RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 입원 환자 영양검색 전산 프로그램 개발

        안수미,윤기영,신연명,최경현,임근승,장문경,송윤미,공은희 고신대학교의과대학 2008 고신대학교 의과대학 학술지 Vol.23 No.2

        Background : About 30% of patients in the hospital are under nourishment. A large portion of people are undernourished when they are admitted to the hospital and in the majority of these, undernutrition develops further while in hospital. Patient-Generated subjective global assessment(PG-SGA), a method of nutritional assessment based on clinical judgment, has been widely used to assess the nutritional status of adults for both clinical and research purposes. Modified PG-SGA can be used as a nutrition screening tool, and a comprehensive nutrition assessment is desirable for those who are malnourished. The purpose of this study is to develop a simple, reliable and valid nutrition screening program(NSP). Methods : We applied the nutrition screening program(NSP) to adult inpatients who are at risk of malnutrition using the Modified Patient-Generated subjective global assessment(PG-SGA) and objective assessment(electrical medical record data). Results : Therefore simple and beneficial NSP is developed for patients with severe malnutrition. Using NSP. nutritional information of the severe malnutrition patient should be shared with the physicians and they should be taken care of by clinical dietitians to improve their nutritional status. Conclusion : The Modified PG-SGA and nutrition screening tool are simple, reliable and valid nutrition screening program(NSP).

      • KCI등재

        용융침투법으로 제조한 알루미나-유리 복합체의 동적 피로 특성 평가

        원대희,안승근,배태성,강동완,진영철 대한치과기재학회 1998 대한치과재료학회지 Vol.25 No.3

        The fatigue characteristics of alumina-glass composites were evaluated by biaxial flexure test under the dynamic loading conditions. 88 specimens were tested by tested by testing 22 samples at each of four loading rates : 0.01, 0.1, 1, and mm/min. A Vickers-produced indentation crack was made at the center of the tensile surface with load of 49.0 N, and the microstructural aspects of crack propagation was investigated under statically loaded state in distilled water at 37℃. The results obtained were summarized as follows; 1. The fatigue parameter of alumina-glass composite containing 6 mol % yttria was n=22.2, σf0=319.6 MPa. 2. 10-year failure stress of alumina-glass composite containing 6 mol% yttria was 171.7 MPa. 3. Fracture surface of alumina-glass composite indicated the frictional interlocking of jogs having the tendency of toughening by crack deflection, rather than by crack bridging.

      • KCI등재

        티타늄 레이저 용접부의 기계적 성질 평가

        이중재,김길수,안승근,배태성,박찬운 大韓齒科器材學會 2003 대한치과재료학회지 Vol.30 No.2

        This study was performed to examine the effects of laser output energy on the mechanical properties of laser-welded titanium joints. Titanium rods of 3 ㎜ in diameter were perpendicularly cut to 30 ㎜ in length for the laser welding. Two rods were fixed to each other with a jig and welded vertically using a Nd:YAG laser at output current of 210-270 A. The penetration depth of the laser beam against the titanium was measured with the changes of output current, pulse duration, and spot diameter. Mechanical tests included tensile testing and Vickers microhardness of the joints. Tensile testing was performed at the crosshead 00speed of 1.0 ㎜/min and a gauge length of 30 ㎜ with a universal testing machine. Vickers microhardness was mesured under 9.8 N load for 15 seconds. The results obtained were summarized as follows; With increasing the output current, the penetration depth of the laser to titanium was increased. Tensile strength values of laser-welded groups were the relatively higher than that of non-welded parent material group. There were significant differences in tensile strength between the specimens of laser-welded at output currents 250 A, 270 A and non-welded parent material group(p<0.05). Microhardness values were increased in the heat-affected zone. Brittle fracture regions were observed in the specimens of laser-welded at output currents 270 A.

      • KCI등재

        대한방사선종양학회지 게재 논문의 통계적 오류 현황

        박희철(Hee Chul Park),최두호(Doo Ho Choi),안성복(Song-Vogue Ahn),강진오(Jin Oh Kang),김은석(Eun-Seog Kim),박원(Won Park),안승도(Seung Do Ahn),양대식(Dae Sik Yang),윤형근(Hyong Geun Yun),정은지(Eun Ji Chung),지의규(Eui Kyu Chie),표홍렬( 대한방사선종양학회 2008 Radiation Oncology Journal Vol.26 No.4

        목 적: 본 연구는 대한방사선종양학회지 게재 논문의 통계 오류 현황을 파악하고 이에 근거한 문제 제기를 통해 학회지의 학술적 발전에 기여하고자 하였다. 대상 및 방법: 2006∼2007년 사이에 대한방사선종양학회지에 게재된 총 77편의 논문을 연구 대상으로 하였다. 각각의 논문에 적용된 통계 방법론의 적정성 평가는 통계점검표를 활용하였다. 통계점검표에는 연구의 종류, 통계기법의 사용 범위, 각 논문에 적용된 통계 기법의 종류, 통계적 기법 적용의 타당성 항목이 포함되었다. 통계 오류는 ‘생략의 잘못’과 ‘시행의 잘못’ 항목으로 나누었다. 한 논문에서 서로 다른 항목이 여러 가지 관찰된 경우 각각 횟수로 측정하였다. 같은 항목이 2회 이상 측정된 경우 1회로 횟수를 측정하였다. 통계 전문가가 개별 논문을 대상으로 통계점검표를 작성하였다. 일차 평가자가 방사선종양학 전문가가 아닌 것에서 올 수 있는 평가 오류가 있을 수 있으므로 개별 통계점검표는 간행위원회에서 한 차례 더 세부 점검을 하였다. 작성된 통계점검표의 통계 분석은 SAS (version 9.0, SAS Institute, NC, USA) 소프트웨어를 이용하였고 빈도분석을 시행하여 각 항목의 빈도와 백분율을 산출하였다. 결 과: 총 77편 중 원문을 다운로드 할 수 없었던 4편을 제외한 73편의 게재 논문을 대상으로 평가하였다. 증례보고는 5편, 원저 논문은 68편이었다. 대상 논문 중 46편의 논문에서 통계적 추론을 사용하였고, 16편의 논문에서 단순한 기술통계를 사용했으며, 11편의 논문에서는 통계적 기법을 사용하지 않았다. 추론통계를 사용한 46편의논문에서 사용된 추론통계의 횟수는 각각 분할표분석 17회(37.0%), 비교통계분석 23회(50.0%), 회귀분석 7회(15.2%), 상관분석 5회(10.9%), 생존분석이 27회(58.7%)였다. 통계 기법을 활용하여 연구 결과를 분석할 때 통계적용의 오류가 없는 논문은 19%였다. ‘생략의 잘못’은 34편(50.0%)의 논문에서 총 50회 관찰되었다. ‘시행의 잘못’은 35편(51.5%)의 논문에서 총 47회 관찰되었다. ‘생략의 잘못’과 ‘시행의 잘못’이 모두 발견된 논문은 21편 (30.9%)이었다.결 론: 대한방사선종양학회지에 게재된 논문에서 통계 분석 과정의 다양한 영역에 걸쳐 크고 작은 통계적 오류가 있음을 확인하였다. 향후 대한방사선종양학회지 투고 논문의 심사 과정에서 통계 오류에 관한 적절한 심사를 추가하는 것이 필요하다고 판단된다. Purpose: To improve the quality of the statistical analysis of papers published in the Journal of the Korean Society for Therapeutic Radiology and Oncology (JKOSTRO) by evaluating commonly encountered errors. Materials and Methods: Papers published in the JKOSTRO from January 2006 to December 2007 were reviewed for methodological and statistical validity using a modified version of Ahn’s checklist. A statistician reviewed individual papers and evaluated the list items in the checklist for each paper. To avoid the potential assessment error by the statistician who lacks expertise in the field of radiation oncology; the editorial board of the JKOSTRO reviewed each checklist for individual articles. A frequency analysis of the list items was performed using SAS (version 9.0, SAS Institute, NC, USA) software. Results: A total of 73 papers including 5 case reports and 68 original articles were reviewed. Inferential statistics was used in 46 papers. The most commonly adopted statistical methodology was a survival analysis (58.7%). Only 19% of papers were free of statistical errors. Errors of omission were encountered in 34 (50.0%) papers. Errors of commission were encountered in 35 (51.5%) papers. Twenty-one papers (30.9%) had both errors of omission and commission. Conclusion: A variety of statistical errors were encountered in papers published in the JKOSTRO. The current study suggests that a more thorough review of the statistical analysis is needed for manuscripts submitted in the JKOSTRO.

      • SCIESCOPUSKCI등재

        Nonsaponin fraction of Korean Red Ginseng attenuates cytokine production via inhibition of TLR4 expression

        Ahn, Huijeong,Han, Byung-Cheol,Kim, Jeongeun,Kang, Seung Goo,Kim, Pyeung-Hyeun,Jang, Kyoung Hwa,So, Seung Ho,Lee, Seung-Ho,Lee, Geun-Shik The Korean Society of Ginseng 2019 Journal of Ginseng Research Vol.43 No.2

        Background: Ginsenosides of Korean Red Ginseng extracts (RGE) and its saponin components suppress secretion of inflammasome-mediating cytokines, whereas the nonsaponin fraction (NS) of RGE oppositely stimulates cytokine secretion. Although direct exposure of NS to macrophages in mice induces cytokine production, oral administration of NS has not been studied in inflammasome-related disease in animal models. Methods: Mice were fed RGE or NS for 7 days and then developed peritonitis. Peritoneal cytokines were measured, and peritoneal exudate cells (PECs) were collected to assay expression levels of a set of toll-like receptors (TLRs) and cytokines in response to NS ingestion. In addition, the role of intestinal bacteria in NS-fed mice was assessed. The effect of preexposure to NS in bone marrow-derived macrophages (BMDMs) on cytokine production was further confirmed. Results: NS ingestion attenuated secretion of peritoneal cytokines resulting from peritonitis. In addition, the isolated PECs from NS-fed mice presented lower TLR transcription levels than PECs from control diet-fed mice. BMDMs treated with NS showed downregulation of TLR4 mRNA and protein expression, which was mediated by the $TLR4-MyD88-NF{\kappa}B$ signal pathway. BMDMs pretreated with NS produced less cytokines in response to TLR4 ligands. Conclusion: NS administration directly inhibits TLR4 expression in inflammatory cells such as macrophages, thereby reducing secretion of cytokines during peritonitis.

      • SCIESCOPUSKCI등재

        Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

        Seung-Geun Ahn,Jae-Min Seo 대한치과보철학회 2014 The Journal of Advanced Prosthodontics Vol.6 No.3

        Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

      • KCI등재

        COMPARISON OF MECHANICAL PROPERTIES OF VARIOUS POST AND CORE MATERIALS

        Ahn Seung-Geun,Sorensen John A. The Korean Academy of Prosthodonitics 2003 대한치과보철학회지 Vol.41 No.3

        Statement of problem: Many kinds of post and core systems are in the market, but there are no clear selection criteria for them. Purpose: The purpose of this study was to compare the flexural strength and modulus of elasticity of core materials, and measure the bending strength of post systems made of a variety of materials. Material and Methods: The flexural strength and elastic modulus of thirteen kinds core buildup materials were measured on beams of specimens of $2.0{\times}2.0{\times}24{\pm}0.1mm$. Ten specimens per group were fabricated and loaded on an lnstron testing machine at a crosshead speed of 0.25mm/min. A test span of 20 mm was used. The failure loads were recorded and flexural strength calculated with the measured dimensions. The elastic modulus was calculated from the slopes of the linear portions of the stress-stram graphs. Also nine kinds commercially available prefabricated posts made of various materials with similar nominal diameters, approximately 1.25mm, were loaded in a three-point bend test until plastic deformation or failure occurred. Ten posts per group were tested and the obtained data were anaylzed with analysis of variance and compared with the Tukey multiple comparison tests. Results: Clearfil Photo Core and Luxacore had flexural strengths approaching amalgam, but its modulus of elasticity was only about 15% of that of amalgam. The strengths of the glass ionomer and resin modified glass ionomer were very low. The heat pressed glass ceramic core had a high elastic modulus but a relatively low flexural strength approximating that of the lower strength composite resin core materials. The stainless steel, zirconia and carbon fiber post exhibited high bending strengths. The glass fiber posts displayed strengths that were approximately half of the higher strength posts. Conclusion: When moderate amounts of coronal tooth structure are to be replaced by a post and core on an anterior tooth, a prefabricated post and high strength, high elastic modulus core may be suitable. CLINICAL IMPLICATIONS In this study several newly introduced post and core systems demonstrated satisfactory physical properties. However when the higher stress situation exists with only a minimal ferrule extension remaining a cast post and core or zirconia post and pressed core are desirable.

      • Improvement of the Core Loss of SiFe by Optimizing the Operation Conditions of the Laser Scribing

        Ahn, Seung Joon,Park, Chul Geun,Lim, J.S.,Baik, K.H.,Kim, Dae Wook,Kim, Ho Seob,Ahn, Seung Joon Trans Tech Publications, Ltd. 2006 Materials science forum Vol.510 No.-

        <P>The magnetic domain refinement was carried out by laser pulse scribing in order to reduce the core loss of SiFe. The laser pulses were generated by a Q-switched Nd:YAG laser, and the optical frequencies of the laser pulses were altered by using the SHG and the THG. The core losses were measured and analyzed to find optimal parameters of the laser treatment. The laser beam was focused with a spot size of 0.2 mm, and pulse energy of 10~30 mJ and the lines were scribed with a period of ~5 mm. The core loss was improved up to 19 % with the THG of Q-switched Nd:YAG laser in 3% SiFe.</P>

      • KCI등재
      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼