http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
ACCURACY OF LAMOST DR1 STELLAR PARAMETERS
GAO, HUA,ZHANG, HUA-WEI,XIANG, MAO-SHENG,HUANG, YANG,LIU, XIAO-WEI,LUO, A-LI,ZHANG, HAO-TONG,WU, YUE,ZHANG, YONG,LI, GUANG-WEI,DU, BING The Korean Astronomical Society 2015 天文學論叢 Vol.30 No.2
We adopt the PASTEL catalog combined with SIMBAD radial velocities as a testing standard to validate the stellar parameters (effective temperature $T_{eff}$, surface gravity log g, metallicity [Fe/H] and radial velocity $V_r$) from the first data release (DR1) of The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) survey. After applying data reduction and temperature constraints to the sample obtained by cross-identification, we compare the stellar parameters from DR1 and PASTEL. The results show that the DR1 results are reliable under certain conditions. We derive a dispersion of 110 K, 0.19 dex, 0.11 dex and $4.91kms^{-1}$ in specified effective temperature ranges, for $T_{eff}$, log g, [Fe/H] and $V_r$ respectively. Systematic errors are negligible except for those of $V_r$. In addition, for stars with PASTEL [Fe/H] < -1:5, the metallicities in DR1 are systematically higher than those in PASTEL.
( Yi Guang Wu ),( Zhe Jin ),( Zhong Cheng Xin ),( Wei Dong Song ),( Jing Peng ),( Zhi Chao Zhang ),( Bing Gao ),( Ze Long Kim ) 한국조직공학·재생의학회 2007 조직공학과 재생의학 Vol.4 No.4
The purpose of this experiment is to construct an in vitro model of rabbit penis enlargement using tissue engineering method, and to investigate the efficacy and safety of autologous fibroblast cell seeded to biodegradable scaffold and also to provide a new perspective of clinical application. We observed the growth of GFP transgenic fibroblast cell from SD mouse after transplantation with the biodegradable scaffold by fluorescence microscope. At the second hand, 160 male New Zealand rabbits were divided into four groups; Group A for control; Group B for acellular matrix implanted; Group C for scaffold implanted only; Group D for autologous cultured fibroblast seeded scaffold. Rabbit scrotal skin (4×4 mm) was detached under general anesthesia, and fibroblast (FB) was cultured and proliferated for 2weeks. Cultured cells were seeded into the scaffold and inserted on the between buck`s and dartos fascia of rabbit penis. To assess the efficacy and safety of the cells, we observed for 4months. The FB of rabbit were successfully cultured and confirmed by immunohistochemistry method. In the results of group D, dermal cell seeding group, the penile girth was significantly increased to 22.3% compared to other groups (Group A 0.3%, Group B 12.7%, Group C 14.6% and Group D 22.3%). We checked the results in 2~4 months later. We observed that moderate penile girth increase was gained using the biodegradable scaffold without other side-effects. Therefore, we carefully suggest a new guidance for penile augmentation by the tissue engineering method.
Non-Doped Organic Light-Emitting Diodes with Saturated Red Emission
Fei Xiao,Bing-xian Shao,Huan-rong Wu,Hui-ying Fu,Xiao-yuan Hou,Xin-dong Gao,Yi-qiang Zhan 한국물리학회 2007 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.50 No.2
Non-doped organic light-emitting diodes with saturated red emission were fabricated using 4-(2-(3,3-dicyanomethylene-5,5-dimethyl-1-cyclohexylidene)vinyl)phenyldi(1-naphthyl)amine (DNP-2CN) or 4-(2-(3,3-dicyanomethylene-5,5-dimethyl-1-cyclohexylidene)vinyl)phenyl(1-naphthyl)phe- nylamine (DPN-2CN) as the emitting layer. Different electron-transporting materials, tris(8-hydroxylquinoline) aluminum (Alq$_3$), 2,2',2''-(1,3,5-phenylene)tris[1-phenyl-1$H$-benzimidazole] (TPBI) and 2-(4-biphenyl)-5-(4-tert-butylphenyl)-1,3,4-oxadiazole (PBD), were introduced into the devices for examining their energy level compatibility of DNP-2CN or DPN-2CN. The device with a structure of ITO/ NPB/ DNP-2CN/ BCP/ Alq$_3$/ LiF/ Al showed red emission with $\lambda_{max}$ at 670 nm (CIE coordinates: $x$ = 0.66, $y$ = 0.33) and a high luminance of 438 cd m$^{-2}$ at a driving voltage of 12 V. The device with a structure of ITO/ NPB/ DPN-2CN/ BCP/ Alq$_3$/ LiF/ Al showed a high brightness of 225 cd m$^{-2}$ at a driving voltage of 12 V with $\lambda_{max}$ at 674 nm (CIE coordinates: $x$ = 0.65, $y$ = 0.33).
Xiao-Guang Dong,Li-Bing Gao,Hai-Jun Zhang,Jing Wang,Kai Qiu,Guang-Hai Qi,Shu-Geng Wu 한국축산식품학회 2021 한국축산식품학회지 Vol.41 No.6
This study discriminated fatty acid profile and flavor characteristics of Beijing You Chicken (BYC) as a precious local breed and Dwarf Beijing You Chicken (DBYC) eggs. Fatty acid profile and flavor characteristics were analyzed to identify differences between BYC and DBYC eggs. Four classification algorithms were used to build classification models. Arachidic acid, oleic acid (OA), eicosatrienoic acid, docosapentaenoic acid (DPA), hexadecenoic acid, monounsaturated fatty acids (MUFA), polyunsaturated fatty acids (PUFA), unsaturated fatty acids (UFA) and 35 volatile compounds had significant differences in fatty acids and volatile compounds by gas chromatographymass spectrometry (GC-MS) (p<0.05). For fatty acid data, k-nearest neighbor (KNN) and support vector machine (SVM) got 91.7% classification accuracy. SPME-GC-MS data failed in classification models. For electronic nose data, classification accuracy of KNN, linear discriminant analysis (LDA), SVM and decision tree was all 100%. The overall results indicated that BYC and DBYC eggs could be discriminated based on electronic nose with suitable classification algorithms. This research compared the differentiation of the fatty acid profile and volatile compounds of various egg yolks. The results could be applied to evaluate egg nutrition and distinguish avian eggs.
Yue Sun,Chuang Gao,Yong-Hui Yang,Li-Bing Wu 제어·로봇·시스템학회 2024 International Journal of Control, Automation, and Vol.22 No.1
In this paper, a class of nonlinear systems with sensor faults and uncertainty problem are considered. The proposed control scheme is designed based on backstepping procedure. Additionally, three classes of filters are introduced, a serious of K-filters and an auxiliary filter are used to deal with the unmeasurable system states, and the command filters are adopted to avoid the “differential explosion” problem in backstepping design. Furthermore, the bound estimation method is adopted to estimate the unknown system parameters, partial loss fault of sensor and the upper bound of unknown nonlinear functions. Meanwhile, the proposed scheme reduces the amount of calculations in the controller design and and plays a certain role in saving network resources. Even when the sensor fails, the proposed scheme can ensure that all the signals in the closed-loop system are uniformly and ultimately bounded. Finally, a single-link robot arm example is simulated to show the feasibility of the proposed scheme.
Chen, Yao-Sheng,Xu, Song-Xin,Ding, Yan-Bing,Huang, Xin-En,Deng, Bin,Gao, Xue-Feng,Wu, Da-Cheng Asian Pacific Journal of Cancer Prevention 2013 Asian Pacific journal of cancer prevention Vol.14 No.11
To investigate the cognition of medical professionals when following screening guidelines for colorectal cancer (CRC) and barriers to CRC screening. Between February 2012 and December 2012, an anonymous survey with 19-questions based on several CRC screening guidelines was randomly administered to gastroenterologists, oncologists, general surgeons, and general practitioners in Jiangsu, a developed area in China where the incidence of CRC is relatively high. The average cognitive score was 26.4% among 924 respondents. Gastroenterologists and oncologists had higher scores compared with others (p<0.01 and p<0.01, respectively); doctor of medicine (M.D.) with or without doctor of philosophy (Ph.D.) or holders with bachelor of medical science (BMS) achieved higher scores than other lower degree holders (P<0.05). More importantly, doctors who finished CRC related education in the past year achieved higher scores than the others (p<0.001). The most commonly listed barriers to referring high-risk patients for CRC screening were "anxiety about colonoscopy without anesthesia", "lack of awareness of the current guidelines" and "lack of insurance reimbursement". Lack of cognition was detected among doctors when following CRC screening guidelines for high-risk populations. Educational programs should be recommended to improve their cognition and reduce barriers to CRC screening.