RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Aloe, Gelfoam, Plaster가 골결손부의 신생골 형성에 미치는 영향에 관한 실험적 연구

        최의환,김수관,Choi Eui-Hwan,Kim Su-Gwan 대한영상치의학회 1999 Imaging Science in Dentistry Vol.29 No.2

        Purpose: This study was to evaluate the effects of Aloe. Gelfoam. and Plaster of Paris on bone healing. Materials and Methods: Four experimental defects were created for placement of the three materials in the right femur of dogs. One defect served as an empty control site. The evaluation was performed at 1-. 6-. and 12-weeks by light microscopy and radiographs. Results: Radiographic and histologic examinations showed new bone formation in the presence of Aloe, Gelfoam. and Plaster of Paris and similar bone healing reactions. Conclusion: On the basis of these findings, it was concluded that Aloe, Gelfoam. and Plaster of Paris may be adequate agents for use in bone procurement.

      • SCOPUSKCI등재

        상악동 후벽의 실험적 골결손부에 관한 방사선학적 연구

        최의환,박원길,Choi Eui-Hwan,Park Won-Kyl 대한영상치의학회 1996 Imaging Science in Dentistry Vol.26 No.2

        The purpose of this study was to evaluate the ability of radiographs in detecting experimental bony defect in the posterior wall of the maxillary sinus. For this study, experimentally five skulls were used, the bony defects with a diameter of 5mm were created at different locations in the posterior wall of the right maxillary sinus and the bony defects of 10mm were created at different locations in the posterior wall of th maxillary sinus. Panoramic view, panoramic sinus view, water's view, and computed tomogram were taken and the results analyzed. The obtanined results were as follows: 1. The panoramic view was superior to the panoramic sinus view in detecting the bony defects in the posterior wall of the maxillary sinus. 2. Panoramic view, panoramic sinus view, and waters's view were limitation to the detection of the bony defects in the posterior wall of the maillary sinus. 3. All the bony defects in the posterior wall of the maxillary sinus were excellently visualized on the computed tomogram.

      • SCOPUSKCI등재

        정상 해부학적 구조물에 대한 X-선 영상의 비교 연구

        최향희,최의환,김재덕,Choi Heang-Hee,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1999 Imaging Science in Dentistry Vol.29 No.1

        Purpose: To compare radiographic images of Digora/sup (R)/ system and Ektaspeed Plus film obtained from normal adults. Materials and methods: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. Results: Two film-SPP configurations showed significantly different gray levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items. there were statistically significant difference among five observers(p<0.05). Conclusions: The image quality of enhanced SP images were superior to Ektaspeed Plus film. and Digora system is potentially applicable to clinical diagnosis.

      • SCOPUSKCI등재

        하악골 골염도의 정량적 평가에 관한 비교연구

        박원길,최의환,김재덕,Park Won-Kyl,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1999 Imaging Science in Dentistry Vol.29 No.1

        This study was performed to compare the bone mineral densities measured at mandibular premolar area by copper-equivalent image and hydroxyapatite phantom with those measured at radius by dual energy absorptiometry and to evaluate the clinical usefulness of Digital system with slide scanner, copper-equivalent image, and hydroxyapatite phantom. For experiment. intraoral radiograms of 15 normal subjects ranged from 20 years old to 67 old were taken with copper-step wedge at mandibular premolar area and bone mineral densities calculated by conversion equation to bone mineral density of hydroxyapatite were compared with those measured at radius distal 1/3 area by Hologic QDR-1000. Obtained results as follows: 1) The conversion equation was Y=5.97X-0.25 and its determination coefficient was 0.9967. The coefficient of variation in the measurement of copper-equivalent value ranged from 4% to 8% and showed high reproducibility. 2) The coefficient of variation in the measurement of bone mineral density by the equation ranged from 7% to 8% and showed high reproducibility. 3) The bone mineral densities ranged from 0.35 to 0.79g/cm2 at mandibular premolararea. 4) The correlation coefficient between bone mineral densities at mandibular premolar area and those at radius distal 1/3 area was 0.8965. As summary, digital image analyzing system using copper-equivalent image and hydroxyapatite phantom appeared to be clinically useful to measure the bone mineral density at dental area.

      • SCOPUSKCI등재

        디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구

        김진수,최의환,김재덕,Kim Jin-Soo,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1997 Imaging Science in Dentistry Vol.27 No.1

        The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

      • SCOPUSKCI등재

        두개하악장에 환자의 안면골 비대칭성에 관한 방사선사진상 비교분석

        박원길,최의환,김재덕,Park Won-Kyl,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1994 Imaging Science in Dentistry Vol.24 No.2

        The purpose of this study was to analyze the facial asymmetry of the patients with the craniomandibular disorder. In this study, 50 patients, who have joint clicking and pain, mouth opening limitation, and 40 dental students, Chosun University, who did not posses any restoration and orthodontic treatment, joint clicking and pain, mouth opening limitation, were selected as the control group. Both the control group and the patient group were takened skull P-A, submento-vertex radiogram by standized methods. After that, the deviation and facial asymmetry were measured and analyzed. The results of the this study were as follows: 1. In the Skull P-A radiogram, the width difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 3.35㎜, patient group were 4.51㎜ (P<0.05), the △Cg-Zy-Go: control group were 1.83㎜, patient group were 3.27㎜(P<0.001). 2. In the Skull P-A radiogram, the height difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 131.85㎜, patient group were 188.45㎜(P<0.05), the △Cg-Zy-Go: control group were 1.58㎜, patient group were 2.68㎜(P<0.00l). 3. In the Skull P-A radiogram, the area difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 120.76㎟, patient group were 185.49㎟(P<0.05), the △Cg-Zy-Go: control group were 2.29㎟, patient group were 3.37㎟(p<0.05). 4. In the submento-vertex radiogram, the width difference of control group and patient group measured that the △Mr-Cl-Ia: control group were 1.50㎜, patient group were 2.35㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.75㎜, patient group were 3.17㎜(P<0.05), the △Mr-Go-Ia: control group were 1.96㎜, patient group were 3.24㎜(P<0.001), the △Mr-Cp-Co: control group were 1.74㎜, patient group were 2.73㎜(P<0.05). 5. In the submento-vertex radiogram, the height difference of control group and patient group measured that the △Mr-Cp-Ia: control group were 1.68㎜, patient group were 2.46㎜P<0.05), the △Mr-CI-Ia: control group were 2.38㎜, patient group were 3.74㎜(P<0.05), the △Mr-Co-Ia: control group were 1.63㎜, patient group were 2.80㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.45㎜, patient group were 3.12㎜(P<0.001). 6. In the submento-vertex radiogram, the area difference of control group and patient group measured that the △ Mr-Cp-Ia: control group were 73.17㎟, patient group were 110.16㎟(P<0.05), the △Mr-Cl-Ia: control group were 105.09㎟, patient group were 180.87㎟(P<0.001), the △Mr-Co-Ia: control group were 103.31㎟, patient group were 148.48㎟(P<0.05), the △Mr-Cm-Ia: control group were 97.01㎟, patient group were 167.83㎟(P<0.05), the △Mr-Go-Ia: control group were 104.24㎟, patient group were 205.90㎟(P<0.05).

      • SCOPUSKCI등재

        Digora$\textregistered$ 영상시스템을 이용한 인접면 인공 치아우식병소의 진단능에 관한 연구

        오경란,최의환,김재덕,Oh Kyung-Ran,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1998 Imaging Science in Dentistry Vol.28 No.2

        Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient s exposure time and may increase diagnostic ability through image processing (such as edge enhancement, grey scale conversion, brightness change, and contrast enhancement). And also, it can transmit and storage image information. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries between Conventional radiograph and Digora images(unenhanced image, brightness & contrast controlled image, and edge enhanced image). ROC(Receiver Operating Characteristic) analysis, paired t-tests, and F-tests were done for the statistical evaluation of detectability. The following results were acquired: 1. In Grade I lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.953, 0.933, 0.965, 0.978 (p>0.05). 2. In Grade II lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.969, 0.964, 0.988, 0.994. Among theses areas, there was just statistical significance between Diagnostic abilities of Digora edge enhanced image and Conventional radiograph (p<0.05). 3. In the Interobserver variability, the ROC curve areas of Digora edge enhanced image was lowermost in these areas, regardless of the Carious lesion depths. In conclusion, intraoral indirect digital system, Digora system, has the potential possibility as an alternative of Conventional radiograph in the diagnosis of proximal caries.

      • SCOPUSKCI등재

        하악 과두 과형성증에 관한 방사선학적 연구

        김진수,김영진,최의환,김재덕,Kim Jin-Soo,Kim Young-Jin,Choi Eui-Hwan,Kim Jae-Duk 대한영상치의학회 1995 Imaging Science in Dentistry Vol.25 No.2

        Condylar hyperplasia is a self-limiting condition characterized by a slowly progressing, enlargement of the mandible that results in facial asymmetry and a crossbite malocclusion. The facial asymmetry, open bite or crossbite, and radiographic evidence of an enlarged condyle confirm the diagnosis of condylar hyperplasia. The etiology of the condition is unknown. This condition usually first becomes apparent during the second decade of life, when one condyle continues to grow while the other is no longer active. Radiographically, the condyle may appear enlarged or the neck of the condyle maybe elongated or both may occur, Sometimes, however, no radiographically demonstrable condylar abnormality will be noted. Surgical correction with subcondylar osteotomy is the treatment of choice. We have observed two cases of condylar hyperplasia occurred in the left mandibular condyle of 24-year-old and 35-year-old women. We obtained that two cases were shown the followed results; 1. Clinically, both cases was unilaterally developed on C/C area, with temporomandibular disorders and pain, facial asymetry and malocclusion. 2. Radiographically, hyperplastic mass confined to the condyle. 3. Histopathologically, these cases shown increased hypertrophic region in parts, and lamellated bone with irregular trabeculae.

      • SCOPUSKCI등재

        치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가

        김재덕,김광원,조영곤,김동기,최의환,Kim Jae-Duk,Kim Kwang-Won,Cho Yaung-Gon,Kim Dong-Kie,Choi Eui-Hwan 대한영상치의학회 1999 Imaging Science in Dentistry Vol.29 No.2

        Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼