RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 커피활성탄에 의한 Cu (2) 의 흡착

        김학희,김명녀,임성환 한국공업화학회 1999 응용화학 Vol.3 No.1

        Activated carbons were successfully prepared from coffee waste by chemical activation with Phosphoric acid. Coffee waste was roasted at 300∼400℃. Carbonization was carried out at 750℃, 1hr. Chemical activation was carried out by using phosphoric acid as an activation agent at 700℃, 2hr. The concentration of Phosphoric acid was in the range of 30% ∼50%. N_2-BET surface area of activated coffee char prepared by chemical activation was measured as about 975∼1154㎡/g. Adsorption concentration of copper(II) by coffee activated carbon was found in the range of 340ppm∼238ppm. Structural change of pore surface was observed by Scanning Electron Microscopy(SEM).

      • 고추씨 활성탄에 의한 폐수종의 크롬 및 구리 흡착

        김학희,지주호 한국공업화학회 2002 응용화학 Vol.6 No.2

        Activated carbons were prepared from agricultural by-product by chemicalactivation with potassium hydrovide. Preparation process of roasting, carbonization,and chemical activation was conducted. Specific surface areas of activated carbonprepared by chemical activation were measured as 1,355∼2,266 m^2/g Removal ofchromium and copper in solution by activated carbon was successfully carried out.SEM photo-graphy was used to observe the morphological change before and afteradsorption

      • KCI등재후보

        토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교

        김학희,정승은,이배영,최병길,신경섭 대한자기공명의과학회 1997 Investigative Magnetic Resonance Imaging Vol.1 No.1

        목적: 횡격막 파열은 그 진단이 어렵고 지연되는 경우가 많으며, 진단이 늦어지면 유병율과 사망율이 높아지므로 조기진다는 매우 중요하다. 저자들은 최근 많이 이용되는 영상진단법인 나선형 CT와 자기공명영상, 그리고 초음파건사중 어떤 방법이 가장 예민하고 정확한 진단방법인지 동물실험 모델을 통하여 평가하고자 하였다. 대상 및 방법: 토끼에서 인위적으로 횡격막파열을 대, 중, 소로 만든 후 1일, 3일, 7일째 나선형 CT와 자기공명영상, 그리고 초음파검사를 동시에 시행하였다. 결과: 횡격막파열의 진단 민감도와 특이도는 초음파검사가 94.4%와 92.9%, 자기 공명영상이 54.0%와 85.75, 나선형 CT가 46.0%와 78.6%이었다. 횡격막 파열의 진단은 초음파검사, 자기공명영상, 나선형 CT순으로 정확하였으며 초음파 검사가 자기공명영상이나 나선형 CT보다 유의하게 우월하였고(P<0.05), 자기공명영상과 나선형 CT는 유의한 차이가 없었다. 초음파검사는 파열의 크기와 상관없이 횡격막파열의 구별이 용이하였고 자기공명영상과 나선형 CT는 파열의 크기가 클수록 횡격막파열의 구별이 용이하였으나 통계적으로 유의한 차이는 없었다(P>0.05). 수술후 1일에는 전예에서 늑막삼출액이나 혈흉을 동반하였다. 이때에는 초음파나 자기공명영상이 나선형 CT에 비해 우월하였다. 시간경과에 따랄 초음파검사와 자기공명영상은 진단율이 상대적으로 저하되었으나 통게적으로 유의한 차이는 없었다(P>0.05) 탈장을 동반한 경우에는 진단의 민감도가 자기공명영상, 나선형 CT, 초음파검사순으로 높았으며 초음파검사가 상대적으로 낮았다. 그러나 통계적으로 유의한 차이는 없었다(P>0.05). 결론: 초음파검사가 횡격막파열의 진단에 가장 유용한 것으로 밝혀졌으며, 이러한 결과는 앞으로 임상에 적용하여 검증되어야 할 필요가 있다고 생각된다. Purpose: Traumatic rupture of the diaphragm is not easy to diagnose and often delayed. Delayed diagnosis of diaphragmatic rupture accompanied by higher chances of strangulation of herniated viscera which may result in higher morbility and mortality. The purpose of this study was to evaluate diagnostic accuracy of spiral CT, MRI and US for the diagnosis of diaphragmatic rupture in an animal model. Materials and Methods: Small, medium, and large sized transabdominal diaphragmatic ruptures were surgically made in experimental rabbits and then followed up with spiral CT, MR!, and US at 1 day, 3 day, and 1 week after operation. Results: US was superior to MR! or spiral CT in diagnosis of diaphragmatic rupture(P(0.05). The sensitivity and specificity were 94.4% and 92.9% for US, 54.0% and 85.7% for MRI, and 46.0% and 78.6% for spiral CT, respectively. The size of laceration was not related to diagnostic sensitivity in US. Sensitivity of MRI and spiral CT increased as the size of laceration were larger, but no statistical significance was present(P>0.05). All experimental animals developed pleural effusion or hemothorax one day after operation. In acute phase, US and MRI were more sensitive than spiral CT in detecting diaphragmatic rupture. Spiral CT was more sensitive than US and MRI in delayed phase but without statistical significance(P>0.05). In the experimental rabbits with accompanying visceral hernia through the diaphragmatic defect, diagnostic accuracy was found equally high among three image modalities(P>0.05). Conclusion: This study indicates that US is the most accurate diagnostic method in detecting injury to the diaphragm in a rabbit model. The findings obtained in this experimental study can be applied to the diaphragmatic rupture of human being.

      • KCI등재

        결핵성 관절염의 전산화단층촬영 소견

        김학희 대한영상의학회 1992 대한영상의학회지 Vol.28 No.4

        The sparsity of publication concerning CT findings of tuberculous arthritis prompted authors to retrospectively evaluate 12 patients with tuberculous arthritis for characteristic CT findings. In each patient, the diagnosis of tuberculous arthritis was confirmed by surgery or biopsy. The CT examinations were evaluated by two radiologists retrospectively. Involved joints were the hip joint in seven patients, the sacroiliac joint in three parients, and the shoulder and ankle joint in one patient each. CT features included subchondral bony erision(12 patients), soft tissue mass in the joint space(nine), widenining of the joint space(eight), ipsilateral muscle atrophu(eight), thickening of the joint capsule(seven), intra-articular effusion(six), soft tissue abscess(five), and bony sclerosis(four). In seven patients with the duration of symptoms less than 1 year, thickening of joint capsule and intra-articular effusion were the predominent findings, while bony sclerosis, gross bone estruction, and soft tissue mass in joint space were seen in five patients with the duration of symptoms longer than 1 year. Our results indicate that CT is useful in the diagnosis of tuberculous arthritis by demonstrating characteristic pathologic changes of the joint space, soft tissue abnormality and bony involvement.

      • KCI등재
      • KCI등재

        실시간 객체 추적을 위한 제어기 설계

        김학희 한국일러스아트학회 2010 조형미디어학 Vol.13 No.4

        능동 카메라를 기반으로 움직임 영역을 추출하는 차영상을 구할 경우, 연속된 두 영상 간 카메라의 움직임 영역이 함께 포함되기 때문에 실제로 움직인 물체만을 추출해내는 것에 어려움이 있다. 또한 대용량의 데이터를 처리해야 하는 비전 시스템의 특성으로 인해 실시간 처리를 보장하는 것이 매우 어렵다. 따라서 본 논문에서는 빠른 처리 시간과 정확성을 가진 움직임 추출 기법을 찾기 위하여 대표적인 배경 보정 기법인 특징점 기반 배경 보정 기법과 위치 센서를 이용한 배경 보정 기법의 특성과 성능을 비교한다. 그리고 보다 빠른 처리 시간과 높은 신뢰성을 보장하는 것을 목표로 두 기법의 장점을 추출하여 응용한 기법을 적용한다. 영상 처리를 통해 검출된 물체의 위치는 차영상의 무게중심점으로 나타내며 그 좌표가 영상 평면의 중심점과 일치하도록 구동부의 DC모터를 제어한다. 이때 전체 시스템의 수학적 모델링을 구하고 그 특성에 맞는 제어기를 설계하여 추적 성능을 향상시키고자 한다. In the case of the tracking system with an active camera, it is very difficult to guarantee real-time processing due to the attribute of vision system which handles large amounts of data at once and has time delay to process. The reliability of the processed result is also badly influenced by the slow sampling time and uncertainty caused by the image processing. In this paper, we figure out dynamic characteristics of pixels reflected on the image plane and derive the mathematical model of the vision tracking system which includes the actuating part and the image processing part. Based on this model, we find a controller that stabilizes the system and enhances the tracking performance to track a target rapidly. The centroid is used as the position index of moving object and the DC motor in the actuating part is controlled to keep the identified centroid at the center point of the image plane.

      • SCOPUSKCI등재

        Spherocarb 와 Sucrose Char 에 대한 비표면적과 세공부피의 측정

        김학희,박상진 ( Hak Hee Kim,Sang Jin Park ) 한국공업화학회 1994 공업화학 Vol.5 No.1

        Spherocarb와 Sucrose Char에 의해 흡착된 질소가스의 양은 온도를 77K에서 184K까지 일정하게 유지시키면서, 상대적 압력의 함수로서 측정되었다. 다른 온도에서의 Isotherm은 흡착제를 일정한 온도에서 유지시키면서, 액화질소, iso-펜탄, n-펜탄, 에틸알코올과 iso-프로필 알코올의 Slush bath를 사용하여 얻어졌다. 이 연구의 목적은 BET와 D-R같은 흡착모델을 사용하여, 실험적 데이타를 분석함으로써, 비표면적과 세공부피에 대한 정보를 얻는데 있다. The amount of nitrogen gas adsorbed by Spherocarb and Sucrose Char was measured as a function of the relative pressure with temperature being kept constant at 77 to 184K. Isotherms at different temperatures were obtained by keeping the adsorbent at a constant temperature using liquid nitrogen, iso-pentane, n-pentane, ethyl alcohol, and isopropyl alcohol slush baths. The objective for this study is to provide information on the specific surface area and pore volume by analyzing the experimental data using adsorption models such as the Brunauer-Emmett-Teller and Dubinin-Radushkevich models.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼