http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Chun, Yoon-Keun,Ha, Joo-hun,Hong-Jung-Woo,Oh, Soo-Myung,Kim, Sung-Soo 경희대학교 동서의학연구소 1999 INTERNATIONAL SYMPOSIUM ON EAST-WEST MEDICINE Vol.1999 No.1
Yoon-Keun Chun¹,Joohun Ha□Hong-Jung Woo□, Soo Myung Oh□,Sung Soo Kim□ ¹Department of Molecular Biology, College of Medicine,²Department of Surgery, college of Medicine,³Department of Internal Medicine, College of Oriental Medicine,and ⁴East-Weat Medical Reserch Institute,Kyung Hee University, Seoul, Korea. The HBV DNA Amounts in Serum Have No relationship with ALT level and Hetergeneous Population Coexits in Chronic Hepatitis B Virus Infection. Proceedings of International Symposium on East-West Medicine, Seoul. 212-230, 1999. -Hepatitis B is caused by hepadnavirus. Hepatitis B virus replicates through 3.5kb pregenomic RNA intermediate which is regulated by core promoter. Pathogenesis of hepatitis B virus has been bilieved the result of host immune response. But recently many studies have reported that high level of viral replication caused by mutation in core promoter might result in severs hepatitis. But these studies were performed in vitro, not in vivo. So there is yet debate about which factor, viral of host factor, is more important in pathogenesis of hepatitis B virus. So we measured real viral replication level in 204 chronic hepatitis B patients by quantifying HBV DNA from sera by our novel PCR-based more sensitive method, and compared these results with ALT level measured from same sera, which indicates liver cell damage. Surprisingly there are no significant correlation between HBV DNA quantity and ALT level. Then we cloned core promoter region. In SSCP, we found that many viral mutants coexist in one patient. Base on SSCP result, we chose main viral core promoter type in each patients, which is thought to determine overall viral replication level in this patient. Main type of core promoter region of each 41 patients were directly sequenced. And with these we measured promoter activity by luciferase assay system and compared promoter activity with on another. We found tha there were some differences in promoter activity according to core promoter sequences. And we constructed replication-competent viral constructs with core promoter from 41 patients and Transfected these into HepG2 cell and measured HBV DNA by southern blot. There were also differences in HBV DNA quantity according to core promoter sequences. On these all results we investigated correlation between the effect of HBV core promoter on viral replication in vitro and HBN DNA quantity, ALT level from sera of each patients. We found there is no significant correlation among them. As a result, we concluded that in determining severity chronic hepatitis B patients, host factors of each patient is more important rather than replicative activity of virus itself.
자가면역 췌장염의 동반증상 없이 발생한 IgG4 연관 경화성 담관염
천송욱 ( Song Wook Chun ),최자성 ( Ja Sung Choi ),강버들 ( Beo Deul Kang ),김유진 ( Yu Jin Kim ),한기준 ( Ki Jun Han ),조현근 ( Hyeon Geun Cho ),오화은 ( Hwa Eun Oh1 ),조재희 ( Jae Hee Cho ) 대한소화기학회 2013 대한소화기학회지 Vol.62 No.1
IgG4-related systemic diseases are characterized by a diffuse or mass forming inflammatory reaction rich in lymphocytes and IgG4-positive plasma cells (lymphoplasmacytic infiltration), fibrosclerosis of variable organs and obliterative phlebitis. They usually involve various organs including the pancreas, bile duct, gallbladder, salivary gland, retroperitoneum, kidney, lung, and prostate. However, most of them are accompanied by autoimmune pancreatitis, and good response to steroid treatment is one of the hallmarks of this disease. We report a case of an 67-year-old man with IgG4 associated sclerosing cholangitis, who was diagnosed by endoscopic retrograde cholangiopancreatography and successfully treated with steroid therapy. (Korean J Gastroenterol 2013; 62:69-74)
Chun, Min Young,Cho, Bum-Joo,Yoo, Sang Ho,Oh, Bumjo,Kang, Ju-Seop,Yeon, Cholog Williams & Wilkins Co 2018 Medicine Vol.97 No.50
<P><B>Abstract</B></P><P>Both extremely long and short sleep durations have been associated with increased risk of numerous health problems. This study examined the association between self-reported sleep duration and reporting of musculoskeletal pain in the adult Korean population.</P><P>This study included data from 17,108 adults aged ≥50 years, obtained from the Korea National Health and Nutrition Examination Survey 2010–2012 and 2013–2015. Self-reported daily hours slept and the presence of musculoskeletal pain in knee joint, hip joint, or low back were examined. Patients were stratified into 5 groups by their sleep duration: ≤5, 6, 7, 8, or ≥9 h. Multivariate logistic regression analysis was performed, adjusting for covariates including age, sex, marital status, smoking, alcohol use, family income level, education, physical exercise, body mass index (BMI), and stress level.</P><P>A U-shaped relationship was observed between the length of sleep duration and the presence of musculoskeletal pain. After adjusting for covariates, sleep duration of ≤5 h or ≥9 h was significantly associated with musculoskeletal pain experienced for more than 30 days over a 3-month period. We also found that the presence of multi-site musculoskeletal pain was significantly higher among those who slept for ≤5 h or ≥9 h than in those who slept for 7 h.</P><P>These findings suggest that either short or long sleep duration is associated with musculoskeletal pain among Korean adults.</P>
Case Reports : A Case of Primary Adenosquamous Carcinoma of the Liver Presented with Liver Abscess
Oh Sang Kwon,Hong Sik Lee,Dong Wook Koh,Young Jig Cho,Yeon Ho Park,Dong Kyu Park,Yong Leul Oh,Jae Hong Seo,Hoon Jai Chun,Sun Ho Um,Sang Woo Lee,Jai Hyun Choi,Chang Duck Kim,Ho Sang Ryu 대한내과학회 2001 The Korean Journal of Internal Medicine Vol.16 No.4
Primary adenosquamous carcinoma of the liver is a very rare type of cholangiocarcinoma and is defined as a cancer containing both squamous and adenomatous components in the same lesion. Recently, we experienced a primary adenosquamous carcinoma of the live
Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture
Oh, Tong-In,Baek, Sang-Min,Lee, Jae-Sang,Woo, Eung-Je,Park, Chun-Jae The Korean Society of Medical and Biological Engin 2005 의공학회지 Vol.26 No.4
We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.
256-Channel Trans-Admittance Scanner with Lesion Estimation Algorithm for Breast Cancer Detection
Oh, Tong-In,Kim, Kyu-Sik,Lee, Jae-Sang,Woo, Eung-Je,Park, Chun-Jae The Korean Society of Medical and Biological Engin 2005 의공학회지 Vol.26 No.4
Breast cancer detection using electrical impedance techniques is based on numerous experimental findings that cancerous tissues have higher electrical conductivity values than normal tissues. Lately, by taking advantage of the structure of current flows underneath a planar probe of array electrodes, a mathematical formula to find lesions from a measured transadmittance map has been derived. In order to experimentally validate its mathematical analysis and the suggested lesion estimation algorithm, we developed a 256-channel trans-admittance scanner (TAS) for probing anomalies underneath a planar array of electrodes. In this paper, we describe the design and implementation of the TAS. Its performance together with the lesion estimation algorithm was evaluated using saline phantoms. Further studies are proposed to validate the system on human subjects.