http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Pilot-sclae EFC (Electric Fume Collector)를 활용한 섬유업체 텐타공정 배출가스에서 악취제거
황열순,박희재,정구희,김덕현,나병기 한국냄새환경학회 2011 실내환경 및 냄새 학회지 Vol.10 No.3
Recently, odor and white smoke emitted from textile industry has emerged as a social problem. Most of pollutants from textile industry is due to the emissions from tenter facility, and in many case wet scrubber is widely used for treating this waste gas from tenter facility. However, it is still difficult to improve the environment of textile complex because of low treatment efficiency. For this reason, we carried out the EFC (Electric Fume Collector) pilot test (50 CMM) for removing odorous substances from waste gas emitted from tenter facility. EFC is a kind of wet electrostatic precipitator. As a result of this study, pollutants and white smoke were eliminated effectively and quite large amounts of oil could be recovered.
Full-scale EFC (Electric Fume Collector)를 활용한 텐타공정 배출가스 정화 및 오일 회수
황열순(Yeal Soon Hwang),박희재(Hee Jae Park),정구회(Gu Hoi Chung),김덕현(Duk Hyun Kim),나병기(Byung-Ki Na) 한국청정기술학회 2011 청정기술 Vol.17 No.3
섬유 염색 산업은 공장 주변의 주민들이 악취로 인하여 고통을 받고 있으며 반드시 해결해야할 대기오염 문제이며, 특히 텐타공정에서 발생하는 백연과 악취를 저감하여야 한다. 섬유 염색 산업의 주된 대기 오염물질은 탄화수소로 이루어진 유연제, 가소제, 발수제등을 사용하는 후처리 공정에서 주로 발생한다. 화학물질이 처리된 섬유를 텐타공정에서 건조하는 동안섬유에 포함된 오염물질들이 기화하여 대기로 배출된다. 백연은 주로 1 마이크론 미만의 작은 고상 혹은 액상물질로 이루어져 있으며, 텐타공정에서 발생된 오염물질 분자들이, 이들 입자에 붙어서 상당히 먼 거리까지 이동하며 악취를 유발하게 된다. 텐타공정의 악취를 줄이는 가장 효과적인 방법은 이러한 미세한 오일미스트를 제거하는 것이다. 본 연구에서는 700CMM의 Full-scale EFC (Electric Fume Collector) 운전을 통하여, 악취 및 백연이 효과적으로 제거되었으며 많은 양의 오일을 회수 할 수 있었다. The textile industry is suffered from air pollution problems which must be resolved. In particular, white smoke and odor after the tenter process require abatement. The major air pollution problem in the textile industry occurs during the finishing stages, where various chemicals are used for coating the fabrics. Lubricating oils, plasticizers, and water repellent chemicals are the fabric treatment chemicals. The coated fabrics are cured by heating in tenter facility. In this process, most of air pollutants emitted into the air. White smoke is basically made up of tiny solid or liquid particles of VOCs less than one micron in size. The oil mist can be carried over long distance from their point of origin. The most effective method of removing odor from tenter process is to get rid of tiny oil mist at the emitted gas. For this reason, the full-scale EFC (Electric Fume Collector) of 700 CMM was tested for removing odorous substances emitted from tenter facility. As a result of this study, odor and white smoke can be eliminated effectively and quite large amounts of oil can be recovered.
이정래,황열순,이기승,이건형,김상종 한국미생물학회 1992 미생물학회지 Vol.30 No.3
서해 경기만의 6개 정점을 대상으로 1990년 3월부터 1991년 10월까지 총 8외에 걸처 석유 분해세균의 공간적, 시간적 분포를 조사하였다. 또한, 서로 다른 배양 조건하에서의 해양 세균 군집의 석유 뷴해능도 연구하였다. 연구 기간 중, 종속 영양세균수와 석유분해세균수는 각각 7,000-108,000 CFU/ml, 0-2, 800 MPN/100 ml 로 측정되었다. 석유분해세균의 공간적 분포는 석유 탄화수소의 존제에 의하여 심하게 영향을 받은 것으로 나타났다. 실혐실내 실험에서, 석유 분해는 배양액에 yeast extract, cell free extract 의 첨가 그리고 석유뷴해세균의 접종에 의하여 증진되었다. The spatial and temporal distribution of petroleum-degrading bacteria(PDB) was studied at six sampling sites in Kyeonggi Bay of the Yellow Sea fiom March 1990 to October 1991. In addition, petroleum-degrading potcntial of natural ~iiai-ineb acterial population was studied at different culturc contlitions. During the period o f stutly. thc heterotrophic bacterial number and PDB number were n1e;rsured in the range of 7 000-108.400 CFU/nil. 0-2.800 MPN1100 mi. respectively. The spatial tlistribution of PDB wa\ highly affected by presence of petroleum hydrocarbon. In laboratory cxperirncnt. petrolcu~n biodegradation wac enhanced hy addition of yeast cxtracl. cell free cxtr:~ct. anti rnixctl culture of PI)B.
박용석,황열순,Park, Yong-Seok,Hwang, Yeol-Sun 환경보전협회 2004 환경정보 Vol.26 No.7
산업화가 진행되면서 우리나라에서도 90년대 초반부터 악취문제가 점차 사회적인 관심거리로 등장하게 되었다. 1995년 대기환경보전법상에 휘발성유기화합물질 규제 규정을 신설하였으며 1996년에 여천지역을 환경오염으로 인한 특별대책지역으로 지정하였다.<중략>