http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
조범식,김행길 여수대학교 2001 論文集 Vol.16 No.-
High level languages are rapidly becoming the standard programming methodology for embedded microcontrollers (MCUs), even for smaller 8-bit devices. The C language is probably the most widely used HLL(High Level Language) in MCUs, but will in most applications give an increased code size compared to assembly programming. The result is the ATMEL AVR MCU, that in addition to the optimized code size, is a true single cycle RISC (Reduced Instruction Set Computer) machine with 32 general purpose registers (accumulators) running 4-12 times faster than currently used MCUs.
Hot Issue-Q1 2006 국내 ITSoC 산업동향
조범식,이지연,Jo, Beom-Sik,Lee, Ji-Yeon IT-SOC협회 2006 IT SOC magazine Vol.13 No.-
우리나라 Fabless업체들의 1사분기 실적은 올 한 해 전망을 낙관적으로 봐도 될 만한 모습을 보여 주었다. 2006년도 1사분기 평균매출액은 작년 동분기보다 29% 증가한 82억7천만원을 기록했으며, 전체 조사대상 업체의 70%가 전년 동분기보다 매출이 증가한 것으로 나타났다.
조범식,Jo, Beom-Sik IT-SOC협회 2006 IT SOC magazine Vol.11 No.-
2002년 전 세계적으로 350만대의 출하량을 보였던 D-TV는 2005년에는 4,300만대, 2006년에는 6,200만대에 이를 것으로 전망되고 있어 엄청난 증가세를 보여주고 있다. 매출액도 2005년 480억 달러를 넘어서 2009년에는 800억 달러 가까운 시장을 형성할 것으로 기대되고 있다.
조범식,임인영,Jo, Beom-Sik,Im, In-Yeong IT-SOC협회 2005 IT SOC magazine Vol.6 No.-
이번 전시회에서는 특히 핸드폰, PDA등 휴대기기관련 제품이 대세를 이뤄 전시되었으며, IT-SoC협회도 국내 10개 업체를 이끌고 한국관을 구성하여 참가하였다. 삼성전자는 200만 및 130만 화소 CMOS이미지센서, 휴대폰용QVGA급 TFT LCD드라이버 IC 선보였으며, 인텔은 PDA, PMP 등에 사용할 수 있는 프로세서를, TI와 르네사스는 각각 모바일 멀티미디어 프로세서인 오랩, SH모바일 등으로 관심을 끌었다. 이외에도 시그마텔 등 중소 반도체 업체들 대부분도 MP3P 등 휴대용 애플리케이션 반도체로 제조업체의 이목을 집중시켰다.
조범식,Jo, Beom-Sik IT-SOC협회 2005 IT SOC magazine Vol.8 No.-
최근 사회적으로 큰 이슈가 되고 있는 고실업률과는 대조적으로 SoC 기업의 인력난에 대한 문제는 예전부터 재기되어 온 문제이다. 인력 수급에 대한 애로는 이번 조사에서도 여실히 드러나 한 업체당 시급히 충원이 필요한 인력이 평균 학사급 2.2명, 석사급 3.8명, 박사급 0.6명으로 인력부족현상의 심각함을 보여주고 있다. 특히 석사급 인력수급에 가장 큰 애로사항을 느끼고 있는 것으로 드러났다.
조범식,명준표,이진국,윤형규,구정완,김형렬 대한의학회 2018 Journal of Korean medical science Vol.33 No.3
Background: The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Methods: Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007–2009; V, 2010–2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Results: Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M − spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. Conclusion: The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages.