http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김정진,김종규,김명석,Kim, Chung-Chin,Kim, Jong-Kyu,Kim, Myung-Suk 대한생리학회 1968 대한생리학회지 Vol.2 No.2
A study was planned to evaluate the effects of removal of the cingulate cortex upon the occurrence of any behavior commonly displayed by the rat, and to compare the effects of cingulectomy with those of removal of the parietal, parieto-occipital, or occipital regions. The subjects were 54 male albino rats (Holtzman strain, body weight $200{\sim}330\;gm$) including 14 rats in which the cingulate gyri between splenium and genu of the corpus callosum were bilaterally ablated by suction (cingulate group), 9 animals which had their parietal cortices (chiefly area 7) partially removed (parietal group), 9 rats whose parietal and occipital regions (chiefly areae 7 & 17), 13 animals in which the occipital cortices (chiefly area 17) were removed bilaterally (occipital group), and 9 normal rats (normal control group). Eighteen observation cages, each of which housed a subject and was provided with food and water ad lib., were arranged in 6 rows on a rack and the behavior of each subject was scanned by an observer at a distance of 1.5 m from the rack. The observer scanned the first and second rows 6 times in 1 min, then proceeded to the 3rd and 4th rows, scanning for another 1 min, and finally to the 5th and 6th rows. The speed of scanning was such that behavioral observations of all of the 18 rats were completed in 3 min, each subject receiving 6 observations. The scanning was repeated every 3 min for 18 min, which constituted one observation session and was followed by a 72 minutes' recess. The whole procedure was repeated through 24 hours so that a total of 576 behavioral observations were made on each subject in 16 observation sessions. Behaviors checked were sleeping, lying, lying and sniffing, standing, standing and sniffing, exploring, eating, drinking, grooming (included were washing, licking, and scratching), and others. Results obtained were as follows: 1. The cingulate group ate significantly more often than the normal control, the parietal, and the parieto-occipital groups. 2. Exploration was significantly less frequent in the cingulate group than in the normal control, the parietal, and the occipital groups. There was, in the case of the cingulate group, a significant negative correlation between the occurrence of eating and the exploratory activity. 3. The general activity, as judged from the value obtained by adding the occurrence of exploration, eating, drinking, grooming, and standing and sniffing, was significantly increased in the cingulate group compared with those of any other groups including the normal control. 4. Though statistically insignificant, the cingulate group slept least often among all the animal groups tested. 5. The parieto-occipital group tended to groom less, and the parietal group to eat less often than the normal control group did, but the difference was not significant. There were no significant differences among all the groups except the cingulate group as regards other behaviors analyzed. Based on the above results, it was inferred that the cingulate cortex exerts an inhibitory influence upon the occurrence of eating and general activity, while it tends to facilitate the occurrence of sleep.
전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가
김정진,장성원,박장흠,이관섭,하동윤,Kim, Jeong Jin,Jang, Seong Won,Park, Jang Heum,Lee, Kwan Seob,Ha, Dong Yoon 대한디지털의료영상학회 2012 대한디지털의료영상학회논문지 Vol.14 No.2
There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.
Al의 열산화 방법을 이용한 AlGaN/GaN 구조의 표면 Al<sub>2</sub>O<sub>3</sub> 패시베이션 효과
김정진,안호균,배성범,박영락,임종원,문재경,고상춘,심규환,양전욱,Kim, Jeong-Jin,Ahn, Ho-Kyun,Bae, Seong-Bum,Pak, Young-Rak,Lim, Jong-Won,Moon, Jae-Kyung,Ko, Sang-Chun,Shim, Kyu-Hwan,Yang, Jeon-Wook 한국전기전자재료학회 2012 전기전자재료학회논문지 Vol.25 No.11
Surface passivation of AlGaN/GaN heterojunction structure was examined through the thermal oxidation of evaporated Al. The Al-oxide passivation increased channel conductance of two dimensional electron gas (2DEG) on the AlGaN/GaN interface. The sheet resistance of 463 ohm/${\Box}$ for 2DEG channel before $Al_2O_3$ passivation was decreased to 417 ohm/${\Box}$ after passivation. The oxidation of Al induces tensile stress to the AlGaN/GaN structure and the stress seemed to enhance the sheet carrier density of the 2DEG channel. In addition, the $Al_2O_3$ films formed by thermal oxidation of Al suppressed thermal deterioration by the high temperature annealing.
가상현실에서 연속적 느린 운동이 노인의 낙상 요인에 미치는 영향
김정진,구슬,이진주,김유신,윤범철,Kim, Jung-Jin,Gu, Seul,Lee, Jin-Ju,Kim, Yu-Shin,Yoon, Bum-Chul 대한물리치료학회 2012 대한물리치료학회지 Vol.24 No.2
Purpose: The purpose of this study was to assess the effects of virtual reality-based continuous slow exercise on muscle strength and dynamic balance capacity, in older adults over 65 years of age. Methods: Twenty-six volunteers were randomly divided into two groups; a Virtual Reality (VR) exercise-group ($67.8{\pm}4.1$ yrs) and a Control group ($65.5{\pm}5.2$ yrs). The VR group participated in eight weeks of virtual reality exercise, utilizing modified Tai-Chi provided by a motion capture system, and the Control group had no intervention. The hip muscle strength and dynamic balance of the members of both the VR group and the Control group were measured at pre- and post-intervention, using a multimodal dynamometer, and backward stepping test, respectively. Results: 1. After the 8-week VR-based exercise, the VR group showed significant improvement of hip strength, compared to the control group: hip extension (p=0.00), flexion (p=0.00), abduction (p=0.00), and adduction (p=0.00). 2. After the 8-week VR-based exercise, the VR group showed significant improvement of dynamic balance capacity as ground reaction force, compared to the control group. Eyes opened backward stepping test: Fx (+) (p=0.00), Fy (-) (p=0.02), Ver (+) (p=0.02) direction. Eyes closed backward stepping test: Fx (+) (p=0.04), Fy (-) (p=0.04), Ver (+) (p=0.03) direction. Conclusion: The VR group showed improvement of their hip muscle strength, and dynamic balance capacity. Therefore VR-based continuous slow exercise would contribute to reducing the risk of falls in the elderly.
The Fabrication of (Ga, Al) As/GaAs Modified Multi-Quantum Well Laser Diode by MOCVD
김정진,강명구,김용,엄경숙,민석기,오환술,Kim, Chung-Jin,Kang, Myung-Ku,Kim, Yong,Eom, Kyung-Sook,Min, Suk-Ki,Oh, Hwan-Sool The Institute of Electronics and Information Engin 1992 전자공학회논문지-A Vol.29 No.9
The Modified Multi-Quantum Well(MMQWAl) structures have been grown by Mental-Organic chemical Vapor Deposition(MOCVD) method and stripe type MMQW laser diodes have been investigated. In the case of GaAs/AlGaAs superlattice and quantum well growth by MOCVD, the periodicity, interface abruptess, Al compositional uniformity and layer thickness have been confirmed though the shallow angle lapping technique, double crystal x-ray diffractometry (DCXD) and photoluminescence (PL) measurement. stripe-type MMQW laser diodes have been fabricated using the process technology of photolithography, chemical etching, ohmic contact, back side removing and cleaving. As the result of the electrical and opticalmeasurement of these laser diodes, we have achieved the series resistance of $1[\Omega}~2{\Omega}$ by current-voltage measurements, the threshold current of 200-300mA by currnt-light measurements and the lasing wavelength of 8000-8400$\AA$ by lasing spectrum measurements.