A three-electrode system was used to evaluate the corrosion performances of the coatings in a 3.5 wt.% NaCl solution. It was found that the morphology and corrosion performance of the coatings were significantly influenced by the size of the graphite grains. Compared with bigger graphite grains, finer ones were involved in the oxidation process and embedded within the ceramic coatings, which made the coatings less porous and more compact. Thus, the corrosion resistance of the coatings with embedded graphite grains was greatly improved. In the present work, graphite grains of different sizes were added into the electrolyte to prepare ceramic coatings on aluminum by plasma electrolytic oxidation (PEO). Scanning electron microscopy (SEM) coupled with an energy dispersive X-ray analysis system (EDX), Raman spectroscopy and X-ray diffractometer (XRD) were used to characterize the coatings. A three-electrode system was used to evaluate the corrosion performances of the coatings in a 3.5 wt.% NaCl solution. It was found that the morphology and corrosion performance of the coatings were significantly influenced by the size of the graphite grains. Compared with bigger graphite grains, finer ones were involved in the oxidation process and embedded within the ceramic coatings, which made the coatings less porous and more compact. Thus, the corrosion resistance of the coatings with embedded graphite grains was greatly improved.

      • KCI등재

        Investigation of plasma electrolytic oxidation process on AZ91D magnesium alloy

        Guo-Hua Lv,Huan Chen,Li Li,Er-Wu Niu,Huan Pang,Bin Zou,Si-Ze Yang 한국물리학회 2009 Current Applied Physics Vol.9 No.1

        Ceramic coatings oxidized for different time periods were prepared to characterize the plasma electrolytic oxidation (PEO) process of AZ91D magnesium alloy. The coatings were analyzed using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscope and potentiodynamic polarization measurement. The results show that the PEO coatings perform different growth behaviors at different PEO stages, and different morphologies are exhibited on α- and β-phase of Mg substrate. The corrosion resistance measurement predicates that within the first 30 min oxidation, coating oxidized for 20 min is the best corrosion resistant. Ceramic coatings oxidized for different time periods were prepared to characterize the plasma electrolytic oxidation (PEO) process of AZ91D magnesium alloy. The coatings were analyzed using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscope and potentiodynamic polarization measurement. The results show that the PEO coatings perform different growth behaviors at different PEO stages, and different morphologies are exhibited on α- and β-phase of Mg substrate. The corrosion resistance measurement predicates that within the first 30 min oxidation, coating oxidized for 20 min is the best corrosion resistant.

      • KCI등재

        Simultaneous Single-Position Lateral Lumbar Interbody Fusion Surgery and Unilateral Percutaneous Pedicle Screw Fixation for Spondylolisthesis

        Hui Lv,Yu Sheng Yang,Jian Hong Zhou,Yuan Guo,Hui Chen,Fei Luo,Jian Zhong Xu,Zhong Rong Zhang,Ze Hua Zhang 대한척추신경외과학회 2023 Neurospine Vol.20 No.3

        Objective: To evaluate the clinical and radiological efficacy of a combine of lateral single screw-rod and unilateral percutaneous pedicle screw fixation (LSUP) for lateral lumbar interbody fusion (LLIF) in the treatment of spondylolisthesis. Methods: Sixty-two consecutive patients with lumbar spondylolisthesis who underwent minimally invasive (MIS)-TLIF with bilateral pedicle screw (BPS) or LLIF-LSUP were retrospectively studied. Segmental lordosis angle (SLA), lumbar lordosis angle (LLA), disc height (DH), slipping percentage, the cross-sectional areas (CSA) of the thecal sac, screw placement accuracy, fusion rate and foraminal height (FH) were used to evaluate radiographic changes postoperatively. Visual analogue scale (VAS) and Oswestry Disability Index (ODI) were used to evaluate the clinical efficacy. Results: Patients who underwent LLIF-LSUP showed shorter operating time, less length of hospital stay and lower blood loss than MIS-TLIF. No statistical difference was found between the 2 groups in screw placement accuracy, overall complications, VAS, and ODI. Compared with MIS-TLIF-BPS, LLIF-LSUP had a significant improvement in sagittal parameters including DH, FH, LLA, and SLA. The CSA of MIS-TLIF-BPS was significantly increased than that of LLIF-LSUP. The fusion rate of LLIF-LSUP was significantly higher than that of MIS-TLIF-BPS at the follow-up of 3 months postoperatively, but there was no statistical difference between the 2 groups at the follow-up of 6 months, 9 months, and 12 months. Conclusion: The overall clinical outcomes and complications of LLIF-LSUP were comparable to that of MIS-TLIF-BPS in this series. Compared with MIS-TLIF-BPS, LLIF-LSUP for lumbar spondylolisthesis represents a significantly shorter operating time, hospital stay and lower blood loss, and demonstrates better radiological outcomes to maintain lumbar lordosis, and reveal an overwhelming superiority in the early fusion rate.

      • KCI등재

        Relative Abundance of a Vector of Scrub Typhus, Leptotrombidium sialkotense, in Southern Yunnan Province, China

        Yan Lv,Xian-Guo Guo,Dao-chao Jin,Wen-Yu Song,Rong Fan,Cheng-Fu Zhao,Zhi-Wei Zhang,Ke-Yu Mao,Yun-Ji Zou,Zhi-Hua Yang 대한기생충학ㆍ열대의학회 2020 The Korean Journal of Parasitology Vol.58 No.2

        The chigger mite Leptotrombidium sialkotense is one of the 6 main vectors of scrub typhus in China. Before present study, L. sialkotense was found in some parts of Hunan province, China with a narrow geographical distribution. During field investigation 2016-2017, we found L. sialkotense in Jingha, southern Yunnan, China. Of 15 small mammal host species, L. sialkotense were collected from 6 species of the hosts. Rattus brunneusculus was a dominant host of L. sialkotense, from which 98.3% of the mites were collected. The chigger mite showed a relatively high infestation prevalence (PM=11.7%) and mean abundance (MA=0.5) in comparison with the rest 5 host species. These results reveal a certain host specificity of L. sialkotense to a rat R. brunneusculus. The mite L. sialkotense showed an aggregated distribution on the host (P<0.05). A positive correlation observed between L. sialkotense and the body length of hosts. There was a positive interspecific association between L. sialkotense and 2 other dominant vectors, L. deliense and L. scutellare.

      • KCI등재

        Chinoketides A and B, Two New Antimicrobial Polyketides from the Endophytes of Distylium chinense with the "Black-Box" Co-culture Method

        Meng-Meng Lv,Ming-Hui Tan,Li-Wen Lu,Rong-Hua Zhang,Zhi-Yong Guo,Cheng-Xiong Liu,Jin Yang,Kun Zou,Peter Proksch 한국생약학회 2018 Natural Product Sciences Vol.24 No.3

        Two new polyketides, chinoketides A and B (1 - 2) with a known compound xylarphthalide A (3), were isolated from the solid medium of the endophytes from the leaves of the relic plant Distylium chinense with the "black-box" co-culture method, and the structures of two new compounds were elucidated by NMR, MS and CD spectra. And the absolute configurations of chinoketides A (1) and B (2) were determined as 2R,3R,8S and 5R,6S by calculating their ECD spectra to compare with the experimental CD spectra. Finally, the antimicrobial activities were evaluated to Erwinia carotovora sub sp. Carotovora (Jones) Bersey et al, and the results showed that compounds 1 - 3 displayed the antimicrobial activities with MIC value at 20.5, 30.4 and 10.2 mg/mL.

      • Prediction Models for Solitary Pulmonary Nodules Based on Curvelet Textural Features and Clinical Parameters

        Wang, Jing-Jing,Wu, Hai-Feng,Sun, Tao,Li, Xia,Wang, Wei,Tao, Li-Xin,Huo, Da,Lv, Ping-Xin,He, Wen,Guo, Xiu-Hua Asian Pacific Journal of Cancer Prevention 2013 Asian Pacific journal of cancer prevention Vol.14 No.10

        Lung cancer, one of the leading causes of cancer-related deaths, usually appears as solitary pulmonary nodules (SPNs) which are hard to diagnose using the naked eye. In this paper, curvelet-based textural features and clinical parameters are used with three prediction models [a multilevel model, a least absolute shrinkage and selection operator (LASSO) regression method, and a support vector machine (SVM)] to improve the diagnosis of benign and malignant SPNs. Dimensionality reduction of the original curvelet-based textural features was achieved using principal component analysis. In addition, non-conditional logistical regression was used to find clinical predictors among demographic parameters and morphological features. The results showed that, combined with 11 clinical predictors, the accuracy rates using 12 principal components were higher than those using the original curvelet-based textural features. To evaluate the models, 10-fold cross validation and back substitution were applied. The results obtained, respectively, were 0.8549 and 0.9221 for the LASSO method, 0.9443 and 0.9831 for SVM, and 0.8722 and 0.9722 for the multilevel model. All in all, it was found that using curvelet-based textural features after dimensionality reduction and using clinical predictors, the highest accuracy rate was achieved with SVM. The method may be used as an auxiliary tool to differentiate between benign and malignant SPNs in CT images.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼