http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
( Jia Cheng ),( Na Sun ),( Xin Zhao ),( Li Niu ),( Mei Qin Song ),( Yao Gui Sun ),( Jun Bing Jiang ),( Jian Hua Guo2 ),( Yuan Sheng Bai ),( Jun Ping He ),( Hong Quan Li ) 한국미생물 · 생명공학회 2013 Journal of microbiology and biotechnology Vol.23 No.8
Seventeen compounds derived from traditional Chinese medicines (TCMs) were tested for their antiviral activity against porcine reproductive and respiratory syndrome virus (PRRSV) in vitro. Visualization with the cytopathologic effect (CPE) assay and the 3-(4, 5-dimethyithiazol- 2-yl)-2,5-diphenyltetrazolium bromide test were used to determine the 50% cytotoxic concentration (CC50) and 50% effective concentration (EC50) in cultured Marc-145 cells. Among the tested compounds, chlorogenic acid and scutellarin showed potential anti-PRRSV activity. The EC50 values were 270.8 ± 14.6 μg/ml and 28.21 ± 26.0 μg/ml and the selectivity indexes were >5.54 and 35.5, respectively. The time-of-addition and virucidal assay indicated that the anti-PRRSV activity of the two compounds could be due to their inhibiting the early stage of virus replication and/or inactivating the virus directly. The inhibition of the virus attachment was not observed in the adsorption inhibition assay. The inhibition ratios of chlorogenic acid and scutellarin were, respectively, 90.8% and 61.1% at the maximum non-cytotoxic concentrations. The results have provided a basis for further exploration of their antiviral properties and mechanisms in vivo. We believe that the chlorogenic acid and scutellarin have a great potential to be developed as new anti-PRRSV drugs for clinical application.
Radiological gastrostomy: A comparative analysis of different image-guided methods
Hong-Tao Hu,Hang Yuan,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Hong-Tao Cheng,Jun-Li Ma,Yan Zhao,Li Jiang,Yu-Qing Zhao,Hai-Liang Li 소화기인터벤션의학회 2021 Gastrointestinal Intervention Vol.10 No.2
Background: Radiographic guided percutaneous gastrostomy has become a safe and effective enteral nutrition method for patients who can not eat by mouth. Fluoroscopy, computed tomography (CT) and cone-beam CT have been routinely used clinically. The aim of this study was to compare the advantages and disadvantages of percutaneous gastrostomy using different radiographic guided methods. Methods: We retrospectively analyzed the clinical data of 538 patients undergoing percutaneous gastrostomy in our department. According to the image guidance method used in gastrostomy, the patients were divided into groups A by fluoroscopy guidance, group B by fluoroscopy combined with C-arm CT guidance, and group C with the whole process CT guidance. The gastrostomy success rate, complication rate, procedure time, and patient radiation dose were analyzed in the three groups. Results: Among 538 patients, 534 were successful and the success rates are 94.3%, 99.3%, and 100% in group A, B, and C, respectively (P > 0.05). There were 3 cases occurred postoperative bleeding as serious adverse events and transferred to surgical gastrostomy. The minor complications include local infection, hyperplasia of granulation tissue, tube obstruction or prolapse, and local pain of the ostomy. The minor complication rates were 10.5%, 10.4%, and 7.7% in group A, B, and C, respectively (P > 0.05). The average procedure time was 25.57 ± 5.99 minutes, 29.01 ± 6.63 minutes, and 45.47 ± 8.98 minutes, respectively (χ2 = 87.98, P < 0.001). The average radiation dosage was 27.30 ± 19.27 mGy, 145.07 ± 106.08 mGy, and 2,590.26 ± 1,088.22 mGy, respectively (χ2 = 204.44, P < 0.001). Conclusion: There were no significant differences in the success rates and complication rates of gastrostomy under the three guiding methods. For difficult cases, CT-guided gastrostomy may be a very useful supplemental method.
Information Filtering for Time-delay Systems
Hong-Guo Zhao,Wei Wang 제어·로봇·시스템학회 2017 International Journal of Control, Automation, and Vol.15 No.1
This paper presents the information filter, which is developed in filtered forms, for time-delay systemswhich include continuous-time case and discrete-time case. By introducing delay-free observation, the optimalfiltering problems for time-delay systems can be converted into multiple steps prediction problems for delay-freesystems. Then, the recursive forms for optimal filter are given via innovation approach in Hilbert space. Furthermore,the information filter in Riccati recursions can be derived by using the matrix inversion Lemma to optimalfiltering formulas. Finally, the distributed Kalman filter for time-delay systems is designed based on informationfilter developed.
Optimal Filtering for Linear Discrete-Time Systems with Single Delayed Measurement
Hong-Guo Zhao,Huan-Shui Zhang,Cheng-Hui Zhang,Xin-Min Song 대한전기학회 2008 International Journal of Control, Automation, and Vol.6 No.3
This paper aims to present a polynomial approach to the steady-state optimal filtering for delayed systems. The design of the steady-state filter involves solving one polynomial equation and one spectral factorization. The key problem in this paper is the derivation of spectral factorization for systems with delayed measurement, which is more difficult than the standard systems without delays. To get the spectral factorization, we apply the reorganized innovation approach. The calculation of spectral factorization comes down to two Riccati equations with the same dimension as the original systems.
Spectral Factorization for Multiple Input Delayed Discrete-Time Systems with Applications to Control
Hong-Guo Zhao,Huan-Shui Zhang,Peng Cui,Xiao Lu 제어·로봇·시스템학회 2010 International Journal of Control, Automation, and Vol.8 No.3
This paper deals with the linear quadratic regulation problems for the linear discrete-time systems with input delays. The design of the optimal control law is transformed into solving one Diophantine equation and one spectral factorization with delays. A new and simple approach for the spectral factorization is proposed based on reorganized innovation analysis. The calculation of spectral factor comes down to solving Riccati equations with the same dimension as the original systems.
Radiological gastrostomy: A comparative analysis of different image-guided methods
Hong-Tao Hu,Hang Yuan,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Hong-Tao Cheng,Jun-Li Ma,Yan Zhao,Li Jiang,Yu-Qing Zhao,Hai-Liang Li 소화기인터벤션의학회 2021 International journal of gastrointestinal interven Vol.10 No.2
Background: Radiographic guided percutaneous gastrostomy has become a safe and effective enteral nutrition method for patients who can not eat by mouth. Fluoroscopy, computed tomography (CT) and cone-beam CT have been routinely used clinically. The aim of this study was to compare the advantages and disadvantages of percutaneous gastrostomy using different radiographic guided methods. Methods: We retrospectively analyzed the clinical data of 538 patients undergoing percutaneous gastrostomy in our department. According to the image guidance method used in gastrostomy, the patients were divided into groups A by fluoroscopy guidance, group B by fluoroscopy combined with C-arm CT guidance, and group C with the whole process CT guidance. The gastrostomy success rate, complication rate, procedure time, and patient radiation dose were analyzed in the three groups. Results: Among 538 patients, 534 were successful and the success rates are 94.3%, 99.3%, and 100% in group A, B, and C, respectively (P > 0.05). There were 3 cases occurred postoperative bleeding as serious adverse events and transferred to surgical gastrostomy. The minor complications include local infection, hyperplasia of granulation tissue, tube obstruction or prolapse, and local pain of the ostomy. The minor complication rates were 10.5%, 10.4%, and 7.7% in group A, B, and C, respectively (P > 0.05). The average procedure time was 25.57 ± 5.99 minutes, 29.01 ± 6.63 minutes, and 45.47 ± 8.98 minutes, respectively (χ2 = 87.98, P < 0.001). The average radiation dosage was 27.30 ± 19.27 mGy, 145.07 ± 106.08 mGy, and 2,590.26 ± 1,088.22 mGy, respectively (χ2 = 204.44, P < 0.001). Conclusion: There were no significant differences in the success rates and complication rates of gastrostomy under the three guiding methods. For difficult cases, CT-guided gastrostomy may be a very useful supplemental method.
Metastasis associated genomic aberrations in stage II rectal cancer
Hong Zhao,Zhi-Zhou Shi,Rui Jiang,Dong-Bing Zhao,Hai-Tao Zhou,Jian-Wei Liang,Xin-Yu Bi,Jian-Jun Zhao,Zhi-Yu Li,Jian-Guo Zhou,Zhen Huang,Ye-Fan Zhang,Jian Wang,Xin Xu,Yan Cai,Ming-Rong Wang,Yu Zhang 한국유전학회 2016 Genes & Genomics Vol.38 No.11
Genomic aberrations of rectal carcinoma, especially DNA copy number changes associated with metastasis were largely unclear. We aim to identify the metastasis associated biomarkers in stage II rectal cancer. Formalin-fixed, paraffin-embedded primary tumor tissues of stage II rectal carcinoma were analyzed by array-based comparative genomic hybridization, and genomic aberrations were identified by Genomic Workbench and SAM software. Copy number changes and mRNA expressions were validated by Real-time PCR in an independent rectal cancer samples. The results showed that the most frequent gains in stage II rectal cancer were at 1q21.2-q23.1, 3p21.31, 11q12.2-q23.3, 12q24.11-q24.31, 12q13.11-q14.1 and losses in 18q11.2-q23, 17q21.33-q22, 13q31.1-q31.3, 21q21.1-q21.3, 8p23.3-p23.1 and 4q22.1-q23. Twenty-two amplifications and five homozygous deletions were also identified. We further found that S100A1 (1q21.3-q23.1), MCM7 (7q22.1) and JUND (19p13.11) were amplified and overexpressed in stage II rectal cancer. Interestingly, the genomic aberrations affected 14 signaling pathways including VEGF signaling pathway and fatty acid metabolism. Most importantly, loss of 13q31.1-q34 and gain of 1q44 were associated with distant metastasis. Our results indicated that these metastasis associated genomic changes may be useful to reveal the pathogenesis of rectal cancer metastasis and identify candidate biomarkers.
A Coumarin-based Fluorescent Sensor for Selective Detection of Copper (II)
Jian-Hong Wang,Xin-Ling Guo,Xu-Feng Hou,Hui-Jun Zhao,Zhao-Yang Luo,Jin Zhao 대한화학회 2014 Bulletin of the Korean Chemical Society Vol.35 No.8
Cu (II) detection is of great importance owing to its significant function in various biological processes. In this report, we developed a novel coumarin-based chemosensor bearing the salicylaldimine unit (2) for Cu2+ selective detection. The results from fluorescence spectra demonstrated that the sensor could selectively recognize Cu2+ over other metal cations and the detection limit is as low as 0.2 μM. Moreover, the confocal fluorescence imaging in HepG2 cells illustrated its potential for biological applications.
Structural and Ferromagnetic Properties SnO2/TiO2 Nanotubes Obtained by Electrospinning
JIAN-GUO ZHAO,Yan-Hong Gu,Hong Jia,Zhuan Hu,Shuqian Qiao,Mengjing Jin,Panting Ge,WEI-YING ZHANG,Shijiang Liu,ZHAO-JUN LIU 성균관대학교(자연과학캠퍼스) 성균나노과학기술원 2017 NANO Vol.12 No.10
SnO2/TiO2 (Sn/Ti = 5/1) nanotubes were prepared by the electrospinning method. The morphology was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). The results showed that the inner diameter of prepared materials was about 100 nm and the wall thickness was about 10 nm. The results of X-ray diffraction (XRD) and high resolution transmission electron microscope (HRTEM) showed that SnO2/TiO2 nanotubes had a mixed phase of SnO2 rutile and TiO2 anatase structures and no impurity phases. The magnetic properties of the SnO2/TiO2 nanotubes were characterized by a superconducting quantum interferometer (SQUID). The results indicated that the samples exhibited room temperature ferromagnetism which may be attributed to the interface between TiO2 and SnO2 phases.
Wenhui Guo,Shuhu Guo,Xu Zhao,Zhenjun Yuan,Yu Zhao,Xin Chang,Hong Li,Xiong Zhao,Ye Wan,Dazhou Yan,Zhongyuan Ren,Xiaolei Fan,Xin Gao 한국공업화학회 2022 Journal of Industrial and Engineering Chemistry Vol.109 No.-
Ultra-high-purity (UHP) electronic-grade octamethylcyclotetrasiloxane (D4) is the key precursor of lowdielectricconstant (low-k) SiCOH films to manufacture integrated circuits (IC), meeting the stringentrequirements of the rapidly developing semiconductor industry. Commonly, metallic impurities in D4were removed by multiple unit operations of adsorption, filtration, and distillation, which could reducethe concentration of a single metallic impurity below 1 ppb. However, D4 with higher purity is requiredby semiconductor production due to an increase in transistor density. Herein, a novel method based onthe integrated simultaneous distillation–extraction (SDE) was developed for manufacturing UHPelectronic-grade D4. The lab and pilot scale experiments showed that the purity of water and D4 has apositive correlation. Based on the experimental data, a double-column process, consisting of azeotropic/extractive distillation column and precision distillation column with UNIQUAC method, was establishedto access the feasibility of scaling up the SDE process. According to the simulation results, D4with the purity > 99.999 wt.% and total metallic impurities (TMI) content below 1 ppb could be obtainedusing ultra-pure water.