RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Microstructure, Tensile and Fatigue Properties of Al–5 wt.%Mg Alloy Manufactured by Twin Roll Strip Casting

        Joon‑Young Heo,Min‑Seok Baek,Kwang‑Jun Euh,Kee‑Ahn Lee 대한금속·재료학회 2018 METALS AND MATERIALS International Vol.24 No.5

        This study investigated the microstructure, tensile and fatigue properties of Al–5 wt.%Mg alloy manufactured by twin rollstrip casting. Strips cast as a fabricated (F) specimen and a specimen heat treated (O) at 400 °C/5 h were produced andcompared. In the F specimen, microstructural observation discovered clustered precipitates in the center area, while in theO specimen precipitates were relatively more evenly distributed. Al, Al 6 (Mn, Fe), Mg 2 Al 3 and Mg 2 Si phases were observed. However, most of the Mg 2 Al 3 phase in the heat-treated O specimen was dissolved. A room temperature tensile test measuredyield strength of 177.7 MPa, ultimate tensile strength of 286.1 MPa and elongation of 11.1% in the F specimen and167.7 MPa (YS), 301.5 MPa (UTS) and 24.6% (EL) in the O specimen. A high cycle fatigue test measured a fatigue limit of145 MPa in the F specimen and 165 MPa in the O specimen, and the O specimen achieved greater fatigue properties in allfatigue stress conditions. The tensile and fatigue fracture surfaces of the above-mentioned specimens were observed, and thisstudy attempted to investigate the tensile and fatigue deformation behavior of strip cast Al–5 wt.%Mg based on the fi ndings.

      • 다변량 분석법을 이용한 소양강댐 상류 유역의 하천 수질 평가

        최한규,백효선,허준영 江原大學校 産業技術硏究所 2002 産業技術硏究 Vol.22 No.A

        The object of this study is to evaluate the factors affecting the water quality and to propose the influence of dominant factor quantitatively. The correlation analysis was performed to know the correlationship among the water quality items. As a result of partial correlation analysis, it was shown that the water quality items are affected by the rainfall item directly. The factor analysis was performed to grasp some number of factors on each point for deducing the items of similar variable characteristics. The four points were divided into different factor groups. It was grasped that NH_3-N and NO_3-N items have different variable characteristics after comparing the items. The Multiple regression analysis can decrease the number of observation. In the deduced multiple regression formula, it was shown that the rate of T-N, NH_3-N and NO_3-N in the independent variable took about 60% among all the regression formulas.

      • KCI등재후보

        산불진화정보 관리를 위한 Mobile GIS 공간 데이터 압축기법 개발

        조명희,이명보,이시영,김준범,권봉겸,허영진 한국지리정보학회 2004 한국지리정보학회지 Vol.7 No.2

        최근 무선 인터넷 및 통신기술의 눈부신 발달과 LBS(location based service)개념을 기반으로 한 mobile GIS 기술 개발은 대규모 산불 발생시 정확한 현장 파악과 신속한 상황보고 뿐만 아니라 사고 예방과 분석·평가에 이르기까지 의사결정지원시스템으로 자리를 잡고 있다. 본 연구에서는 지상진화대의 정확한 위치와 이동상황을 실시간으로 파악하여 안전한 진화작업 유도 및 산불진화 환경정보를 제공을 목적으로 mobile GIS 기술 기반의 산불진화정보 관리시스템을 설계하고 네트워크 부하감소를 위하여 '.gci'라는 공간 데이터 압축기법을 개발하여 면, 선, 주기 데이터에 대하여 51~62%의 높은 압축률을 구현하였다. 따라서 대규모 산불 발생시 일어날 수 있는 안전사고를 미연에 방지하고 사고 발생시 신속한 후속조치로 안전하고 과학적인 산불진화 업무를 수행할 수 있도록 하였다. Recently GPS and mobile GIS technologies based on LBS (location based service) have played an important role as DSS (decision supporting system) for domestic forest fire extinguishment policies. In this study forest fire extinguishments information management system based on mobile GIS technique was designed to seize the exact location on wireless network so that it helps to guide the safe and efficient extinguishments affairs and provide the extinguishments environment toward ground fighting teams and the central forest government in real time. Moreover, possibly to operate this system, the foundation technologies by the name of `. gci such as the spatial data compression method, the spatial data transmission method over wireless network and the spatial analysis interface on PDA should be mainly considered. Especially, in this study the spatial data compression method having high compression rate from 51% to 62% for each polygon, line, and point data, without the loss of data was developed.

      • KCI등재
      • Fosfomycin의 항균효과 및 capillary electrophoresis에 의한 측정법에 관한 연구

        윤효인,박승춘,이규승,권진욱,조준형,신광순,김무열,허강준,조명행 충남대학교 수의과대학 동물의과학연구소 1996 動物醫科學硏究誌 Vol.4 No.-

        Fosfomycin, a low molecular antibiotic, is to be easily synthesized, therefore to be possibly used in veterinary sectors due to econimic reasons. In this study, we determined the antibacterial activities of fosfomycin against some domestic animal-origin pathogens, and its combined effects with some important antibacterials available. We also compared detection methods of fosfomycin from various measuring instruments. The results obtained through this experiment were as follows: 1. Antibacterial activities of fosfomycin against the pathogens used in this experiment were appeared fairly low. We found the antobacterial activities depanded on the kinds of media and the addition of some material thereins, which suggests the importance of appropriate medium so as to judge the antibacterial activity of fosfomycin. 2. Fosfomycin showed varying antibacterial effects in combination with other antibacterials, which should be taken into consideration when combining other antobacterials especially in the clinical settings. Of the combined antivacterials, fosfomycin had synergistic effects in combination with amoxicillin but antagonistic effects with oxytetracyline. 3. Conventional detection methods using HPLC, GC and spectrophotometer were not appropriate to measure fosfomycin. Capillary electrophoresis by the way of the indirect ultraviolet detection method was good enough to detect fosfomycin in the range of expected concentration in tissues, with the limit of quantitation (LOQ) of 1.25 ㎍/㎖. We recommend the eletrophoresis method could be used to detect fosfomycin, thereby being able to set the optimal dosage for animals and providing the measures in relation with the residual concentration in the meat.

      • The whole-exome sequencing in three families with atopic dermatitis

        ( Joon Hyuk Seo ),( Moo Yeol Hyun ),( Won Il Heo ),( Kapsok Li ),( Seong Joon Seo ),( Chang Kwun Hong ) 대한피부과학회 2015 대한피부과학회 학술발표대회집 Vol.67 No.2

        Background: The prevalence of atopic dermatitis (AD) has increased over a recent 10-year. AD tends to run in families that passed down from generation to generation and commonly starts in childhood. It is as high as 20% in children less than 5 years old. Thus, early discovery and therapy of AD are important. It has emerged the necessity of biomarker for early detection of AD. Objectives: The goal of this study is to find novel gene markers for diagnosis of early-onset atopic dermatitis in Koreans. Methods: Peripheral blood was obtained from three families (6 early-onset AD patients and 6 controls) with autosomal dominant condition. Whole Exome Sequencing (WES) was performed using SureSelect Human All Exon V4+UTR 71 Mb. Variants of atopic dermatitis were filtered step by step to gain the important candidate genes. Results: We have confirmed overlapping genes in common variants of filter 5 in three family. 15 genes were overlapped in filter 5 and two of them reached to filter 7 can be called “rare variant”. Uniquely, COL6A6 gene appeared in all of three family. We also found variants of filaggrin, filaggrin2 and IL4R that is well-known makers of atopic dermatitis. Conclusion: We were able to detect COL6A6 gene by finding overlapping genes in rare and common variants of three family. It may become a novel gene as early-onset AD marker.

      • SCISCIESCOPUS

        Robust plasmonic sensors based on hybrid nanostructures with facile tunability

        Heo, Chul-Joon,Jeon, Hwan Chul,Lee, Su Yeon,Jang, Se Gyu,Cho, Soojeong,Choi, Yeonho,Yang, Seung-Man The Royal Society of Chemistry 2012 Journal of materials chemistry Vol.22 No.28

        <P>Here, we demonstrate the preparation of a hybrid nanoplasmonic probe array, a nanoforest, which consists of gold nanostructures coated on top of silica nanospheres and evaporated gold film structure onto bottom through masks. Optically tunable plasmonic surfaces could be achieved by varying the nanoforest fabrication conditions, which acted as a selective nanoantenna. Plasmon coupling effects were effectively controlled by adjusting the vertical distance (nanogap) between the gold nanostructures on the silica bead and the bottom. Such control is critical to highly sensitive molecular detection applications. As a proof of concept, nanoforests were used as colorimetric sensors of refractive index changes. The sensors were highly sensitive and displayed distinct colors for small refractive index (RI) changes. The flexible and sensitive near/far-field optical properties render these nanoforests excellent plasmonic substrates for quantitative, sensitive and label-free sensing with nanoscale spatial resolution.</P> <P>Graphic Abstract</P><P>Nanoforests of Au-capped pillars were fabricated by colloidal lithography for robust plasmonic sensors with facile tunability. <IMG SRC='http://pubs.rsc.org/services/images/RSCpubs.ePlatform.Service.FreeContent.ImageService.svc/ImageService/image/GA?id=c2jm31958f'> </P>

      • Comparison of filtration performance of commercially available automotive cabin air filters against various airborne pollutants

        Heo, Ki Joon,Noh, Jung Woo,Lee, Byung Uk,Kim, Yeonsang,Jung, Jae Hee Elsevier 2019 Building and environment Vol.161 No.-

        <P><B>Abstract</B></P> <P>Controlling air pollutants in the automobile cabin environment has become increasingly important owing to the health risks of exposure to high concentrations of harmful air pollutants. To protect daily commuters and drivers against the harmful effects of air pollution, modern automobiles are commonly equipped with automotive cabin air filters (ACAFs). Thus, understanding the filtration performance of ACAFs is essential for assessing cabin indoor air quality. In this study, six original equipment manufacturer (OEM) and nine after-market ACAFs were selected and their particulate matter (PM) filtration performance against standard particle (ISO 12103-1 A2 dust), filter pressure drop under various airflow velocities, and gas removal performance against standard test gases (<I>n</I>-butane and toluene) were estimated. In the PM filtration test, the lowest filtration performance occurred at a particle size range of 0.3–0.5 μm, with a filtration efficiency of 50–90%, and the filtration performance increased with increasing particle size. The PM filtration performance of OEM ACAFs (72.3 ± 13.81%) was higher than that of after-market ACAFs (56.4 ± 23.72%). All test OEM ACAFs satisfied the Korea Air Cleaning Association standard filtration performance guidelines for 0.3–0.5-μm particles (>50%), but four of the nine after-market ACAFs did not satisfy the standard guidelines. In addition, only one of the six OEM ACAFs simultaneously satisfied the standard removal performance guidelines for <I>n</I>-butane (>70% after 1 min and >45% after 5 min) and toluene (>80% after 1 min and >70% after 5 min). This study provides valuable baseline information on ACAFs for understanding and improving cabin indoor air quality.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Commercial automotive cabin air filters (ACAFs) were evaluated and compared in terms of filtration and removal performance. </LI> <LI> Eleven of the 15 ACAFs tested satisfied the standard guidelines for PM filtration performance. </LI> <LI> Only one ACAF satisfied the standard guidelines for gas removal performance of both <I>n</I>-butane and toluene. </LI> <LI> The filtration performance of ACAFs varied depending on the type of filter (OEM or after-market filter). </LI> <LI> Careful selection of commercial ACAFs based on performance is essential to protect cabin indoor air quality. </LI> </UL> </P>

      • SCISCIESCOPUS

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼