http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Nakazawa, H.,Uehara, S.,Abe, K.,Abe, K.,Aihara, H.,Akatsu, M.,Asano, Y.,Aulchenko, V.,Aushev, T.,Bahinipati, S.,Bakich, A.M.,Ban, Y.,Banerjee, S.,Bedny, I.,Bitenc, U.,Bizjak, I.,Blyth, S.,Bondar, A.,B Elsevier 2005 Physics letters: B Vol.615 No.1
<P><B>Abstract</B></P><P>We have measured <SUP>π+</SUP><SUP>π−</SUP> and <SUP>K+</SUP><SUP>K−</SUP> production in two-photon collisions using 87.7<SUP>fb−1</SUP> of data collected with the Belle detector at the asymmetric energy <SUP>e+</SUP><SUP>e−</SUP> collider KEKB. The cross sections are measured to high precision in the two-photon center-of-mass energy (<I>W</I>) range between 2.4GeV<W<4.1GeV and angular region |cos<SUP>θ∗</SUP>|<0.6. The cross section ratio σ(γγ→<SUP>K+</SUP><SUP>K−</SUP>)/σ(γγ→<SUP>π+</SUP><SUP>π−</SUP>) is measured to be 0.89±0.04(stat.)±0.15(syst.) in the range of 3.0GeV<W<4.1GeV, where the ratio is energy-independent. We observe a <SUP>sin−4</SUP><SUP>θ∗</SUP> behavior of the cross section in the same <I>W</I> range. Production of <SUB>χc0</SUB> and <SUB>χc2</SUB> mesons is observed in both γγ→<SUP>π+</SUP><SUP>π−</SUP> and γγ→<SUP>K+</SUP><SUP>K−</SUP> modes.</P>
Nakazawa, Isao,Kimura,, Kazuhiro,Ishida, Hitoshi,Hama, Shinichi 통신위성우주산업연구회 2006 Joint Conference on Satellite Communications Vol.2006 No.-
The receiving revel of mobile satellite communication using the communication and broadcasting engineering test satellite(COMETS) was found to a deep fading characteristic when the satellite elevation angle was between 78 and 81 degrees. We conducted a detailed field study on high satellite elevation angle propagation on 2GHz and 2.5GHz bands in urban area there are many high buildings. We measured the receiving level of uplink/downlink transmissions between pseudo-satellite equipment and pseudo-terminal equipment (on-board antenna included). The equipment was set so that the satellite elevation angle from the horizontal was between 70 and 88 degrees. The results showed that left handed circular polarization (LHCP) receiving levels had a characteristic deep fading of 20-30dB due to the signal being reflected off a wall. When the terminal equipment moves near the building wall, we report on the result of review of the validity of the proposed high satellite elevation angle wall reflection model by the analytical result of the receiving level variations.
Development of the Sub Gear for the Scissors Gear System for Automobile Engines
Nakazawa Katsuhito,Nagata Toshihiko,Motooka Naoki 한국분말야금학회 2006 한국분말야금학회 학술대회논문집 Vol.2006 No.1
P/M enables the economical production of components for many kinds of gears. Functionally, the sub gear requires high tooth accuracy and bending fatigue strength. The whole tooth profile was sized after sintering to satisfy the gear tooth accuracy specification. The part was redesigned to reduce machining requirements. The required bending fatigue strength was achieved through appropriate material choice and induction of compressive residual stress by shotpeening after carburizing. The P/M sub gear replaced a forged steel gear, satisfied performance requirements, expanded the use of P/M applications and provided over 30% cost reduction.
Takahiro Nakazawa,Itaru Naitoh,Kazuki Hayashi 대한소화기내시경학회 2012 Clinical Endoscopy Vol.45 No.3
The technique of intraductal ultrasonography (IDUS) of the bile duct with a thin-caliber probe and a ropeway system has provided excellent images of the bile duct and periductal structures and is an easy transpapillary approach. In addition, once the guide wire is inserted into the bile duct, IDUS and transpapillary biopsy after endoscopic retrograde cholangiopancreatography can be performed in a single session. Here, we review the usefulness of IDUS in the diagnosis of cholangiocarcinoma and IgG4-related sclerosing cholangitis.
Endoscopic Approach via the Minor Papilla for the Treatment of Pancreatic Stones
Takahiro Nakazawa,Kazuki Hayashi,Itaru Naitoh,Fumihiro Okumura,Takashi Joh 대한소화기내시경학회 2012 Clinical Endoscopy Vol.45 No.3
Background/Aims: We aimed to evaluate whether the advanced techniques have influenced the minor papilla approach. Methods: We studied the success rate of guide wire insertion by using ordinary techniques and advanced techniques (rendezvous method and precut method) in 30 patients via the minor papilla. We compared the selection of the access routes between before (52 patients) and after (28 patients) the introduction of the Soehendra stent retriever. Results: In 19 out of 30 patients (63%), guide wire insertion via the minor papilla could be achieved by using ordinary techniques. In total, the guide wire could be inserted in 27 patients (90%) by using the advanced techniques. Before introduction of the Soehendra stent retriever, the major papilla approach was chosen in 38 cases (73%), and the minor papilla approach in 14 cases (27%). After introduction of the Soehendra stent retriever, the major papilla approach was used in 26 cases (93%) and the minor papilla in 2 cases (7%). The frequency of selecting the minor papilla approach has significantly decreased (p<0.05). Conclusions: The advanced techniques have contributed to the improvement of endoscopic approaches via the minor papilla, and decreased the frequency of selecting the minor papilla approach.