http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Glucose 의 Rodox 반응에 의한 인슐린 방출 Device 의 설계와 합성
정동준,심정섭 ( Dong June Chung,Yoshihiro Ito,Yukio Imanishi,Jyong Sup Shim ) 한국공업화학회 1990 공업화학 Vol.1 No.2
New insulin-releasing system on the basis of the redox reaction of glucose was synthesized by immobilizing insulin through a disulfide bond(5, 5`-dithiobis(2-nitrobenzoic acid) to polymer membrane(poly(methyl methacrylate)) and enzyme(glucose oxidase). The disulfide bonds were cleaved upon oxidation of glucose with glucose dehydrogenase and glucose oxidase, releasing insulin from the membrane and enzyme. Sensitivity to glucose concentration was enhanced by coimmobilization of enzyme cofactors(nicotinamide adenin dinucleotide and flavin adenin dinucleotide) acting as electron mediator(for the membrane device), and further enhanced by direct immobilization of insulin on glucose oxidase(for the protein device). Both systems were specific to glucose, and the released insulin was indistinguishable from native insulin. The biological activity of released insulin was 81% of native insulin.
의치세정제와 소독제가 의치상 레진의 색조, 표면경도, 표면조도에 미치는 영향에 대한 연구
양희진,장복숙,정동준,허성주,한동후,심준성,장명우,Yang Hee-Jin,Jang Bok-Sook,Chung Dong-June,Heo Seong-Joo,Han Dong-Hoo,Shim June-Sung,Chang Myung-Woo 대한치과보철학회 2001 대한치과보철학회지 Vol.39 No.1
The purpose of this study is to compare effects of denture cleansers and disinfectants on the color. surface hardness, and surface roughness of reinforced acrylic resin using polyhedral oligosilsesquioxane molecules(POSS resin) to those of common resins. According to manufacturer's instructions, 45 specimens were made from three denture resins(Luciton 199, Paladent 20, POSS resin), and polished. Five denture cleansers(distilled water, glutaraldehyde, alkaline hypochlorites, chlorhexidine, alkaline peroxides) in combination with three denture resins were evaluated before and after immersion for 7 days. Color data in $L^*a^*b^*$ system were measured with a colorimeter. Surface hardness data were measured with a microhardness tester. Surface roughness data were measured with a 3-dimensional surface analyzer. Data were analyzed with two-way ANOVA, one-way ANOVA, and t-test. The results were as follows : 1. All resins(Luciton 199, Paladent 20, POSS resin) showed significant differences in color after immersion in hypochlorites(p<0.05). 2. POSS resin showed significant differences in color compared with Paladent 20 in all denture cleansers, but no statistically significant differences with Luciton 199(p<0.05). 3. Luciton 199 showed significant differences of surface hardness in chlorhexidine, Paladent 20 showed significant differences in glutaraldehyde and chlorhexidine. POSS resin showed a little change of surface in all denture cleanser, but no statistically significant differences(p<0.05). 4. Luciton 199 and Paladent 20 showed significant differences of surface roughness in hypochlorites and glutaraldehyde, and POSS resin showed no statistically significant differences in all denture cleansers(p<0.05).
표면 처리법에 따른 치과용 합금과 열중합형 레진 간의 결합 강도에 관한 연구
이주희,정은민,장복숙,정동준,허성주,한동후,심준성,Lee Joo-Hee,Jung Eun-Min,Jang Bok-Sook,Chung Dong-June,Heo Seong-Joo,Han Dong-Hoo,Shim June-Sung 대한치과보철학회 2002 대한치과보철학회지 Vol.40 No.4
The purpose of this study is to compare tensile bond strength between Cr-Co alloy and three denture base resins after surface treatment. Following the manufacturer's instructions, 180 bonded specimens were made from three denture base resins (Lucitone 199. Paladent 20. POSS resin) and three surface treatment methods (sandblasting. metal primer. silicoating) 20 samples were made in each group and a half was ther-mocycled 1000 times between $5^{\circ}C$ and $55^{\circ}C$. The tensile bond strength was measured using an Instron with 5mm/min crosshead speed. Data was analyzed with one-way ANOVA, T-test and Duncan test. The results were as follows : 1. Samples with metal primer coating had significantly high tensile bond strength than the other surface treated groups (p<.05). Significantly low tensile bond strength was shown in sand blasted groups (p<.05). 2. No significant difference was observed in metal primer coating groups before and after ther-mocycling (p>.05) 3. Tensile bond strength was decreased in silicoated samples after thermocycling (p<.05). 4. Of the surface treated groups with metal primer, Lucitone 199 had the greatest bond strength and POSS resin and Paladent 20 were followed (p<.05). 5. Of the surface treated groups with silicoating, POSS resin and Lucitone 199 had greater bond strength than Paladent 20 (p<.05).
폴리아스팔트아미드와 폴리(비닐 피롤리돈)의 상용블렌드 및 Semi-IPN 젤 제조
Fan Meng,전영실(Young Sil Jeon),정동준(Dong June Chung),김지흥(Ji Heung Kim) 한국고분자학회 2012 폴리머 Vol.36 No.5
폴리아스팔트아미드[α,β-poly(2-hydroxyethyl-DL-aspartamides), PHEAs]는 폴리아미노산의 일종으로서 잠재적인 의학 및 약학분야에 응용가능한 생분해성 생체적합성 재료로 널리 연구되어 왔다. 본 연구에서는 PHEA와 폴리(비닐 피롤리돈)(PNVP)의 블렌드 및 semi-IPN 젤에 관하여 다루었다. 블렌드 필름은 용액 캐스팅법으로 제조되었다. 제조된 블렌드는 전 조성에서 투명하였으며 DSC를 통해 조성에 따라 단조롭게 변화하는 단일한 유리전이 온도가 관찰됨으로써 두 개 고분자가 서로 상용성이 있음을 확인하였다. 고분자간의 가능한 수소결합 상호작용을 FTIR을 이용하여 설명하였다. 한편, 일정 조성의 PHEA/PNVP 블렌드 용액을 핵사메틸렌디이소시아네이트(HMDI)를 가교제로 사용하여 semi-IPN 타입의 하이브리드 젤을 제조하고, 제조된 젤의 팽윤 물성과 모폴로지를 조사하였다. PHEAs [α,β-poly(2-hydroxyethyl-DL-aspartamides)], a class of poly(amino acid), have been widely studied as biodegradable and biocompatible polymers for potential biomedical and pharmaceutical applications. In this study, we investigated a homogeneous blend of PHEA with poly(N-vinyl pyrrolidone) (PNVP) and its semi-IPN (semi-interpenetrating polymer network) gels. Blend films were prepared by a solution casting method. The resulting blends were totally transparent over the whole composition ranges and the single Tg, changing monotonously with composition, was observed by DSC to confirm the miscibility between these two polymers. FTIR was used to discuss the possible hydrogen-bonding interaction between polymers. In addition, semi-IPN type gels were prepared by chemical crosslinking of PHEA/PNVP blend solution using hexamethylene diisocyanate (HMDI) as a crosslinking reagent. The prepared gel was characterized by their swelling property and morphology.