RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Research on the temperature characteristics of SiPM-based LaBr3(Ce) detectors

        Yu Tao,Guo Siming,Wu Jinjie,An Zhenghua,Qie Xiaoyu,Guo Kaiyue 한국물리학회 2023 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.82 No.1

        When a satellite-borne detector is being ground calibrated, a standard detector is required to determine the monochromatic X-ray beam energy and intensity. For this purpose, a SiPM-based LaBr3(Ce) detector has been developed. The environmental temperature change may substantially afect the performance of the detector, thus afecting the accuracy of the ground calibration results. To study the efect of temperature change on the performance of the LaBr3(Ce) detector, the performance of the LaBr3(Ce) detector was tested with 241Am and 137Cs γ-ray sources in the high- and low-temperature test chambers. The results showed that within the range of – 20 to 40 °C, the energy resolution of the LaBr3(Ce) detector does not change by more than 1%, nor does the peak-to-total ratio of 241Am and 137Cs. The temperature change has little efect on the performance of the LaBr3(Ce) detector, which meets the requirements for use as a beam monitor. However, the peak location of the radioactive source varies signifcantly with temperature, and the diference with the peak location at room temperature is within 17%. To reduce the variation in the gain of the LaBr3(Ce) detector with temperature, it is necessary to optimize the compensation design of the temperature gain to ensure the stability of the detector gain at various temperatures.

      • KCI등재

        Performance study of g-C3N4/carbon black/BiOBr@Ti3C2/MoS2 photocatalytic fuel cell for the synergistic degradation of different types of pollutants

        Guo Huilin,Yu Tingting,Zhao Lei,Qian Jun,Yu Jiahe,Zhang Yu,Teng Yongyue,Zhu Chunshui,Yang Tao,Chen Wenbin,Gong Picheng,Jiang Cuishuang,Gao Changfei,Yang Bing,Yang Chenyu 한국탄소학회 2023 Carbon Letters Vol.33 No.3

        In this study, a bipolar visible light responsive photocatalytic fuel cell (PFC) was constructed by loading a Z-scheme g-C3N4/carbon black/BiOBr and a Ti3C2/MoS2 Schottky heterojunction on the carbon brush to prepare the photoanode and photocathode, respectively. It greatly improved the electron transfer and achieved efficient degradation of organic pollutants such as antibiotics and dyes simultaneously in two chambers of the PFC system. The Z-scheme g-C3N4/carbon black/BiOBr formed by adding highly conductive carbon black to g-C3N4/BiOBr not only effectively separates the photogenerated carriers, but also simultaneously retains the high reduction of the conduction band of g-C3N4 and the high oxidation of the valence band of BiOBr, improving the photocatalytic performance. The exceptional performance of Ti3C2/MoS2 Schottky heterojunction originated from the superior electrical conductivity of Ti3C2 MXene, which facilitated the separation of photogenerated electron–hole pairs. Meanwhile, the synergistic effect of the two photoelectrodes further improved the photocatalytic performance of the PFC system, with degradation rates of 90.9% and 99.9% for 50 mg L−1 tetracycline hydrochloride (TCH) and 50 mg L−1 rhodamine-B (RhB), respectively, within 180 min. In addition, it was found that the PFC also exhibited excellent pollutant degradation rates under dark conditions (79.7%, TCH and 97.9%, RhB). This novel pollutant degradation system is expected to provide a new idea for efficient degradation of multiple pollutant simultaneously even in the dark.

      • Shear resistance of steel–concrete–steel deep beams with bidirectional webs

        Yu-Tao Guo,Xin Nie,Jiansheng Fan,Mu-Xuan Tao 국제구조공학회 2022 Steel and Composite Structures, An International J Vol.42 No.3

        Steel–concrete–steel composite structures with bidirectional webs (SCSBWs) are used in large-scale projects and exhibit good mechanical performances and constructional efficiency. The shear behaviors of SCSBW deep beam members in key joints or in locations subjected to concentrated forces are of concern in design. To address this issue, experimental program is investigated to examine the deep-beam shear behaviors of SCSBWs, in which the cracking process and force transfer mechanism are revealed. Compared with the previously proposed truss model, it is found that a strut-and-tie model is more suitable for describing the shear mechanism of SCSBW deep beams with a short span and sparse transverse webs. According to the experimental analyses, a new model is proposed to predict the shear capacities of SCSBW deep beams. This model uses strut-and-tie concept and introduces web shear and dowel action to consider the coupled multi mechanisms. A stress decomposition method is used to distinguish the contributions of different shear-transferring paths. Based on case studies, a simplified model is further developed, and the explicit solution is derived for design efficiency. The proposed models are verified using experimental data, which are proven to have good accuracy and efficiency and to be suitable for practical application.

      • KCI등재

        Gadolinium- and lead-containing functional terpolymers for low energy X-ray protection

        Yu-Juan Zhang,Xin-Tao Guo,Chun-Hong Wang,Xiang An Lu,De-Feng Wu,Ming Zhang 한국원자력학회 2021 Nuclear Engineering and Technology Vol.53 No.12

        By polymerization of gadolinium methacrylate (Gd (MAA)3), lead methacrylate (Pb(MAA)2) and methylmethacrylate (MMA), Gd and Pb were chemically bonded into polymers. The X-ray shielding performance was evaluated by Monte Carlo simulation method, and the results showed that the more metalfunctional organic monomer, the better the shielding performance of terpolymers. When the X-rayenergy is 65 keV, Gd (MAA)3-containing polymers have better shielding performance than Pb(MAA)2-containing polymers. Gd could compensate for the weak absorption region of Pb. Therefore, polymerscontaining both Gd and Pb enhanced shielding efficiency against X-ray in various low-energy ranges. Forobtaining terpolymers with uniform monomer compositions, the relationship between the monomercomposition of the terpolymers and the conversion level was optimized by calculating the reactivityratios. The value of reactivity ratios of r (Gd (MAA)3/Pb(MAA)2), r (Pb(MAA)2/Gd (MAA)3), r (Gd (MAA)3/MMA), r (MMA/Gd (MAA)3), r (Pb(MAA)2/MMA) and r (MMA/Pb(MAA)2) was 0.483, 0.004, 0.338, 2.508,0.255, 0.029. The terpolymers with uniform monomer composition could be obtained by controlling themonomer compositions or conversion levels. The results can provide new radiation protection materialsand contribute to the improvement in nuclear safety.

      • KCI등재

        Protective effect of hepatocyte-enriched lncRNA-Mir122hg by promoting hepatocyte proliferation in acute liver injury

        Yu Zhenjun,Li Yuhan,Shao Shuai,Guo Beichen,Zhang Mengxia,Zheng Lina,Zhang Kun,Zhou Feng,Zhang Li,Chen Chiyi,Jiang Wentao,Hong Wei,Han Tao 생화학분자생물학회 2022 Experimental and molecular medicine Vol.54 No.-

        Some long noncoding RNAs (lncRNAs), which harbor microRNAs in their gene sequence and are also known as microRNA host gene derived lncRNAs (lnc-MIRHGs), play a dominant role alongside miRNAs, or both perform biological functions synergistically or independently. However, only a small number of lnc-MIRHGs have been identified. Here, multiple liver injury datasets were analyzed to screen and identify the target lncRNA Mir122hg. Mir122hg was mainly enriched in liver tissues with human-mouse homology. In both CCl4-induced acute liver injury and Dgal/LPS-induced fulminant liver failure in mice, Mir122hg was sharply downregulated at the early stage, while a subsequent significant increase was only found in the CCl4 group with liver recovery. Overexpression and silencing assays confirmed that Mir122hg played a protective role in acute injury by promoting hepatocyte proliferation in vivo and in vitro. Consistent with the results of gene enrichment analysis, Mir122hg binding to C/EBPα affected its transcriptional repression, promoted gene transcription of downstream chemokines, Cxcl2, Cxcl3, and Cxcl5, and exerted pro-proliferative effects on hepatocytes through activation of the AKT/GSK-3β/p27 signaling pathway by CXC/CXCR2 complexes. This study identifies a novel lncRNA with protective effects in acute liver injury and demonstrates that the binding of Mir122hg-C/EBPα promotes hepatocyte proliferation via upregulation of CXC chemokine and activation of AKT signaling.

      • KCI등재

        Prediction and Monitoring of the Construction Vibration Effect on an Adjacent Old Long Span Double-Convex Arch Bridge

        Yu-xiong Liang,Qing-song Feng,Mei-zhen Fu,Bi-tao Wu,Jian-fei Lu,Guo-xi Tang 대한토목학회 2022 KSCE JOURNAL OF CIVIL ENGINEERING Vol.26 No.5

        Ground vibrations caused by the construction of impact drilling piles may affect adjacent bridges, so corresponding prediction and monitoring are necessary to ensure the safety of bridges. In this study, the construction near an existing long-span double-convex arch bridge is taken as a case study to investigate different layouts of construction machines emanating harmful ground vibrations to the existing adjacent bridge by numerical simulations and monitoring. The peak acceleration and velocity acquired from numerical simulations, and monitoring were successfully used to implement impact drilling pile construction near the existing bridge. The results show that there are good consistencies between the monitoring and numerical simulation results, and the vibration acceleration of the foundation of abutments and piers are mainly derived from the vibration caused by the construction within a distance of 50 m, while the construction beyond 50 m has little effect on the old bridge. The numbers and locations of machines near the same foundation may have a weakening or strengthening effect on the peak acceleration and velocity due to destructive and constructive interference of waves, which can help to control the effects of the vibrations of the existing adjacent bridge.

      • KCI등재

        Enhanced photocatalytic activity of TiO2/graphene by tailoring oxidation degrees of graphene oxide for gaseous mercury removal

        Yu Guan,Tao Hu,Jiang Wu,Lili Zhao,Fengguo Tian,Wei-Guo Pan,Ping He,Xuemei Qi,Fangqin Li,Kai Xu 한국화학공학회 2019 Korean Journal of Chemical Engineering Vol.36 No.1

        We used a simple method of graphene oxide (GO) preparation with different oxidation levels, and control the properties of the TiO2 nanocrystals by tuning the content and oxidation degree of GO to enhance the photocatalytic performance. During the hydrothermal reaction, reduction of GO, formation of TiO2 and chemical bonds between TiO2 and reduced graphene oxide (RGO) was achieved simultaneously. Characterization results showed that TiO2 properties such as crystalline grain and particle size could be tailored by the amount of functional groups, and that crystallinity was also controlled by GO degrees of oxidation. TiO2/RGO photocatalysts showed great efficiency of mercury oxidation, which reached 83.7% and 43.6% under UV and LED light irradiation, respectively. The effects of crystalline grain size and surface chemical properties on Hg0 removal under LED and UV light irradiation were analyzed. In addition, the properties of the photocatalysts before and after UV illumination were investigated, finding that part of Ti-OH on TiO2 surface transformed to Ti-O-Ti. In a nutshell, this work could provide a new insight into enhancing activity of photocatalysts and understanding the photocatalytic mechanism.

      • SCIESCOPUSKCI등재

        Effect of weaning age on growth performance, feed efficiency, nutrient digestibility and blood-biochemical parameters in Droughtmaster crossbred beef calves

        Tao, Hui,Guo, Feng,Tu, Yan,Si, Bing-Wen,Xing, Yu-Chuan,Huang, De-Jun,Diao, Qi-Yu Asian Australasian Association of Animal Productio 2018 Animal Bioscience Vol.31 No.6

        Objective: The objective of this study was to determine the effect of weaning age on intake, performance, nutrition metabolism and serum parameters of beef calves. Methods: Sixty Droughtmaster crossbred calves were assigned to 5 groups with 12 calves in each group. The calves in control group remained with the dams till the 22-week age, while the calves weaned at 28 d (4 wk), 42 d (6 wk), 56 d (8 wk), and 70 d (10 wk) of age were sent to group 4 wk, group 6 wk, group 8 wk, and group 10 wk, respectively, and then were fed on milk replacer till the 22-week age. Feed intake and body weight and size were record and blood metabolites were measured. And 24 calves of them (6 in each group) were picked randomly for digestion and metabolism trail. Feed, feces and urine sample were taken and measured. Results: Dry matter intake of calves in group 4 wk was significantly lower than those in the remaining groups from wk 17 to 22 (p<0.05). Feed efficiency of the calves was higher in groups 4 wk and 6 wk than those in groups 8 wk and 10 wk from 11 to 13 wk (p<0.05), and calves had higher feed efficiency in group 4 wk, group 6 wk, and group 8 wk than those in group 10 wk from wk 14 to wk 22. Calves in group 4 wk and 6 wk had lower body weight than group 8 wk and group 10 wk and control group at 10-week age (p<0.05) and 13-week age (p<0.05), and calves in group 6 wk had no significant difference in body weight with control group, group 8 wk and 10 wk (p>0.05) but was higher than that of group 4 wk (p<0.05). Calves in group 6 wk had higher final body weight and total gain than group 4 wk, but no difference of total gain with that of groups 8 wk, 10 wk, and control group. And weaning calves at 6-week age brought higher feed efficiency and average daily gain from wk 14 to wk 22, and higher dry matter and organic matter digestibility at 21 wk. Conclusion: It is concluded that the weaning of calves at 6 weeks of age gave positive results.

      • Synthesis and characterization of monodisperse yttrium aluminum garnet (YAG) micro-crystals with rhombic dodecahedron

        Xu, Tao,Yuan, Rui,Xu, Peng-Cheng,Pan, Dong-Jie,Yang, Woochul,Guo, Hai-Bo,Shen, Yu-Fang,Hu, Jian-Feng,Zhang, Zhi-Jun,Zhao, Jing-Tai Elsevier 2018 Journal of alloys and compounds Vol.762 No.-

        <P><B>Abstract</B></P> <P>Uniform, monodisperse yttrium aluminum garnet (YAG) rhombic dodecahedron micro-crystals were synthesized using coprecipitation and hydrothermal methods. The Na<SUB>2</SUB>SO<SUB>4</SUB> as a surfactant was helpful in improving the dispersity of the crystallites and forming well-faceted, micro-sized dodecahedral YAG crystallites. The effect of the reaction time and the solvent has also been studied. The crystal growth mechanism called dissolution/crystallization was determined by analyzing the experimental and simulated results. And the specific well-developed crystal facets in the {110} family have been demonstrated by the theoretical calculation. A higher integrated emission intensity can be achieved for the YAG:Ce crystallites by improving the phase purity, morphology with better developed dodecahedrons, and dispersion. Furthermore, a rather high luminous efficacy (LE = 104.14 lm/W) for the white LED fabricated using the YAG:Ce<SUP>3+</SUP> phosphor prepared in this work was realized. The correlation between the crystal growth, morphology and luminescence properties of YAG crystallites has been established, which exhibits a great importance for the synthesis and application of mono-dispersed YAG crystallites.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Uniform and monodisperse YAG rhombic dodecahedron micro-crystals were synthesized. </LI> <LI> The growth mechanism of YAG rhombic dodecahedron was studied through experimental and computational simulation. </LI> <LI> The correlation between the crystal growth, morphology and luminescence of YAG crystallites was established. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>

      • KCI등재

        Radiological gastrostomy: A comparative analysis of different image-guided methods

        Hong-Tao Hu,Hang Yuan,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Hong-Tao Cheng,Jun-Li Ma,Yan Zhao,Li Jiang,Yu-Qing Zhao,Hai-Liang Li 소화기인터벤션의학회 2021 International journal of gastrointestinal interven Vol.10 No.2

        Background: Radiographic guided percutaneous gastrostomy has become a safe and effective enteral nutrition method for patients who can not eat by mouth. Fluoroscopy, computed tomography (CT) and cone-beam CT have been routinely used clinically. The aim of this study was to compare the advantages and disadvantages of percutaneous gastrostomy using different radiographic guided methods. Methods: We retrospectively analyzed the clinical data of 538 patients undergoing percutaneous gastrostomy in our department. According to the image guidance method used in gastrostomy, the patients were divided into groups A by fluoroscopy guidance, group B by fluoroscopy combined with C-arm CT guidance, and group C with the whole process CT guidance. The gastrostomy success rate, complication rate, procedure time, and patient radiation dose were analyzed in the three groups. Results: Among 538 patients, 534 were successful and the success rates are 94.3%, 99.3%, and 100% in group A, B, and C, respectively (P > 0.05). There were 3 cases occurred postoperative bleeding as serious adverse events and transferred to surgical gastrostomy. The minor complications include local infection, hyperplasia of granulation tissue, tube obstruction or prolapse, and local pain of the ostomy. The minor complication rates were 10.5%, 10.4%, and 7.7% in group A, B, and C, respectively (P > 0.05). The average procedure time was 25.57 ± 5.99 minutes, 29.01 ± 6.63 minutes, and 45.47 ± 8.98 minutes, respectively (χ2 = 87.98, P < 0.001). The average radiation dosage was 27.30 ± 19.27 mGy, 145.07 ± 106.08 mGy, and 2,590.26 ± 1,088.22 mGy, respectively (χ2 = 204.44, P < 0.001). Conclusion: There were no significant differences in the success rates and complication rates of gastrostomy under the three guiding methods. For difficult cases, CT-guided gastrostomy may be a very useful supplemental method.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼