RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        개인병사의 생존성 증대를 위한 생체신호 모니터링 기법의 설계 및 구현

        이승열,박상훈,이춘우,김현준,채제욱,Lee, Seung-Youl,Park, Sang-Hoon,Lee, Choon-Woo,Kim, Hyun-Jun,Chae, Jae-Wook 한국군사과학기술학회 2013 한국군사과학기술학회지 Vol.16 No.6

        Recently, personal health monitoring system using intelligent biosensors and equipments has been realized. This system can be adopted for soldier's biosignal monitoring system. In this paper, we propose a soldier biosignal monitoring system using personal biosensors, such as the ECG sensors and accelerometer.

      • KCI등재후보

        TACE의 중재적 시술시 환자의 피폭선량 평가

        이승열(Seung-Youl Lee),임현수(Hyun-Soo Lim),한만석(Man-Seok Han) 대한방사선과학회(구 대한방사선기술학회) 2011 방사선기술과학 Vol.34 No.3

        Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients’ thyroid and genital gland. The average of ED (effective dose) was 18.43±6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient. TACE의 중재적 시술시 환자와 시술자가 받는 피폭선량을 평가하고, 환자의 피폭선량을 최소화하기 위한 방안을 모색하기 위함이다. 2010년 6월부터 9월까지 중재적 시술의 빈도와 방사선 피폭의 양이 비교적 큰 TACE 시술환자를 대상으로 혈관조영장비(Philips Allura Xper FD 20)와 장비내 장착된 Ionization chamber에 의해 나타나는 DAP(Dose area product)값에 교정상수를 적용시켜 시술시 환자가 받는 유효선량을 근사적으로 얻어냈으며 환자와 시술자의 갑상선과 생식선 주위에 TLD를 부착하여 피폭선량을 산출하고 SPSS 통계에 의한 분석과 평가를 하였다. DAP값에 의해 산출된 TACE 시술시 1인당 ED(Effective Dose)는 평균 18.43±6.63 mSv로 나타났으며 이는 전국 평균값의 75%에 해당한다. 또한 TLD에 의해 측정된 환자의 갑상선과 생식선부위의 1인당 평균피폭 선량은 각각 0.37 mSv, 0.77 mSv로 나타났으며 보호용구를 착용한 시술자는 환자 1인당 각각 0.07 mSv, 0.01 mSv의 평균피폭선량을 받았다. 시술에 참여하는 모든 의료진들은 법적 선량한도의 적용을 받지 않는 방사선의료피폭에 대해 경각심을 가져야하며, 영상모니터에 실시간으로 표시되는 DAP값을 이용하여 환자의 피폭선량을 고려하며 시술에 임해야하며 시술에 방해가 되지 않는 한도 내에서 환자에게 차폐용구를 적절히 활용해야 한다.

      • KCI등재

        엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구

        이승열(Seung Youl Lee),김재량(Jae Ryang Kim),김은림(Eun Rim Kim),이준호(Jun ho Lee),이창형(Chang Hyung Lee),박창원(Chang Won Park) 대한방사선과학회(구 대한방사선기술학회) 2016 방사선기술과학 Vol.39 No.2

        최근 인구 고령화에 따른 골다공증 환자의 증가 및 의료기기 시장의 성장으로 인해 엑스선골밀도측정기 시장이 커지고 있으며, 이에 따른 의료기기 허가‧심사건수가 증가하고 있다. 의료기기 기술문서는 의료기기의 허가‧심사시 가장 기본이 되는 문서로 필수 제출 첨부자료 중 하나이다. 기술문서는 의료기기 관련 법령 및 고시에 그 근거를 두고 있으며, 의료기기 전반적인 항목을 기술해야하는 만큼 작성자의 전문성이 필요한 항목이다. 하지만 최근 부정확한 작성의 증가로 인한 심사자들의 업무부담이 증가되고 있어 민원 처리 효율이 저하되고 있다. 특히 엑스선골밀도측정기의 경우 식품의약품안전처 기준규격이 없어, 의료기기 제조/수입업체 등에서 시험항목을 설정하는데 많은 어려움을 겪고 있다. 따라서 본 연구에서는 개선된 제도가 반영된, 엑스선골밀도측정기 기술문서 작성 가이드라인 개발을 위해 첫째, 개선된 제도 운영에 대한 조사, 품목별 의료기기의 제도 적용에 따른 문서 작성 방법 검토, 기 허가된 품목에 대한 허가 및 기술문서 검토를 완료하였다. 둘째, 품목별 시장현황 조사, 적용 가능한 국내·외 규격을 조사·분석하여 품목별 국제조화된 안전성 및 성능평가 시험기준 및 방법을 도출하였다. 마지막으로, 산·연·관 전문가협의체 논의를 거쳐 기술문서 작성 가이드라인(안)을 최종 도출하였다. The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

      • 경건과 디아코니아

        이승열(Seung-Youl Lee) 혜암신학연구소 2021 신학과교회 Vol.15 No.-

        경건은 모든 그리스도인들의 삶에 있어서 그리스도인다운 삶을 나타내주는 대표적이며 용어라고 할 수 있다. 그리고 이는 하나님을 사랑하는 것을 대표하는 용어이다. 교회의 본질적인 사명은 하나님을 사랑하는 경건과 이웃을 사랑하는 디아코니아 이 둘이 핵심이다. 기독교의 역사는 경건의 역사이기도 하다. 경건은 영성이라는 단어로 시대를 따라서 변화해 왔다. 성경에 나타난 기본적인 영성의 정신이 있고 계시된 하나님의 말씀 속에 담겨진 뜻을 실천해야 할 사명과 책임을 가진 그리스도인들과 교회는 세상 속에서 하나님의 뜻에 따라 실천하며 살아야 하는 것이 기본이며 사명이다. 이러한 실천이 디아코니아로 나타나야 하는 것이다. 영성에 대한 역사적 과정을 고찰해 보았다. 신구약 성경에 있는 영성, 고대 기독교 교부들의 영성, 사막교부들의 영성, 초대교회 이단이었던 영지주의의 영성, 어거스틴의 영성, 탁발수도회의 영성, 중세시대의 영성과 디아코니아, 종교개혁시대의 영성과 디아코니아로 루터, 칼뱅의 영성과 디아코니아 사상과 삶, 이어서 경건주의운동에 있어서 아른트(Arndt), 스페너(Spener), 프랑케(Francke), 진젠도르프(Zinzendorf) 등의 생애와 신학사상에 나타난 경건의 영성과 디아코니아적 삶을 고찰해 보았다. 한국 기독교의 역사 속에 디아코니아 선교의 역사와 영향력은 대단하다. 그럼에도 불구하고 보수적 복음주의 경향 즉 근본주의적 성향이 강한 한국교회가 균형 있는 경건과 디아코니아를 실천하지 못하고 있는 점을 반성해야 하고 갱신되어야 한다. Piety or Holiness can be said to be a term representing the Christian life. This is also a term that represents the love of God. The essential mission of the church is reverence to love God and the diakonia to love the neighbors. The history of Christianity is also the history of Piety(holiness). Piety(Holiness) has been used as the word spirituality and has changed with the times. Christians and churches who have the basic spirit of spirituality shown in the Bible and who have the mission and responsibility to practice the will contained in the revealed Word of God are to live according to the will of God in the world. This practice should appear as diakonia. So, I have considered the historical process of spirituality. Spirituality in the Old and New Testament, spirituality of ancient Christian fathers, spirituality of the desert fathers, spirituality of Gnosticism, which was a heresy of the early church, spirituality of Augustine, spirituality of the Alders, spirituality and diakonia in the Middle Ages, spirituality and diakonia in the Reformation era. I also considered the Spirituality and Diakonia in the life and theology of Luther and Calvin, followed by the life of Arndt, Spener, Francke, Zinzendorf, etc. in the Pietist movement. The history and influence of the Diakonia mission in the history of Korean Christianity is significant. However, since Korean churches have a strong conservative evangelical tendency, which is a fundamental spectrum, and does not practice balanced piety(holiness) and diakonia, such status quo must be reflected and renewed.

      • KCI등재

        치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구

        이승열(Seung-Youl Lee),김재량(Jae-Ryang Kim),이준호(Jun-Ho Lee),박창원(Chang-Won Park) 대한방사선과학회(구 대한방사선기술학회) 2016 방사선기술과학 Vol.39 No.4

        최근 인구고령화로 인하여 치과진료 주요대상인 노인층의 검사가 꾸준히 증가하고 있다. 따라서 치과 진단 용 엑스선장치 시장도 꾸준히 성장하고 있으며, 동시에 치과용엑스선장치의 허가·심사건수도 증가하고 있다. 의료기기 기술문서는 의료기기의 허가·심사 시 필수로 요구되는 자료이며, 해당 의료기기의 전반적인 항목 을 기술해야 하는 만큼 작성자의 업무 이해도 및 전문성이 필요하다. 그러나 국내 의료기기 제조·수입 업체 대부분이 영세하여 의료기기 인·허가 관련 전문 인력의 확보가 쉽지 않아, 이로 인한 기술문서의 부정확한 작성이 증가하고 있다. 이에 따른 심사자의 민원 처리 지연과, 제품의 신속한 시장 진입의 어려움이 발생되고 있다. 특히 치과용구강외엑스선장치, 치과용구강내엑스선장치, 암형전산화단층엑스선촬영장치, 포터블엑스선 촬영장치(이하 치과용엑스선장치)는 식품의약품안전처 기준 규격이 최근에 제정되거나 부재한 품목으로, 의료 기기 제조·수입업체에서 시험항목 설정 시 많은 어려움을 겪고 있기에, 개선된 규격이 반영된 치과용엑스선 장치 가이드라인(안)을 개발하여 관련 업체 및 심사자에게 도움을 주고자 한다. 본 연구를 위하여 첫째, 기술 문서에 대한 개선된 제도 운영 조사 및 의료기기의 제도 적용에 따른 문서 작성 방법을 검토하였으며, 둘째, 품목별 시장현황을 조사하고, 국내·외 규격을 분석하였으며, 셋째, 기 허가된 제품의 기술문서를 분석하여 품목별 올바른 작성방법과 국제조화된 시험항목, 기준 및 방법을 도출하였다. 마지막으로, 산·연·관 전문가 협의체 회의를 통하여, 공정하고 전문성이 강화된 기술문서 작성 가이드라인(안)을 도출하였다. Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

      • KCI등재

        다양한 크기의 마이크로 채널 내에서 이동하는 세포의 가시화 및 이동 속도 측정

        이승열(Seung Youl Lee),김명준(Myung Jun Kim),채상민(Sang Min Chae),진송완(Songwan Jin) 한국가시화정보학회 2011 한국가시화정보학회지 Vol.9 No.1

        In this paper, we applied various microfluidic chambers to visualize cell migration and measured the migration velocity in microchannels. Migration speed of B16 cell in a large channel was similar with that of wound healing experiment. However, the speed decreased gradually as the cell move inside of the channel. It is expected that this phenomenon is due to the shortage of oxygen or nutrition, which are essential for cell growth. In the case of cell in the small channel whose size is smaller than the cell, its speed was slower than that in a larger channel.

      • KCI등재

        몬테카를로 시뮬레이션을 이용한국내 일반엑스선검사 진단참고수준의 유효선량 평가

        이승열(Seung-Youl Lee),성열훈(Youl-Hun Seoung) 한국방사선학회 2021 한국방사선학회 논문지 Vol.15 No.7

        본 연구에서는 국가에서 제공하는 일반엑스선검사의 진단참고수준 중 다빈도 검사에 대한 유효선량을 몬테카를로 시뮬레이션을 이용하여 평가하고자 하였다. 일반엑스선검사의 진단참고수준에 대한 유효선량 평가는 가장 다빈도로 검사되는 두부 전후면(Anterior-Posterior; AP), 흉부 후전면(Posterior-Anterior; PA), 흉부 측면(Lateral; LAT), 복부 AP, 골반 AP 등 총 5개의 검사 부위로 선정하였다. 몬테카를로 시뮬레이션에 사용되는 관전압과 관전류 등의 물리적 조건은 국내 조건의 대표성을 나타내기 위해 질병관리청의 자료를 사용하였다. 국내 의료방사선 피폭량 평가를 위해 사용된 인체 전산 팬텀은 한국인의 표준 체형을 대표할 수 있고 국제규격의 ICRP 103 기반으로 제작된 HDRK-Man 전산 인체팬텀을 몬테카를로 시뮬레이션에 적용하였다. 그 결과, 성인 남성을 기준으로 두부 AP의 진단참고수준에 해당되는 유효선량은 0.086 mSv, 흉부 PA는 0.05 mSv, 흉부 LAT는 0.354 mSv, 복부 AP는 0.548 mSv, 골반 AP는 0.451 mSv로 평가되었다. In this study, the effective dose for frequently general radiography among the diagnostic reference level (DRL) for examinations provided by the government in Korea was evaluated using the Monte Carlo N-Particle eXtended (MCNPX) simulation tool. We were selected to evaluate for a total of 5 examination sites which included head anterior-posterior, chest (posterior-anterior, lateral), abdomen anterior-posterior and pelvis anterior-posterior. Physical conditions such as tube voltage and tube current used in MCNPX simulation were used in domestic conditions of the Korea Disease Control and Prevention Agency (KDCA). To evaluate domestic medical radiation exposure, we used the HDRK-Man computerized human phantom manufactured based on the international standard ICRP 103 that was applied to the MCNPX simulation. The phantom could represent the standard body shape of Koreans. As a results, the effective dose corresponding to the DRL based on adult males of head anterior-posterior position was 0.086 mSv, chest posterior-anterior position was 0.05 mSv, chest lateral was 0.354 mSv, abdomen anterior-posterior position was 0.548 mSv, and pelvis anterior-posterior position was 0.451 mSv.

      • KCI등재후보

        CT 외래환자의 만족도 향상을 위한 업무개선 연구

        한만석(Man-Seok Han),이승열(Seung-Youl Lee),이명구(Myeong-Goo Lee),전민철(Min-Cheol Jeon),조재환(Jae-Hwan Cho),김태형(Tae-Hyung Kim) 대한방사선과학회(구 대한방사선기술학회) 2012 방사선기술과학 Vol.35 No.1

        국내병원 대부분의 CT검사실은 One Stop Services를 목표로 운영하여 예약환자는 물론이고 전처치가 준비된 외래환자의 경우 당일 CT검사를 수행하고 있다. 하지만 One Stop Service라는 목표에는 양적인 접근은 가능할지언정 지루한 대기시간, 직원의 불친절도 등에 의한 질적인 저하를 야기 시키게 되었고 환자와 보호자들의 민원을 발생시키는 등 검사에 대한 불만족으로 이어지기도 한다. 따라서 본 연구는 직원의 친절도 향상, CT검사에 대한 이해도 향상, CT검사실의 환경개선, 당일 CT검사 대기시간의 단축 등, CT검사를 받는 환자의 불편사항을 찾아 만족도 향상을 위한 방안을 도출하고자 한다. CT검사 외래환자 중 조영제를 투여하는 복부 CT검사 환자를 대상으로 하고 CT검사 외래환자의 만족도를 확인하기 위해 설문지를 사용하였으며 개선 활동 전인 48명, 개선 활동 후 41명, 총 89명의 설문지를 2011.4.1- 2011.9.30까지 조사 하였다. 조사 방법은 직원의 친절도, CT검사 이해도, 환경 만족도는 설문을 통해서 조사하고 당일 CT검사 대기시간은 의료정보 통계로 조사하였으며 SPSS V. 15.0 을 이용하여 분석하였다. 개선 전과 개선 후의 전반적인 만족도를 비교한 결과 CT검사실 이용절차의 편리성은 Mean(SD) 5.83±2.06에서 Mean(SD) 8.88±1.87로 52.32%, 직원의 친절도는 Mean(SD) 7.15±1.72에서 Mean(SD) 9.44±1.24로 32%, 환경만족도는 Mean(SD) 5.90±1.89에서 Mean(SD) 9.00±1.59로 52.54%, CT검사의 이해도는 Mean(SD) 5.94±1.83에서 Mean(SD) 9.05±1.70로 52.36%가 각각 상승하였다. 또한 대기시간은 평균 25.33분에서 21.04분으로 약 16.93% 단축시키는 큰 효과를 얻을 수 있었고 병원의 경쟁력 강화와 수익 증대에도 기여할 것으로 사료 된다. Nowadays, most of the hospital serves "one stop service" for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the wating time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

      • KCI등재

        진단용엑스선촬영장치의 간접 선량 계산법 개발

        김정수,김성환,전민철,주원하,정민규,김미정,이승열,이태희,성열훈,Kim, Jung-Su,Kim, Sung-Hwan,Jeon, Min-Cheol,Ju, Won-Ha,Jeong, Min-Gyu,Kim, Mi-Jeong,Lee, Seung-Youl,Lee, Tae-Hee,Seoung, Youl-Hun 대한방사선과학회 2018 방사선기술과학 Vol.41 No.6

        The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼