http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
가우시안 잡음 제거를 위한 에지 검출을 활용한 위너 필터
김선열(Seon-Yeol Kim),유송현(Song-Hyun Yu),정제창(Je-Chang Jeong) 대한전자공학회 2018 대한전자공학회 학술대회 Vol.2018 No.11
Noise is added to the image during image acquisition or transmission. The noise causes degradation of image quality due to loss of information. Gaussian noise is representative type of noise. Wiener filer is used to eliminate Gaussian noise. Conventional Wiener filter sometimes cannot remove noise effectively in flat regions due to the properties that preserve edges. In this paper, we propose a Wiener filter using edge detection to eliminate the noise effectively in flat region. Experimental results indicate the proposed algorithm shows better noise reduction performance than the conventional wiener filter.
류선열(Ryu Sun Youl),김종효(Kim, Jong Hyo),오희균(Oh Hee Kyun),윤영수(Yun Young Soo),김건중(Kim Geon Jung),최홍란(Choi Hong Ran) 대한구강악안면외과학회 1988 대한구강악안면외과학회지 Vol.14 No.1
The benign cementoblastoma is a rare odontogenic tumor of mesenchymal origin and is a true neoplasm of cementum which has an unlimited growth potential. The etiology is still unknown and controversial. It is most common in men below 25 years of age and occurs commonly in mandibular premolar-molar area. Clinically, the cementoblastoma is characterized by painless bony expansion and often detected during routine oral examination. Radiologically, it appears as a radiopaque mass surrounded by a thin radiolucent line and associated with the roots of a tooth. Histopathologically, it is characterized by a cellular fibrous stroma and calcified cementum or cementum-like portion which has numerous reversal lines. Because of the unlimited growth potential, complete excision of the tumor with the involved tooth has been recommended. These reports are two cases of benign cementoblastoma occurred in the right mandibular first molar area of 17-year old male patient and in the left mandibular second molar area of 24-year old male patient. They underwent the complete excision of the tumor with the involved teeth. On follow-up check, it revealed good bony healing and no recurrence on the operated sites.
CT 검사 시 산란선 분포에 관한 연구 The Study of Distribution Scatter Ray when Computed Tomography
김기진,이진회,유세종,김정호,서선열,임재동 대한안전경영과학회 2016 대한안전경영과학회 학술대회논문집 Vol.2016 No.04
CT scan 시 X-ray tube는 환자를 중심으로 360° 회전을 하기 때문에 산란선은 모 든 방향에서 발생한다. 임상에서 환자의 피폭을 감소시키기 환자의 흉·복부 전면만을 차폐하고 환자 후면이나 측면에서 발생되는 산란선에 대한 차폐는 시행하고 있지 않 다. 두부(Brain) CT 검사 시 흉부 및 복부에 입사되는 산란선을 ion chamber로 측정 하여 그 분포를 확인하고 두부 CT 검사 시 발생되는 산란선의 분포를 통해 기존 차폐 방법의 적정성을 평가 하고자 한다. 연구결과 gantry angle이 클수록, 전면보다 후면에 서 산란선이 많이 발생했다. 두부 CT 검사 시 발생되는 산란선에 의한 피폭을 최소화 하기 위해 가급적 gantry angle을 작게 줄 수 있도록 환자 두부의 위치를 조정하여 검 사를 하거나 납치마를 이용하여 환자의 흉·복부를 차폐할 경우 전면 뿐 아니라 양 측 면과 후면을 납치마를 이용하여 차폐를 해야 할 것이다.
김기진,이진회,유세종,김정호,서선열,임재동 대한안전경영과학회 2016 대한안전경영과학회 학술대회논문집 Vol.2016 No.04
CT scan 시 X-ray tube는 환자를 중심으로 360° 회전을 하기 때문에 산란선은 모 든 방향에서 발생한다. 임상에서 환자의 피폭을 감소시키기 환자의 흉·복부 전면만을 차폐하고 환자 후면이나 측면에서 발생되는 산란선에 대한 차폐는 시행하고 있지 않 다. 두부(Brain) CT 검사 시 흉부 및 복부에 입사되는 산란선을 ion chamber로 측정 하여 그 분포를 확인하고 두부 CT 검사 시 발생되는 산란선의 분포를 통해 기존 차폐 방법의 적정성을 평가 하고자 한다. 연구결과 gantry angle이 클수록, 전면보다 후면에 서 산란선이 많이 발생했다. 두부 CT 검사 시 발생되는 산란선에 의한 피폭을 최소화 하기 위해 가급적 gantry angle을 작게 줄 수 있도록 환자 두부의 위치를 조정하여 검 사를 하거나 납치마를 이용하여 환자의 흉·복부를 차폐할 경우 전면 뿐 아니라 양 측 면과 후면을 납치마를 이용하여 차폐를 해야 할 것이다.
WRIST TRUE PA와 LATERAL 검사 시 경사보조도구의 유용성 분석
전상현,김갑중,김낙상,서선열,최선욱,전민철 한국융합학회 2020 한국융합학회논문지 Vol.11 No.2
The purpose of this paper is to evaluate the image of the Styrofoam Wedge that can minimize the position change by supporting the wrist during the True PA and lateral examination of the wrist. In 50 people, the gap between the distal radius joint facet and the wrist bone was measured after the wrist True PA and lateral images were obtained using a general examination(vertical), tube angle(vertical:10°, lateral:20°) and Styrofoam Wedge(vertical). When joint spacing was measured in the True PA and lateral images of the wrist, general examination(5.54mm, 9.42mm), tube angle(2.05mm, 5.07mm) and Styrofoam Wedge(1.79mm, 5.46mm) were shown to be small. The smaller the joint spacing, the easier it is to observe that is open. Therefore, True PA and lateral imaging of the wrist Styrofoam Wedge can reduce the distortion of the image and thus acquire images of high diagnostic value. In addition, it may be possible to reduce the deviation caused by the change of patient's position during re-projection. 본 논문은 손목 후전, 측방향 검사 시 손목을 지지하여 자세 변동을 최소화 시킬 수 있는 경사보조도구에 대해 영상 평가하고자 한다. 50명을 대상으로 일반적 검사(수직), 튜브 각도(후전방향:10°, 측방향:20°)와 경사보조도구(수직)를 이용한 손목 후전, 측방향 영상을 획득하여 먼쪽 노뼈 관절면과 손목 뼈와의 간격을 측정하였다. 손목의 후전, 측방향 영상에서 관절 간격을 측정 하였을때 일반적 검사(5.54mm, 9.42mm), 튜브 각도(2.05mm, 5.07mm) 그리고 경사보조도구(1.79mm, 5.46mm) 순으로 관절 간격이 작게 나타났다. 관절 간격이 작을수록 열려진 관찰이 용이하다. 따라서 경사보조도구를 이용한 손목의 후전, 측방향 촬영은 영상의 왜곡을 감소시켜 진단적 가치가 높은 영상을 획득할 수 있고, 재촬영 시 환자 자세 변동에 따라 발생할 수 있는 편차를 감소시킬 수 있을 것으로 사료된다.
건강한 젊은 성인의 가자미근 신장이 앞정강근과 긴종아리근의 근두께와 근 긴장도에 미치는 영향
전효빈,오승원,김선열,황수진,Jeon, Hyo-Bin,Oh, Seong-Won,Kim, Sun-Yeul,Hwang, Su-Jin 대한고유수용성신경근촉진법학회 2021 PNF and Movement Vol.19 No.3
Purpose: The purpose of this study was to investigate the effect of soleus muscle stretching on the muscle thickness and muscle tone of the tibialis anterior and peroneus longus muscles in healthy young adults. Methods: This study was an observational, cross-sectional study design in healthy young adults. Thirty healthy young adults participated in the study. To investigate the effect of agonist elongation on the muscles' antagonist and synergist characteristics, this study conducted the dynamic stretching of the soleus and plantarflexor muscles for 20 seconds. This study measured the muscle thickness and muscle tone of the soleus, tibialis anterior and peroneus longus muscles before stretching, immediately after stretching, and five minutes after stretching. Results: After analysis, the muscle tone of the soleus muscle was significantly decreased immediately after stretching (20.91±2.61Hz) compared to before stretching (21.83±2.78Hz). The muscle tone of the tibialis anterior was significantly decreased both immediately after stretching (21.76±2.73Hz) and five minutes after stretching (21.72±3.25Hz) compared to before stretching (22.61±3.29Hz). The muscle thickness of the soleus muscle was significantly decreased immediately after stretching (2.04±0.52mm) compared to before stretching (2.21±0.51mm) and was significantly increased five minutes after stretching (2.14±0.49mm) compared to immediately after stretching. Conclusion: The results of this study showed the static stretching of the soleus muscle changed the muscle tone of the tibialis anterior, but not of the peroneus longus muscle. This study suggests that the dynamic stretching of the agonist muscle would show meaningful muscle tone change in the antagonist.