RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUS

        Construction failures of masonry and adobe buildings during the 2011 Van earthquakes in Turkey

        Sayin, Erkut,Yon, Burak,Calayir, Yusuf,Gor, Mesut Techno-Press 2014 Structural Engineering and Mechanics, An Int'l Jou Vol.51 No.3

        On October 23, 2011, an earthquake of magnitude 7.0 struck Van, Turkey. This powerful earthquake caused the deaths of 604 people, more than 2,000 injuries, and a considerable loss of property. After this devastating earthquake, on November 9, 2011, another earthquake of magnitude 5.7 occurred. This moderate earthquake caused the deaths of 40 people. Partial and total collapse of the masonry and adobe buildings occurred in the rural areas of Van. In this paper, the acceleration records and response spectrums of the earthquakes were given and the structural deficiencies and reasons of the failures of the rural buildings were evaluated according to the Turkish Seismic Code. The observed failures showed that low quality of structural materials, poor workmanship, lack of engineering services and insufficient detailing of the structural elements are the main reasons of damages.

      • KCI등재

        Evaluation of C. Albicans and S. Mutans adherence on different provisional crown materials

        Gulsum Sayin Ozel,Mehmet Burak Guneser,Ozgur Inan,Ayce Unverdi Eldeniz 대한치과보철학회 2017 The Journal of Advanced Prosthodontics Vol.9 No.5

        PURPOSE. Bacterial adhesion on provisional crown materials retained for a long time can influence the duration for which permanent prosthetic restorations can be healthily worn in the oral cavity. The aim of this study was to compare seven different commonly used provisional crown materials with regard to Streptococcus mutans and Candida albicans surface adhesion. MATERIALS AND METHODS. For each group, twenty specimens of the provisional fixed prosthodontic materials TemDent (Schütz), Imıdent (Imıcryl), Tab 2000 (Kerr), Structur Premium (Voco), Systemp (Ivoclar Vivadent), Acrytemp (Zhermack), and Takilon-BBF (Takilon) were prepared (diameter, 10.0 mm; height, 2.0 mm). Surface roughness was assessed by atomic force microscopy. Each group was then divided into 2 subgroups (n=10) according to the microbial suspensions used: S. mutans and C. albicans. The specimens were incubated at 37°C with S. mutans or C. albicans for seven days. Bacterial adherence on surfaces was assessed using the 2,3-bis[2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) assay. RESULTS. S. mutans showed maximum adhesion to Structur, followed by Systemp, Acrytemp, Takilon, Tab 2000, Imident, and TemDent (P<.05). The highest vital C. albicans adhesion was noted on Takilon, followed by Imident and Tab 2000; the lowest adhesion was noted on Systemp (P<.05). CONCLUSION. The materials showed significant differences in the degree of bacterial adhesion. C. albicans showed higher surface adhesion than S. mutans on provisional crown and fixed partial denture denture materials.

      • SCIESCOPUSKCI등재

        Evaluation of C. Albicans and S. Mutans adherence on different provisional crown materials

        Ozel, Gulsum Sayin,Guneser, Mehmet Burak,Inan, Ozgur,Eldeniz, Ayce Unverdi The Korean Academy of Prosthodonitics 2017 The Journal of Advanced Prosthodontics Vol.9 No.5

        PURPOSE. Bacterial adhesion on provisional crown materials retained for a long time can influence the duration for which permanent prosthetic restorations can be healthily worn in the oral cavity. The aim of this study was to compare seven different commonly used provisional crown materials with regard to Streptococcus mutans and Candida albicans surface adhesion. MATERIALS AND METHODS. For each group, twenty specimens of the provisional fixed prosthodontic materials TemDent ($Sch{\ddot{u}}tz$), Imident (Imicryl), Tab 2000 (Kerr), Structur Premium (Voco), Systemp (Ivoclar Vivadent), Acrytemp (Zhermack), and Takilon-BBF (Takilon) were prepared (diameter, 10.0 mm; height, 2.0 mm). Surface roughness was assessed by atomic force microscopy. Each group was then divided into 2 subgroups (n=10) according to the microbial suspensions used: S. mutans and C. albicans. The specimens were incubated at $37^{\circ}C$ with S. mutans or C. albicans for seven days. Bacterial adherence on surfaces was assessed using the 2,3-bis[2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) assay. RESULTS. S. mutans showed maximum adhesion to Structur, followed by Systemp, Acrytemp, Takilon, Tab 2000, Imident, and TemDent (P<.05). The highest vital C. albicans adhesion was noted on Takilon, followed by Imident and Tab 2000; the lowest adhesion was noted on Systemp (P<.05). CONCLUSION. The materials showed significant differences in the degree of bacterial adhesion. C. albicans showed higher surface adhesion than S. mutans on provisional crown and fixed partial denture denture materials.

      • SCIESCOPUSKCI등재

        In vitro study of fracture strength of provisional crown materials

        Karaokutan, Isil,Sayin, Gulsum,Kara, Ozlem The Korean Academy of Prosthodonitics 2015 The Journal of Advanced Prosthodontics Vol.7 No.1

        PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at $37^{\circ}C$ for 24 hours, and then they were thermocycled (TC, $5000{\times}$, $5-55^{\circ}C$) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (${\alpha}$=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique.

      • KCI등재

        A method for the non-linear and failure load analysis of reinforced concrete frames

        Turgay Cosgun1,Baris Sayin 사단법인 한국계산역학회 2014 Computers and Concrete, An International Journal Vol.14 No.1

        Modern trend in structural design is to use smaller elements in order to ensure several purposes such as economy, functionality and aesthetic in appearance. However, because of decreasing rigidity of the structural elements, the system displacements increases and displacements become an important subject in this kind of structures takes into account both geometrical changes and the carrying capacity of the material after linear-elastic boundary. In this study, a method is proposed to calculate the failure loads and to analyse the reinforced concrete space frame systems. The numerical examples gathered from the literature survey are solved with this method utilising the prepared computer program and the comparable results are presented. The results show that the method is sufficiently accurate.

      • KCI등재

        In vitro study of fracture strength of provisional crown materials

        Isil Karaokutan,Gulsum Sayin,Ozlem Kara 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.1

        PURPOSE The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at 37℃ for 24 hours, and then they were thermocycled (TC, 5000×, 5-55℃) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (α=.05). RESULTS Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CAD-CAM technique offers more advantages than the direct technique.

      • KCI등재

        Effect of surface treatment and luting agent type on shear bond strength of titanium to ceramic materials

        Isil Karaokutan,Gulsum Sayin Ozel 대한치과보철학회 2022 The Journal of Advanced Prosthodontics Vol.14 No.2

        PURPOSE. This study aimed to compare the effect of different surface treatments and luting agent types on the shear bond strength of two ceramics to commercially pure titanium (Cp Ti). MATERIALS AND METHODS. A total of 160 Cp Ti specimens were divided into 4 subgroups (n = 40) according to surface treatments received (control, 50 μm airborne-particle abrasion, 110 μm airborne-particle abrasion, and tribochemical coating). The cementation surfaces of titanium and all-ceramic specimens were treated with a universal primer. Two cubic all-ceramic discs (lithium disilicate ceramic (LDC) and zirconia-reinforced lithium silicate ceramic (ZLC)) were cemented to titanium using two types of resin-based luting agents: self-cure and dual-cure (n = 10). After cementation, all specimens were subjected to 5000 cycles of thermal aging. A shear bond strength (SBS) test was conducted, and the failure mode was determined using a scanning electron microscope. Data were analyzed using three-way ANOVA, and the Tukey-HSD test was used for post hoc comparisons (P < .05). RESULTS. Significant differences were found among the groups based on surface treatment, resin-based luting agent, and ceramic type (P < .05). Among the surface treatments, 50 μm air-abrasion showed the highest SBS, while the control group showed the lowest. SBS was higher for dual-cure resin-based luting agent than self-cure luting agent. ZLC showed better SBS values than LDC. CONCLUSION. The cementation of ZLC with dual-cure resin-based luting agent showed better bonding effectiveness to commercially pure titanium treated with 50 μm airborne-particle abrasion.

      • KCI등재

        Geometric and Material Nonlinear Analysis of Three-dimensional Steel Frames

        Turgay Cosgun1,Baris Sayin 한국강구조학회 2014 International Journal of Steel Structures Vol.14 No.1

        Results obtained through theoretical and empirical studies which examined the nonlinear behaviour of construction membersenabled us to characterize the behaviour of construction systems under external effects more closely. The calculation methodsthat took into consideration the nonlinear behaviour of the construction members and the nonlinear effects of their geometricalvariations had to be developed in order to evaluate these phenomena and to design structures according to their collapse loadprinciple. In the presented study, a computer program was developed for the characterization of structural systems by takinginto consideration the nonlinear conditions of material behaviours under increasing loads and by considering the second-ordereffects. A matrix-replacement method was used as the basis for developing the program, which takes into consideration theeffects of axial forces on the stiffness of the member by using the stability functions and the effects of plastic hinges bysystematically changing the stiffness matrix in each occurrence of the plastic hinges. In the study, based on the results obtainedfrom the examples, which were solved by the developed program, it was identified that the program could yield rapid andreliable results depending on the user-defined values (number of nodes, error limit for the iteration) and it is observed that theresults are consistent with the literature. The obtained results in this study have contributed to capability of converting twodimensional analyses to three-dimensional analysis of stability functions developed.

      • KCI등재
      • KCI등재후보

        The Reconstruction of Nasal Septal Perforation with High Density Porous Polyethylene Covered with Fascia Lata: An Experimental Study on Rabbit Model

        Güven Yildirim,Vedat Onar,Ibrahim Sayin,Suzan Deniz Onol,Tamer Aydin 대한이비인후과학회 2011 Clinical and Experimental Otorhinolaryngology Vol.4 No.3

        Objectives. Evaluation of a new material, high-density porous polyethylene (HDPP), which is covered with fascia lata, for experimental nasal septal perforation closure. Methods. Twenty New Zealand albino rabbits were included and divided into study and control groups. A lateral incision was made from the lateral aspect of the left nares to the incisura nasomaxillaris. After exposure of the cavum nasi,the nasal mucoperichondrium was elevated bilaterally. A full-thickness 0.5×0.5-cm perforation was created over the septum nasi with a No. 11 surgical blade. A fascia lata graft was used for the study group. The HDPP was covered with fascia lata and placed under the elevated mucosa. HDPP without a fascial covering was used in the control group. Four months after the procedure, magnetic resonance imaging was performed to evaluate resorption of the material. The animals were sacrificed, and the nasal septum was completely removed. Macroscopic and histopathological examinations were performed on the nasal septum. Results. All rabbits had survived after the 4-month period. Macroscopically, nine of 10 (90%) perforations were closed in the fascia lata-covered HDPP group. Histopathological examination of these nine rabbits revealed that the continuity of cartilage was disturbed in the perforation areas. Granulation tissue was inverted in areas in which the cartilage continuity was disturbed. The HDPP had remained intact at the edge of the perforation. In the HDPP group, six of 10 implants were still perforated (60%) and four (40%) were closed. The fascia lata-covered HDPP implant had a significantly higher perforation closure rate than that of the HDPP implant alone (P<0.05). Conclusion. In cases of septal perforation, it is better to cover the HDPP implant with fascia lata. This covered implant can be used for the repair of nasal septal perforations. HDPP implants are easy to work with and avoid the increased operative time and morbidity associated with harvesting autografts.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼