http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
실시간 미디어 전송의 종단간 성능 향상을 위한 혼성 모니터링 기법
박주원,김종원,Park Ju-Won,Kim JongWon 한국통신학회 2005 韓國通信學會論文誌 Vol.30 No.10B
As real-time media applications based on IP multicast networks spread widely, the end-to-end QoS (quality of service) provisioning for these applications have become very important. To guarantee the end-to-end QoS of multi-party media applications, it is essential to monitor the time-varying status of both network metrics (i.e., delay, jitter and loss) and system metrics (i.e., CPU and memory utilization). In this paper, targeting the multicast-enabled AG (Access Grid) group collaboration tool based on multi-Party real-time media services, a hybrid monitoring scheme that can monitor the status of both multicast network and node system is investigated. It combines active monitoring and passive monitoring approaches to measure multicast network. The active monitoring measures network-layer metrics (i.e., network condition) with probe packets while the passive monitoring checks application-layer metrics (i.e., user traffic condition by analyzing RTCP packets). In addition, it measures node system metrics from system API. By comparing these hybrid results, we attempt to pinpoint the causes of performance degradation and explore corresponding reactions to improve the end-to-end performance. The experimental results show that the proposed hybrid monitoring can provide useful information to coordinate the performance improvement of multi-party real-time media applications. 네트워크 및 종단 노드의 시스템에 걸친 제한된 자원을 활용하여 실현되는 영상/음성 전달 서비스를 위한 멀티미디어 응용 프로그램의 품질을 보장하기 위해서는 지연, 지터, 손실과 같은 전송 상태와 CPU, 메모리의 사용량과 같은 시스템의 상태를 동시에 관찰하는 것이 필요하다. 본 논문에서는 액세스그리드 (Access Grid) 경우와 같이 IP 멀티캐스트 상에 동작하는 RTP/RTCP에 기반한 실시간 미디어 응용 프로그램을 대상으로 동적/정적 모니터링 방식을 혼용하여 멀티캐스트 상태와 시스템 상태를 측정하는 혼성 모니터링 방식을 제안한다. 또한 종단간 전송 품질이 저하된 경우 제안한 모니터링 방식에서 측정된 결과를 비교/분석하여 품질 저하의 원인을 판단하고 원인에 적합한 대응방안을 연계하고i라 한다. 이 결과를 바탕으로 네트워크/시스템의 상태 변화에 적응적인 영상/음성 전송 서비스의 가능성을 타진하고 종단간 전송 품질 저하 방지를 위한 효과를 예상한다.
효율적인 모바일 시스템 전력공급을 위한 전압 모드 2-페이스 벅 변환기
박주원,전인호,노정진,Park, Ju-Won,Jun, In-Ho,Roh, Jeong-Jin 한국전기전자학회 2014 전기전자학회논문지 Vol.18 No.3
Recently, Importance of power management circuit technology is increased with the development of portable electric devices. This paper presents a high performance DC-DC buck converter for mobile applications. Especially, presented design have low ripple voltages and driving capability of large load current. A designed voltage mode 2-phase DC-DC converter is implemented in a $0.35{\mu}m$ CMOS process, and the overall size is $2.35{\times}2.35mm^2$. The peak efficiency is 91% with a 4MHz frequency and the maximum load current is 4A. 최근 휴대용 전자기기의 발달로 인해 전력관리회로 기술의 중요성이 증가하고 있다. 본 논문에서는 휴대기기를 위한 고성능 DC-DC 벅 변환기를 설계하였으며 특히 출력에서의 리플 전압을 작게 하고 수 A급의 대용량 출력전류의 안정적인 구동이 가능하도록 2-페이스 구조를 사용하여 설계하였다. 설계된 전압모드 2-페이스 벅 변환기는 $0.35{\mu}m$ CMOS 공정을 통하여 칩으로 제작되었고 전체 칩의 크기는 $2.35{\times}2.35mm^2$, 동작주파수는 4MHz, 최대 4A의 부하전류를 구동할 수 있으며 최대 변환효율은 91% 이다.
누적 폭로지수를 이용한 유기용제 폭로량과 의무실 이용간의 관계
박주원,이순영,장재연,이경종,정호근,Park, Ju-Won,Lee, Soon-Young,Jang, Jae-Yeon,Lee, Kyung-Jong,Jeong, Ho-Gun 대한예방의학회 1998 Journal of Preventive Medicine and Public Health Vol.31 No.3
This study was conducted in order to clarify the factors affecting the number of utilization to health center for the shipyard workers who have been work in exposed environment to solvent. At first the tendencies of the number of utilization to health conte. in accordance with cumulative exposure(CE), lifetime weighted average exposure(LWAE), one's place of duty, work contents, states of using safety apparatus, the degree of the knowledge on handling solvents, exposure year. 1). The increase in the cumulative exposure(CE) war significantly higher in the number of utilization to health center. The group with longer exposure year showed significantly higher number of utilization to health center(p<0.01). Considering the work contents such as power blasting, spray, mixing and touch-up, the group of touch-up showed higher number of utilization to health center and this difference was statistically significant(p<0.001). Those who were not using the safety apparatus, showed higher number of utilization to health center, which was statistically significant(p<0.05). The degree of the knowledge on handling the solvent had no relation with using health center. 2) The results conducted from this study by multiple regression analysis in clarifying the factors affecting the number of utilization to health center, CE, exposure year and using safety apparatus was significant factor in utilization of health center.
메탈 화이버 버너에서의 연소 특성 및 복사 효율에 관한 실험적 연구
박주원(Ju-Won Park),정태용(Tae-yong Chung),신동훈(Dong-hoon Shin) 한국연소학회 2006 한국연소학회지 Vol.11 No.1
Radiant burners are applicable to drying, preheating and curing in materials manufacturing processes. Radiation efficiency is one of the important performance criteria for these burners. The wide variation in reported radiation efficiencies are partly due to the differences in the measurement techniques. In the present work, water cooled radiant heat flux meter was used to measure radiant heat flux from a metal fiber mat burner. Non-contact type thermometer was also utilized to measure the surface temperature of the burner. Combustion gas was measured by gas analyzers. According to the thermal loads and stoichiometric ratios, radiant heat transfer ratio and combustion performance were discussed here in.
1ton/hr 산업보일러용 저 NOx 오일버너에서의 연소특성
박주원(Ju-Won Park),신명철(Myung-Chul Shin),김세원(Se-Won Kim),류태우(Tae-U Yu),양원(Won Yang),고영건(Young-Gun Ko) 한국연소학회 2008 KOSCOSYMPOSIUM논문집 Vol.- No.-
Experiments were performed to investigate the combustion characteristics of low NOx burner for 1ton/hr industrial boiler, through the inflame measurement and flue gas analysis. Main combustion characteristics are shape of flame, NOx and CO concentrations, and radical distributions. Variable nozzles were used for liquid fuel injection to find out the combustion characteristics as the fuel atomization, and CCD camera was used to capture the radical distributions of flame. Through the experiments, we can obtain such goals as the low NOx of below 150ppm, CO of near zero corrected at O2 4%.
2014~2016년 동안 경남지역 소규모 급수시설에 대한 건강 위해성 평가 연구
박주원(Ju-Won Park),손송이(Song-Ee Son),이후장(Hu-Jang Lee) 한국환경보건학회 2018 한국환경보건학회지 Vol.44 No.3
Objectives: This study was investigated the characteristics of small-scale water works (SWW) in Gyeongnam area and conduct a health risk assessment of water-quality inspection items unfitted for water-quality standards (WQS). Methods: The characteristics of SWW in Gyeongnam province were analyzed using the data of SWW in the last three years (2014~2016) published in National Waterworks Information System. In addition, the health risk assessment for inspection items unfitted for WQS was carried out in four steps: hazard identification, dose-response assessment, exposure assessment, and risk characterization. Results: The total number of SWW in Gyeongnam area was gradually decreased from 2014 to 2016. In addition, drinking water sources of SWW were in the order of ground water, valley water, spring water, surface water, and river-bed water. The number of points unfitted for WQS in SWW by year was 22, 45, and 18 in 2014, 2015, and 2016, respectively, and a total of 112 points were found to unfit for WQS in SWW during 2014?2016. The hazard quotient (HQ) for fluoride, nitrate nitrogen, boron in the unfitted points for WQS was more than 1.0, and the mean values f or turbidity and color in points unfitted for WQS were 2.38 nephelometric turbidity unit and 16.25 color unit, respectively. Conclusions: The HQ for fluorine, nitrate nitrogen and boron was more than 1.0 in points unfitted for WQS among SWW in Gyeongnam area, and the turbidity and the color degree exceeded WQS, which mean that there is a possibility of harmful impacts on the human health.
손 모양 인식시스템에서 성능 향상을 위한 특징 파라메터 추출
박주원(Ju-Won Park),김영탁(Young-Tak Kim),김수정(Soo-Jong Kim),탁한호(Han-Ho Tack),이상배(Sang-Bae Lee) 한국지능시스템학회 2004 한국지능시스템학회 학술발표 논문집 Vol.14 No.2
최근 몇 년 동안 사람들의 고유한 생리적인 특징을 이용한 생체 인식은 새로운 학문으로서 연구 및 개발이 활발하게 진행되고 있다. Hand-Geometry는 생체 인식의 확인 그러고 취득의 편리 때문에 식별 그리고 확인을 위하여 사용되고 있다. 그러므로, 본 논문은 이러한 특징을 가지는 손의 기하학적인 Hand-Geometry 인식 시스템을 제안하고자 한다. 해부학적인 관점에서, 인간의 손은 길이, 폭, 두께, 기하학적인 모양, 손바닥의 모양, 그러고 손가락들의 기하학적인 모양까지 특성으로 나타내어 질 수 있다. 그러나 특징 데이터 가운데 사용자의 Hand-Geometry의 특징에 따라 길이 데이터가 변하는 것을 실험적으로 발견하였다. 따라서 이와 같은 가변적인 길이 데이터를 안정화시키기 위하여 본 논문에서는 길이 데이터의 기준점을 손톱 아래 점으로 정하고, GA를 적용하여 보다 안정된 특징점을 추출하였다. 본 논문에서 제안한 Hand-Geometry 인식 시스템은 성인 20명의 개인에 대해 100개의 측정 데이터에 기인한 확인 결과를 제시한다. 인식 과정은 320×240의 이미지로 실험하였고 인식 과정의 결과는 95%의 적중률과 0.020의 FAR로 나타났다.