http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
( Myung Jin Lee ),( Kye Hyung Kim ),( Jong Youn Yi ),( Su Jin Choi ),( Chung Jong Kim ),( Nak Hyun Kim ),( Kyoung Ho Song ),( Pyoeng Gyun Choi ),( Ji Hwan Bang ),( Wan Beom Park ),( Eu Suk Kim ),( San 대한내과학회 2014 대한내과학회 추계학술대회 Vol.2014 No.1
In Vitro Antiviral Activity of Ribavirin Against Severe Fever with Thrombocytopenia Syndrome Virus Myung Jin LEE1, Kye-Hyung KIM1, Jongyoun YI2, SuJin CHOI1, Chung-Jong KIM1, Nak- Hyun KIM1, Kyoung-Ho SONG1, Pyoeng Gyun CHOI1, Ji-Hwan BANG1, Wan Beom PARK1, Eu Suk KIM1, Sang-Won PARK1, Hong Bin KIM1, Nam Joong KIM1, Myoung- Don OH1 Seoul National University College of Medicine, Korea1, Pusan National University School of Medicine, Korea2 Background: Severe fever with thrombocytopenia syndrome (SFTS) is an emerging infectious disease caused by a novel Bunyavirus, severe fever with thrombocytopenia syndrome virus (SFTSV). No effective antiviral therapy is proven yet, but clinical use of ribavirin (RBV) has been tried. We investigated the antiviral effect of RBV against SFTSV in vitro. Methods: To test for cytotoxicity of RBV, Vero cells were treated with different concentrations of RBV (3.90 to 500 μg/mL, two-fold dilution) and analyzed by cell viability MTS assay 48h post-infection. To determine antiviral activity of RBV against SFTSV, Vero cells were infected with SFTSV strain Gangwon/Korea/2012 at 100 TCID50 (50% tissue culture infective dose) per well in a 96-well plate, and RBV was added at the concentrations showing no or minimal cytotoxicity. Viral RNAs were extracted from the culture supernatants and quantifi ed using one-step real-time reverse transcription- PCR to amplify the partial large segment of SFTSV. Statistical analysis was done by one-way ANOVA with Tukey`s post hoc test. Results: Cytotoxicity due to RBV was not observed at RBV concentration =31.3 μg/ mL. Viral RNAs at 24h post-RBV treatment were reduced with increasing RBV concentrations (1-32 μg/mL), compared with those of mock-treated cells (P <0.01, Figure). Half maximal inhibitory concentration (IC50) of RBV was 3.69 μg/mL at 24h post-RBV treatment. Conclusions: Our study shows that RBV has antiviral effect against SFTSV in a dose-dependent manner. Further studies are required to evaluate the effi cacy of RBV in SFTS.
배드민턴 경기시 선수들의 타구 패턴과 타구의 효율성에 관한 연구
이계산 한국운동역학회 1997 한국운동역학회지 Vol.7 No.1
The purpose of this study was to investigate the point and side out elements, stroke patterns against the service and special stroke that they were influenced in bedminton. In order to this study women's single game was recorded by the video camera. Also, video analysis system was used for this study. The conclusions were as follows ; "A" was mort predominant than "B", her stroke patterns were various, moreover the percentage of each stroke rate was similiar. However in case of "B", she was tendency of rapidly and simple attack pattern. Especially, she was physically fatigue and moment of loss the game balance because of her nonnecessary smash. The stroke return time was short in "A" than "B". This indicated that "A" was mort properly highclear and progressivly attack against the opponent's stroke and more prediction ability than "B". Accordingly the predominent player seems to various in point and side out mothod, sellected the progressive attact method, accurated in stroke skill and show the accurate and fast prediction ability.
골프 드라이버와 아이언 스윙 동작의 운동학적 변인 비교 연구
임태상,이계산 한국운동역학회 1996 한국운동역학회지 Vol.6 No.1
본 연구의 목적은 국내 정상급 PGA 프로 골퍼의 드라이버와 아이언 스윙 동작의 운동학적인 변인을 3차원적으로 분석하여 골프 스윙 동작의 운동학적인 원리를 제시하는 데 있다. 이에 대한 연구결과는 다음과 같다. 스윙 국면별 소요시간은 두 스윙 모두 다운 스윙이 백 스윙의 1/4정도로 나타났고, 어드레스와 임팩트시의 신체중심위치도 거의 차이가 없는 것으로 나타났다. 클럽헤드의 최고속도는 드라이버의 경우 43.23m/s, 아이언은 37.23m/s, 볼의 속도는 각각 65.81m/s, 47.40m/s로 나타났다. 또한 톱 스윙시 어깨 관절의 회전각은 드라이버 스윙이 110.7˚ , 아이언 스윙이 94.2˚ , 고관절의 회전각은 각각 31.5˚ , 17.6˚ 로 나타났다. 한편, 양발 중심의 사이각은 어드레스시 각각 -1.1˚ , -3.4˚ , 톱 스윙시 오른 무릎각은 156.1˚ , 159.6˚ , 임팩트시 왼 무릎각은 151.9˚ , 146.1˚ 로 나타났으며, 코킹각은 각각 87.7˚ , 89.8˚ , 임팩트시에는 150.80˚ , 145.6˚ 로 나타났다. The purpose of this study was to analyze and compare Driver and Iron swing motion performed by PGA professional golfers of supreme class. The subjects of this study were five KPGA professional golfers who had 10 years of career. The experiment for this study was conducted by utilizing two 16mm high speed cameras set at the nominal speed of 250frames/second. The conclusions were : Down swing time was approximately 1/4 of the back swing time, and the COG position was relatively fixed in a location at the instant of address and impact. The maximum velocity of clubhead was 43.23m/s, 37.23m/s, and the ball velocity was 65.81m/s, 47.40m/s. Also, the shoulder angle at the instant of topswing was 110.7˚ , 94.2˚ , and hip angle was 31.5˚ , 17.6˚ . The foot rotation angle at the instant of address was -1.1˚ , -3.4˚ . The right knee angle at the instant of topswing was 156.1˚ , 159.6˚ and the left knee angle at the instant of impact was 151.9˚ , 146.1˚ . The cocking angle at the instant of topswing was 87.7˚ , 89.8˚ and at the instant of impact was 150.8˚ , 145.6˚ . The clubshaft angle at the instant of middownswing was 186.6˚ , 178.1˚ and at the instant of impact was 123.3˚ , 146.8˚ .
Ka 대역 위성방송 서비스를 위한 DVB-S2/SVC 전송방법에 관한 연구
이규진(Lee Kyu-Jin),손원(Sohn Won),이계산(Lee Kye-San),이인기(Lee In-Ki),장대익(Chang Dae-Ik) 한국방송·미디어공학회 2008 한국방송공학회 학술발표대회 논문집 Vol.2008 No.-
이 논문에서는 MPEG-4 SVC 신호를 DVB-S2 전송시스템에 적용하여 Ka대역 위성방송서비스를 제공하는 전송 방안에 대한 연구를 하였다. SVC신호는 계층 수를 2개로 제한하였으며, 이러한 다계층 신호를 DVB-S2 전송시스템에 적용하기 위하여, 성상도상에서 각 계층의 신호를 동기적으로 합치는 Hierarchical 변조방식과 각 계층의 전송스트림을 RF 주파수 상에서 비동기적으로 합치는 방식인 Layered 변조방식을 사용하였다. 각 전송방안에서 변조방식과 채널 부호율을 결합 소스/채널 부호화 방안에 따라 변화시켜 최적의 전송기법을 도출하였다.
공조분야 탄소중립 구현을 위한 외부전기장 적용 공조(HVAC) 필터 모듈 개발 및 성능평가에 관한 연구
이강산(Kang-San Lee),박준수(Junsu Park),김정근(Joeng Guen Kim),이계중(Kye Jung Lee),유정훈(Junghoon You),최종원(Jongwon Choi),황정호(Jungho Hwang) 대한설비공학회 2022 대한설비공학회 학술발표대회논문집 Vol.2022 No.6
공조장치에서는 외부로부터 유입되는 공기 중 먼지를 제거하기 위해 필터를 사용하고 있으며, 필터에 의한 건물 에너지 소비가 큰 것으로 보고되고 있다. 필터의 압력손실은 낮추고 집진효율을 높이기 위해서 섬유를 전기적으로 하전시킨 정전필터가 연구되고 있으나 필터에 먼지가 포집됨에 따라 먼지에 의해 필터의 정전기력이 차단되어 효율이 감소하는 문제점이 있다. 본 연구에서는 이러한 문제점을 해결하기 위해 필터 외부에서 지속적으로 전기장을 형성시켜 압력손실의 증가없이 집진효율을 향상시켰다. 또한 각 필터 층의 섬유경을 다르게 구성한 3중 구조의 필터를 개발하여 필터의 눈막힘 현상을 완화시켰다. 외부전기장이 적용된 3중 구조 필터 모듈의 경우 기존에 사용 중인 2중 구조 필터 모듈에 비해 필터 수명이 27% 증가했고, 에너지소비를 20% 감소시켰다. 또한, 필터의 전체 사용주기 동안에 헤파필터와 유사한 높은 집진효율을 유지하였다. 따라서, 기존 공조장치에 외부전기장 기술을 적용하면 건물의 에너지소비를 줄여 탄소중립에 기여할 수 있을 것으로 기대된다.
지하철 역사 내 실내 공기질 개선을 위한 정전분무 공기청정기의 성능평가
이강산(Kang-San LEE),박준수(Junsu PARK),이길봉(Gilbong LEE),이계중(Kye Jung LEE),조민정(Minjeong CHO),이미혜(Meehye LEE),최종원(Jongwon CHOI) 대한설비공학회 2021 대한설비공학회 학술발표대회논문집 Vol.2021 No.6
지하철 역사 내부에서 발생하는 대표적인 실내공기 오염물질로는 미세먼지, 부유세균, 그리고 휘발성 유기화합물이 있다. 각각의 오염물질을 처리하기 위해서는 필터를 이용한 여과시스템, UV-C를 이용한 살균시스템, 광촉매를 이용한 산화시스템 등 별도의 독립적인 시스템을 도입해야하므로, 높은 설치비용 및 유지 보수비용에 소비자는 부담을 느낄 수 있다. 따라서 본 연구에서는 미세먼지, 부유세균, 휘발성 유기화합물을 동시에 저감시킬 수 있는 물을 이용한 정전분무 기술을 제안한다. 정전분무 시 생산되는 높은 하전을 띈 미세 물 액적은 미세먼지와 직접 충돌 및 전기적 인력에 의한 간접 충돌로 인해 높은 효율로 미세먼지를 집진할 수 있다. 한편, 물을 이용한 정전분무 시 생성되는 수산화 이온은 높은 전기장 환경에서 에너지를 받아 수산화 라디컬로 변함과 동시에 2개의 수산화 라디컬이 반응을 일으켜 과산화수소가 된다. 이렇게 생산된 과산화수소수와 공기 내 산소가 오존으로 변한 이후 물에 흡수된 오존수는 부유세균의 살균과 휘발성 유기화합물의 산화를 유도한다. 본 연구에서는 이러한 가설을 검증하기 위해 정전분무 공기청정기 시작품을 제작하여 서울 지하철역 플랫폼에 적용하여 성능을 평가하였다. 연구 결과 공기청정기 입출구 사이의 PM10, PM2.5, PM1.0의 집진효율은 각각 99.1, 98.7, 93.5%로 측정되었으며, 장시간 운전 결과 지하철 역사 내 미세먼지는 약 40% 가량 저감되는 것을 확인하였다. 또한, 공기청정기 입출구 사이의 총 부유세균은 99.9% 이상, 총 휘발성 유기화합물은 95% 이상 저감시키는 것을 확인하였다.