http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이지신,이상룡,신승권,이성봉,이명재,윤길팔 대한산부인과학회 1996 Obstetrics & Gynecology Science Vol.39 No.6
난관에 발생하는 포상기태는 매우 드문 경우로 저자들은 난관간질부에 발생한 포상기태의 제거 후 hCG추적검사중인 1예를 경험하였기에 문헌고찰과 함께 보고하는 바이다. The ectopic pregnancy refers to a gestation in which the fertilized ovum implants on any tissue other than the mucous membrane lining the uterine cavity. The most common site of ectopic pregnancy is within the fallopian tube including interstitial portion. Moles usually occupy the uterine cavity; they rarely may be located in the oviduct and even in the ovary. Only a few cases of primary hydatidiform mole of the tube have been reported. We reported an extremely rare case of ectopic hydatidiform mole in the interstitial portion of the tube.
이지신,신승권,최호준,양해관,이명재,윤길팔 대한산부인과학회 1995 Obstetrics & Gynecology Science Vol.38 No.7
저자들은 본 성골롬반병원 산부인과에서 자궁 전적출술을 시행하여 확진한 자궁에 발생한 지방평활근종 1예를 경험하였기에 증례보고와 아울러 문헌고찰하는 바이다. Lipoleiomyomas of the uterus are extremely rare and have little attention. They have aroused interest as a consequence of occasional diagnostic confusion with sarcomas and the continuing unresolved dispute for their histogenesis. We experienced a case of lipoleiomyoma of the uterus, so reported with a brief review of the literature and pahologic findings.
하길풍(KP Hah),이대희(DH Lee) 대한산부인과학회 1976 Obstetrics & Gynecology Science Vol.19 No.6
A case of acrdiac acephalic monster associated with single ovum twin was presented . This monster was born by cesarean section, its weight was about 3.0kg. And review of literature was made briefly.
이재관(JK Lee),김종화(JH Kim),강순범(SB Kang),김종환(JW Kim),서경필(KP Suh) 대한산부인과학회 1985 Obstetrics & Gynecology Science Vol.28 No.8
Patients who have had cardiac valve replacement are being seen increasingly often as candidates for antenatal care. The outcome of 23 pregnancies in 14 patients with bioprosthetic cardiac valves is analyzed and reported here. The results were summarized as follows: 1. Twenty three pregnancies in 14 patients with bioprosthetic cardiac valves resulted in 11 healthy, 2 low birth weight infants, 2 spontaneous abortions, 7 elective terminations of pregnancy, and one tubal pregnancy. 2. Pregnancy and labor seemed to have been tolerated relatively well in these patients. 3. There were 3 males and 10 females among the 13 infants born. 4. Birth weights ranged from 2,140 to 3,670g(mean 3,030). 5. Apgar scores at five minutes ranged from 4 to 10 (mean 9.1). 6. There were no instances of congenital malformations, maternal or fetal hemorrhagic complications. 7. There were 4 spontaneous vaginal deliveries, 7 elective vacuum extraction deliveries, 1 elective forcep delivery, and 1 cesarean section. 8. All patients received prophyllactic broad-spectrum antibiotics for infective endocarditis, and no nistances of endocarditis developed. 9. There were no stillbirth, no neonatal deaths, and no maternal deaths. 10. There were 2 instances of thromboembolism; one in the immediate postoperative period, and the other 5 years after valve replacement. All seemed to be unrelated to pregnancy. 11. Anticoagulants were not used in pregnancies which went to term except one patient, in whom coumarin was administered until 6th week of gestation. 12. One pregnancy was complicated with premature labor, one with gestational edema, one with preexisting chronic active hepatitis, five with worsening of cardiac status (one of the five, with newly developed atrial fibrillation). 13. 34.8% of all pregnancies after cardiac valve replacement were unwanted ones, and at the same time preventable `risk factors`.
Gopalan, AI.,Muthuchamy, N.,Lee, KP. Elsevier 2017 Biosensors & bioelectronics Vol.89 No.1
<P><B>Abstract</B></P> <P>A novel non-enzymatic photoelectrochemical (PEC) glucose sensor was first constructed based on the unique two-dimensional (2D) bismuth oxychloride-graphene nanohybrid sheets (BiOCl-G NHS). We have utilized a facile hydrothermal approach for the preparation of BiOCl-G NHS. Results from cyclic voltammetric and differential pulse voltammetric measurements revealed that the BiOCl-G NHS electrode is capable of generating photocurrent for glucose when its surface is irradiated with a light source (wavelength=365nm). The photocurrents produced for the presence of glucose at the bias potential of +0.50V showed a linear dependence on glucose concentration in the range between 0.5 and 10mM and had a detection limit of 0.22mM. The PEC detection of glucose at BiOCl-G NHS was not influenced by the presence of other common interfering species. The glucose levels, as determined by the BiOCl-G NHS sensor, agreed well with those obtained by the commercial glucometers. This novel non-enzymatic PEC glucose sensor exhibited good performances, such as a wider concentration range (500µM-10mM), high sensitivity (1.878µMmM<SUP>−1</SUP> cm<SUP>−2</SUP> (500µM–2mM) and 127.2µMmM<SUP>−1</SUP> cm<SUP>−2</SUP> (2mM–10mM)), good selectivity, reproducibility (RSD=2.4%) and applicability to real sample (human serum).</P> <P><B>Highlights</B></P> <P> <UL> <LI> Bismuth oxychloride-graphene nanohybrid sheets based glucose sensor was constructed. </LI> <LI> A wide linear-detecting range is reported with photoelectrochemical non-enzymatic sensing mode. </LI> <LI> Reports an innovative strategy for non-enzymatic biomolecule detection. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>
Ectopic Gestation 시의 환부의 절제에 따른 hCG치의 감소상황
오세량,한세준,정종일,고성민,이용은,홍관표,김영미 대한산부인과학회 1992 Obstetrics & Gynecology Science Vol.35 No.10
자궁외임신에서 이환된 난관조직을 완전절제하는 수술과 난관을 보존할 수 있는 수술을 시행하여 융모조직으로 부터 생산되는 hCG량과 수술에 따라 hCG량의 감소를 관찰한 결과 다음과 같은 견해를 보였다. 즉 수술후 최초의 hCG량을 알아야만 hCG치가 계속되는 시간을 알 수 있으며 수술후 hCG량을 방사면역측정법으로 최소한 24일까지는 측정하여야 하고 hCG치의 감소 및 소실상황을 관측하여야하는 것으로 추정되었다. A Study was undertaken to determine the length of time serum of β-subunit of human chorionic gonadotropin (β-hCG) could be detected following removal of ectopic pregnancy. The disappearance pattern of β-hCG was almost equal in complete removal of trophoblastic tissue and in conservative surgical treatment. The initial hCG titer is the most significant factor determining the length of time in which positive titers will be detected.