이병흔,진승현,김동은,권영진 한국방재학회 2020 한국방재학회논문집 Vol.20 No.3
In Korea, the use of BIM in designing is consistently increasing, and in line with current situation, it is necessary to find a method that can interconnect the existing fire simulation and BIM. In this study, we suggested an interworking method of Add-on Program that is possible link with BIM, and conducted a case study with existing programs. Further, it was tested by comparing the temperature at any point. Comparing the result of maximum temperature, a difference of approximately 0.3 ℃, 2.4 ℃, and 17 ℃ was observed in case of T-1, T-2, and T-3. The reason of difference was that a human user cannot create the coordinates like a computer when developing the fire model. In the future, there will be consideration to conduct more case studies. 국내의 경우 BIM을 이용한 설계는 지속적으로 증가할 것으로 전망되며, 설계방법이 BIM으로 변경되는 현 실태에 맞춰 기존의 화재 시뮬레이션과 BIM의 연동이 가능한 방안을 모색할 필요가 있다. 본 연구에서는 BIM과 연동이 가능한 Add-on Program의 연동방법과 기존 프로그램과의 Case Study를 진행하였으며 온도 비교를 위해 임의의 지점의 온도를 비교하는 방식으로 테스트를 진행하였다. 최대 온도를 비교한 결과 T-1의 경우 약 0.3 ℃, T-2의 경우 약 2.4 ℃, T-3의 경우 약 17 ℃의 차이를 보였다. 이는 사용자가 화재모델을 구축할 때 컴퓨터와 동일하게 좌표를 작성할 수 없기 때문에 발생하는 차이로 사료되며 향후 다양한 Case Study를 진행할 필요가 있다.
건축물 외장재의 화재확대방지를 위한 보수구법 및 보수재료검토에 관한 연구
이병흔,진승현,박성하,권영진 한국화재소방학회 2019 한국화재소방학회논문지 Vol.33 No.3
In Korea, the results of a field survey on the construction of flammable exterior materials implementedin 2018 revealed that 147,559 buildings belong to this category. It was found that the fire spreading cases in upperand adjacent constructions are about 3,500 per year, the fires of starting in flammable exterior material are about 1,500 peryear. In this study, we investigated the repair method of buildings constructed by flammable exterior material and conductedperformance verification of each repair materials for prevention of similar fire. In the case of the repair method, a methodof reinforcing with a repair material after removing the existing building finishing material and a method of attaching therepair material after performing the face finishing are proposed. In addition, we conducted cone calorimeter tests of 6materials such as fireproof gypsum board, mineral wool, hard urethane foam, ceramic board and ALC panel as dryvitand repairing materials, and investigated basic combustion performance of that materials. 국내의 경우 2018년도에 시행한 가연성 외장재 설치 건축물 현황조사결과 147,559동의 건축물이 이에 해당되는것으로 조사되었으며, 상층부 및 인접건축물로의 화재확대사례는 연간 약 3,500건, 외장재에서 시작한 화재건수는연간 약 1,500건 이상 발생하는 등 의정부 화재, 제천스포츠센터 화재와 같은 유사한 화재발생의 위험성이 내포되어있다. 본 연구에서는 유사한 화재 재발방지를 위해 가연성 외장재가 시공된 건축물의 보수공법에 대해 조사하고 각각의 보수재료 성능검증을 실시하였다. 보수방법의 경우 기존의 건축물 마감재를 제거한 뒤 보수재료로 보강하는방법과 기존 마감재를 제거하지 않고 면고르기를 실시한 뒤 보수재료를 부착하는 방법을 제안했다. 또한 드라이비트및 보수재료로서 방화석고보드, 미네랄 울, 경질우레탄 폼, 세라믹보드, ALC 패널 등 6가지 재료를 대상으로 콘 칼로리미터 시험을 실시하고 해당 재료들에 대한 기초 연소 성능을 조사하였다.