http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
갱년기 여성의 경항통에 대한 홍화 약침 치료의 임상적 고찰
박재연,윤경진,최유진,김민석,유성진,이참결,노정두,이은용,Park, Jae-Yeon,Yun, Kyung-Jin,Choi, You-Jin,Kim, Min-Seok,Yu, Sung-Jin,Lee, Cham-Kyul,Roh, Jeong-Du,Lee, Eun-Yong 대한약침학회 2011 Journal of pharmacopuncture Vol.14 No.4
Objectives: The purpose of this research was to examine the effect of Carthami-Flos Pharmacopuncture on posterior neck pain of menopausal women. Methods: We treated 20 female patients with neck pain patient(45-60 yr) into two groups and treated Group A with Carthami-Flos Pharmacopuncture and common acupuncture and Group B with common acupuncture. The efficacy of treatment was measured by VAS, NDI and MENQOL scores of before and after 30 days to start treatment. Results: Both group A and B represented effective improvement in VAS and NDI of neck pain and MENQOL scores. And group A was more effective than B group statistically. Conclusions: It was suggested that Carthami-Flos Pharmacopuncture treatment might have effect on posterior neck pain treatment of menopausal women.
자가 슬괵건을 이용한 전방 십자 인대 재건술에서 생체 흡수성 간섭 나사와 피질 골편을 이용한 대퇴 터널내 고정
서승석(Seung Suk Seo),유성진(Sung Jin You),최장석(Jang Seok Choi),김영창(Young Chang Kim) 대한슬관절학회 2001 대한슬관절학회지 Vol.13 No.1
Purpose: The purpose of this study is to report the postoperative clinical results after arthroscopic ACL reconstruction using quadrupled hamstring autograft fixed with biodegradable interference screw and bone block in the femoral tunnel. Meterials and Method: Between January and December 1997, we performed an arthroscopic ACL reconstruction with quadrupled hamstring autograft in twenty one patients. To enhance the mechanical stability in the femoral tunnel the graft was fixed with a biodegradable interference screw and cortical bone block which was harvested from the proximal tibial metaphysis. The tibial side of graft was tied at the post of an AO cortical screw. Postoperatively the patients were permitted an accelerated rehabilitation with motion brace. The results were evaluated with IKDC form, complications and radiologic findings. The average follow-up was 36 months. Results: Patient subjective assessment was graded normal in 4, nearly normal in 8, abnormal in 7, severe abnormal in 2. Ligament evaluation was graded normal in 16, nearly normal in 3, abnormal in 1, severe abnormal in 1. Harvest site pathology was graded normal in 16, nearly normal in 4, abnormal in 1. Functional test was graded normal in 6, nearly normal in 8, abnormal in 4, severe abnormal in 3. Radiologic findings showed an average 22% increase in the tibial tunnel diameter. Postoperative complications were one recurrent patholaxity, deep infection and arthrofibrosis required operation in each. Conclusion: Arthroscopic ACL reconstruction using quadrupled hamstring autograft fixed with biodegradable interference screw and bone block in the femoral tunnel provided with excellent ligament stability and permitted the early accelerated rehabilitation.