복층터널 분기부에서의 보강공법(루프형 강선)에 따른 수치해석 연구
이석진,박스칸,이준호,진현식,Lee, Seok Jin,Park, Skhan,Lee, Jun Ho,Jin, Hyun Sik 한국터널지하공간학회 2018 한국터널지하공간학회논문집 Vol.20 No.5
Congestion of the city with the rapid industrial development was accelerated to build complex social infrastructure. And numerous structures have been designed and constructed in accordance with these requirements. Recently, to solve complex urban traffic, many researches of large-diameter tunnel under construction downtown are in progress. The large-diameter tunnel has been developed with a versatile double-deck of deep depth tunnel. For the safe tunnel construction, ground reinforcement methods have been developed in the weakened pillar section like as junction of tunnel. This paper focuses on evaluation of the effects of new developed ground reinforcement methods in double-deck junction. The values of reinforcement determined from the existing and developed methods were compared to each other by numerical simulation. 도심지 교통정체를 해소하고 지상공간 활용도를 높이기 위해 세계 각국에서는 단일 면적에 최대 교통량을 확보할 수 있고 저수공간등 다목적 활용이 가능한 복층 터널 건설이 각국에서 진행되고 있다. 최근 국내에서도 복층터널 시공에 대한 수요가 증가하고 있으며 단일 노선 복층터널뿐만 아니라 지중에서의 분 합류부 및 교차로 시공까지 가능한 네트워크형 복층터널 개발 연구가 진행 중에 있다. 네트워크형 복층터널에서 지중 분기부 및 합류부 시공 시 형성되는 필라부는 복층터널 본선부와 분기터널간의 상호 간섭효과에 의해 응력집중이 발생되는 취약부로 지반조건에 따른 보강공법 적용이 필요하다. 본 논문은 강연선을 사용하여 loop 형태로 필라부를 구속함으로써 다축 방향으로 구속력을 발휘할 수 있는 보강공법을 제시하였다. 이 방법의 검증을 위하여 실제 복층터널 필라 형성부와 복층터널 상하부에서의 분기되는 구간을 각각 모델링하여 수치해석을 수행하였다. 이를 통해 적정 필라폭 확보에 대한 방안을 제시하였고 기존 보강방법과의 비교 및 보강효과에 대한 수치해석적 검증을 수행하여 실제 현장 적용 전 복층터널 분기부 시공방안을 강구하였다.
윤석,이승래,박현구,박스칸 대한토목학회 2012 대한토목학회논문집 C Vol.32 No.5
최근 들어 경제적인 에너지 활용을 위하여 지열에너지 필요성이 증대되고 있다. 특히 보편적으로 사용되고 있는 U자형 지중열교환기보다 열교환 면적이 넓어 더 높은 열 교환 효율을 보이는 코일형 지중열교환기의 적용이 확대되고 있다. 본 논문에서는 다양한 피치 간격에 따른 코일형 지중열교환기의 실험적 연구를 수행하였다. 5m x 1m x 1m 크기의 모형 토조 내에 주문진 모래가 균질하게 조성되었으며 열응답 시험이 수행되었다. 코일형 지중열교환기 내를 순환하는 순환수 온도값을 이용하여 선형 열원 이론과 고리-코일 열원 모델을 적용하여 지반의 열전도도를 도출하였다. 또한 모형 토조 내의 코일에서 일정한 거리의 계측 온도값과 이론해를 비교하였으며 고리-코일 열원 모델이 선형 열원 모델과 원통형 열원 모델보다 코일형 지중열교환기가 설치된 지반의 온도값을 보다 정확하게 예측함을 알 수 있다. The use of energy pile foundation has been increased for economic utilization of geothermal energy. In particular, a coilshaped ground heat exchanger (GHE) is preferred than conventional U-shaped heat exchanger to ensure better efficiency of heat exchange rate. This paper presents experimental results by changing different p itch spaces of spiral coils. Joomunjin sand was filled in a steel box of which the size was 5m x 1m x 1m. Thermal response tests (TRTs) were conducted to measure the ground thermal conductivity with temperatures of circulating water using line source model and ring coil model. Experimental results and analytical solutions were compared to validate the applicability of these models. Rings coil model showed more accurate similar results with experimental data rather than line source model and cylindrical source model.
윤석(Seok Yoon),박스칸(Skan Park),박현구(Hyun-Ku Park),고규현(GyuㅡHyun Go),이승래(Seung-Rae Lee) 한국지열·수열에너지학회 2011 한국지열에너지학회논문집 Vol.7 No.2
This paper presents how to analyze heat transfer characteristics of double-layered soils. Thermal response tests were conducted to measure the ground thermal conductivities of Joomunjm sand and douole layered soils filled in a steel box of which the size is 5m × 1m × 1m. Double-layered soils were composed of Joomunjm sand and Kaoline clay. Each Lhermal conductivity of Joomurym sand and Kaloine clay was measured by using Heat Flow Meter considering different void ratio. The ground thermal conductivity of doubleㅛlayered soils was 15% smaller than that of Joomunjin sand.