http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
고강도 콘크리트에서 대구경 아령형 전단스터드의 내력 평가
심학보(Shim, Hak-Bo),정경수(Chung, Kyung-Soo),김원기(Kim, Won-Ki) 대한건축학회 2013 大韓建築學會論文集 : 構造系 Vol.29 No.4
Shear studs are commonly used to transfer longitudinal shear forces across steel-concrete interface in composite member design. A lot of push-out tests of shear studs embedded in normal and high strength concrete were conducted. But there is not study of shear stud considered resistance of horizontal load and bearing strength of concrete until now. In this paper, it was performed push-out tests of large double head shear stud embedded in high strength concrete.(double head stud means that head of stud was installed on the above and the lower part.) and the strength of shear stud was evaluated with bearing strength of concrete and resistance of horizontal load between concrete slabs. Experimental push-out tests were compared with theoretical calculation results.
沈鶴輔 충주대학교 1970 한국교통대학교 논문집 Vol.3 No.-
This investigation is carried out to obtain liquid chlorine and precipitate Sn with the electric-refining of crude SnCl₂ and SnCl₄. These crude matters are obtained from the treatment of byproducts which is resulted by the fused electric gilding of Sn.
α-cyanociannamic acid 의 加水分解에 對한 硏究
沈鶴輔 서울産業大學校 1975 논문집 Vol.8 No.1
The author has studied on the reaction of the hydrolysis of α-Cyanocinnamic acid(CCA)through nucleophilic addition of hydroxide ions and found that the hydrolysis of CCA is a homogeneous catalyzed system. When no catalyst is adopted, the reaction rate is proportional to the concentration of CCA but is proportional to ?? in the presence of catalysis of hydroxide ions. The evalued rate constants k₁and k₂are ?? mole??sec?? and ??, respectively.
심학보(Shim Hak-Bo),박순전(Park Soon-Joen),고주환(Ko Joo-Hwan) 대한건축학회 2011 大韓建築學會論文集 : 構造系 Vol.27 No.8
A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedded in high strength concrete is insufficient until today. So it is necessary to evaluate the load-slip behavior and the shear capacity of studs embedded in high strength concrete for the appropriate design code. In this paper, it was performed push-out tests of shear studs embedded in high strength concrete and fiber reinforced concrete used widely in high-rise building. Experimental push-out tests were used to evaluate both the shear stud capacity and the load-slip curve of the connector. And the results of the finite element model are compared with push-out tests and the values given in current codes of practice.
고강도콘크리트를 사용한 전단스터드의 푸쉬 아웃 성능 실험
심학보(Shim, Hak Bo),박순전(Park, Soon Joen),이주호(Lee, Joo-ho) 한국구조물진단유지관리학회 2009 한국구조물진단학회 학술발표회논문집 Vol.2009 No.2
A lot of push-out test results of studs in normal strength concrete have been presented. So present design methods in the codes for the calculation of the shear strength of studs are based on the test results of studs embedded in normal strength concrete. But knowledge of the load-slip behavior and the shear capacity of the stud in high strength concrete are limited to data obtained from the experimental push-off tests. So It is necessirary to evaluate the shear capacity of studs embedded in high strength concrete for the appropriate design code. Because it shows that the concrete compressive strength significantly affects the strength of the stud connections. In this paper, it was performed push-out test of shear studs in high strength concrete used in construction of high-rise building. Test results are compared with them calculated from current design codes.
H<SUP>∞</SUP> 제어알고리즘에 의한 AMD 시스템의 제진성능향상
심학보(Shim Hak-Bo),이헌재(Lee Heon-Jae),박순전(Park Soon-Jeon),김상대(Kim Sang-Dae) 대한건축학회 2008 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.28 No.1(구조계)
High rise buildings vibrate sensitively by the strong wind with reduction of weight and damping ratio recently. As increased the high rise buildings, a lot of people appeal the problems in serviceability caused by intensive vibration of building when strong wind has passed. In this paper, the active mass damper (AMD) which adopts the H∞ control algorithm is designed and applied to a exist building structure. This may be the first full-scale application of AMD to the existing building in the world. Two AMDs, which have 20 ton mass and 10 ton mass for x-axis and y-axis, respectively, are installed on the roof of the builidng structure, and those AMDs are design to control not only transverse response but also even torsion responses. In order to verify the performance of the AMD system, the controlled responses of the building structure are measured during a typhoon passes through the Korean Peninsula and compared with the uncontrolled responses obtained by a numerical simulation.
장경간 비정형 곡면 지붕층의 시공중 좌표 계측 사례 연구
심학보 ( Shim Hak-bo ),석원균 ( Seok Won-kyun ),박순전 ( Park Soon-jeon ) 한국건축시공학회 2019 한국건축시공학회 학술발표대회 논문집 Vol.19 No.2
In this paper, it was tried to prove the possibility and effect of coordinate measurement by using MEP layout equipment at the construction stage, and to propose a method to improve measurement accuracy during construction. For this study, the passenger terminal site, which is a long span structure, was selected and compared with three dimensional CAD drawings and construction measurement results using MEP layout equipment for the precise construction of long-span irregular curved roof layers. As a result, it was found that it is possible to construct three-dimensional curved roof layers using MEP layout equipment through measurement and analysis.
고강도콘크리트를 사용한 전단스터드의 푸쉬 아웃 성능실험
심학보 ( Shim Hak Bo ),박순전 ( Park Soon Joen ),이주호 ( Lee Joo-ho ) 한국구조물진단유지관리공학회 2009 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.13 No.2
A lot of push-out test results of studs in normal strength concrete have been presented. So present design methods in the codes for the calculation of the shear strength of studs are based on the test results of studs embedded in normal strength concrete. But knowledge of the load-slip behavior and the shear capacity of the stud in high strength concrete are limited to data obtained from the experimental push-off tests. So It is necessirary to evaluate the shear capacity of studs embedded in high strength concrete for the appropriate design code. Because it shows that the concrete compressive strength significantly affects the strength of the stud connections. In this paper, it was performed push-out test of shear studs in high strength concrete used in construction of high-rise building. Test results are compared with them calculated from current design codes.
현장 콘크리트 강도추정을 위한 초음파 속도법의 신뢰성에 관한 연구
심학보 ( Shim Hak-bo ),김용해 ( Jin Long-hai ),임홍철 ( Rhim Hong-chul ) 한국구조물진단유지관리공학회 2007 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.11 No.2
Ultra-sonic method are commonly used for concrete compressive strength test in a construction field, at present, various kinds of equation of strength are present, which have been used in a construction field, a strength test was carried out destructive test by means of core sampling. Non destructive test was conducted ultra-sonic method. The existing some equations for the estimate of compressive strength of concrete by non-destruction have some difference with measured data in this study. In this study, it is to suggested new equation for estimation of compressive strength to develop the application in our country's construction site.