http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이정근(J.G. Lee),최석준(S.J. Choi),이세현(H.S. Jung),정희석(H.S. Jung),권기태(K.T. Kwon),박노준(N.J. Park),황명근(M.K. Hwang) 한국조명·전기설비학회 2011 한국조명·전기설비학회 학술대회논문집 Vol.2011 No.11
In this paper, I try to measure the electrical characteristics of PV(photovoltaic) cell for street lighting with solar simulator and simulated with PC1D software. I keep my eye on the characteristics variation of PV cell as a temperature change. Therefore, I try to increase a temperature of controlled block from 10℃ to 60℃ while measuring the PV cell. As a result, A variation caused by voltage have an effect on the efficacy of PV cell. Hence, it is an important variable when a designer plan to make a solar cell for street lighting.
New Method of PD measuring on MV XLPE Cable by Using Prototype Patch Antenna
키아우소 륀(K-S Lwin),신동훈(D-H Shin),임광진(K-J Lim),공태식(T-S Kong),김희동(H-D Kim),박노준(N-J Park),박대희(D-H Park) 대한전기학회 2007 대한전기학회 학술대회 논문집 Vol.2007 No.4
We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the MV XLPE cable with the new type of patch antenna sensor. In this study, we design new kind of patch antenna and make many experiments compare with the existing HFCT sensor on MV XLPE cable in the laboratory. According to our experimental results our new sensor can detect pure PD and wider bandwidth 20㎒ to 70㎒ than HFCT and can easily localized manually on the cable.
PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor
키아우소륀(K-S Lwin),신동훈(D-H Shin),임광진(K-J Lim),공태식(T-S Kong),김희동(H-D Kim),박노준(N-J Park),박대희(D-H Park) 대한전기학회 2007 대한전기학회 학술대회 논문집 Vol.2007 No.4
We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of offline testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.
FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술
신동훈(D-H Shin),이용성(Y-S Lee),양종석(J-S Yang),박노준(N-J Park),박대희(D-H Park) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.10
We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.
MR 및 PAR 타입 LED광원의 광학적특성 평가 및 성능 분석
황명근(M.K. Hwang),이세현(S.H. Lee),정희석(H.S. Jung),권기태(K.T. Kwon),최석준(S.J. Choi),신상욱(S.W. Shin),노재엽(J.Y. Rho),박노준(N.J. Park) 한국조명.전기설비학회 2011 한국조명·전기설비학회 학술대회논문집 Vol.2011 No.11
본 논문에서는 백색 LED를 사용하여 현재 실내에서 사용되는 MR타입과 PAR타입의 LED램프에 대한 최대광도 (MLI) 값들을 비교분석하였다. 그러나 MR 16 및 PAR 30의 경우, KS 규격에 광속(LF)에 대한 값을 제시하고 있지 않는데 이는 램프 뒷 부분에 다이크로익 미러가 부착되어 있으므로 인해서, 가시광선을 일정한 방향으로 집중시키는 투광 개념의 광원으로 광속의 의미가 필요하지 않아서 인 것으로 파악된다. LED를 사용한 MR 16과 PAR 30램프의 전기적특성과 최대광도를 측정하여 기존의 할로겐전구와 비교분석하여 그 차이점을 제시하였다. 이는 앞으로 LED의 광효율 증대로 광 특성 설계자료로 활용될 것으로 본다.