http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
윤용식,이동주 한국공작기계학회 2004 한국생산제조학회지 Vol.13 No.2
A non-contact precision measurement system is a theodolite system, a laser tracker and a photogrammetry system. etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it, we performed the study for a measurement accuracy of theodolite system when the distance between two theodolites is changed lm to 5m We could know that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is ± 0.02 mm on theodolite distance 3~4 m.
성장과 운동수행능력 향상에 도움을 주는 식이조성물의 개발
윤승원,정은희,양동식,이홍석,윤유식 대한지역사회영양학회 2003 대한지역사회영양학회지 Vol.8 No.3
We developed a dietary supplement using natural herbs and nutrients for the growth and exercise performance improvement. It called JR-22 supplement containing distilled extracts of natural herbs to remove bitterness and the addition of Vitamin B1, B6, Ca and xylitol. We investigated on the effect of JR-22 supplementation on the maximal exercise performance, IGF-1 (insulin like growth factor-1) concentration and antioxidant activity in SD rat model. In result, JR-22 supplement group was better than control group about 10% in exercise performance test and increased about 63% of IGF-1 concentration in blood. In addition, the oxidative damage induced by exercise was reduced by JR- 22 supplementation. Therefore, we suggested that JR-22 supplementation enhanced effectively exercise performance and IGF-1 concentration and reduced to oxidative stress in muscles. Also, we analysed biochemical factors in blood for the safety of JR-22 supplement. We known that there is no change of blood lactic acid, ammonia, inorganic phosphorous ion and creatine kinase activity.
데오드라이트 시스템의 측정 정확도에 대한 연구(Ⅱ) : 기준자 측정 높이에 따른 측정 정확도 A Measurement Accuracy for a Height of Scale Bar
윤용식,이동주,정종길 한국공작기계학회 2004 한국생산제조학회지 Vol.13 No.4
A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.
결합재 페이스트 충전에 따른 포러스콘크리트의 물성에 관한 기초적 연구
윤상혁,양동일,정근호,김성식,이영도,정상진 대한건축학회 2003 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.23 No.1(구조계)
Although porous concrete is recently used as a pavement at a parking lot, a public squre and a bicycle road, we use without enough examining. Most the maintenance of quality for porous concrete is only dealt with strength and color tone. Also, there is not et enough fundamental data about dynamical properties for strength, rate of void and water permeability. Even when it is applied to at the scene, it is been a matter. Accordingly in this study analyzed influences through the dynamical properties, combination, and time to vibration. After the analyzation, they investigated peculiar dynamics which are strength of porous concrete, rate of void, and water permeability follow the rate of increase on an admixture making pozzolan reaction. This is purpose to improve capacity of the sidewalk permeable concrete and development of the economical technique for pavement.
임신 40주와 출산 후 6주에 있는 20대 임산부 보행의 역학적 특성 비교
윤희중,문동안,정남주,금명숙,이경식,유실,김영란,한윤수 한국운동역학회 2000 한국운동역학회지 Vol.10 No.1
본 연구는 임신 40주와 출산후 6주간에 있는 임산부의 보행 동작의 특정을 규명함으로써 이와 관련된 연구자들에게 기초자료를 제공하고자 실시하였다. 이를 위해 임신 4주에 있는 임산부를 대상으로 1차 실험을 실시하였으며 동일한 대상자를 출산후 6주에 2차로 실험하여 자료를 수집하였다. 디지타이징 시 오차를 최소화하고 인체관절점의 분별을 위해 21개의 반사마커를 부착하였다. 10m의 보행주로를 걷는 동안 두 대의 비디오카메라를 이용하여60Hz로 자료를 수집하였으며 동시에 100Hz 지면반력자료를 수집하였다.수집되어진 자료는 DLT 방법을 사용하여 분석하였으며 이의 분석에 Kwon3d 프로그램을 활용하였다. 분석결과 다음과 같은 결론을 얻었다. 1. 임신 40주와 출산 후 6주의 보행 시 지지시간과 스윙시간의 비율이 다르게 나타났으며 보폭과 보간, 활보장은 임신 40주에서 더 큰 값을 보였다. 상체 전경각 역시 임신 40주에서 더 큰 값을 보였다. 힙관절, 무릎관절, 발목관절각도는 S1이 출산후 6주에서 큰 값을 보인반면 S2는 출산전후에 큰 변화를 보이지 않다. 2. 상하지면반력의 경우 FP1과 FP2는 임신 40주보다는 출산 6주에서 큰값을 보였지만 FP3는 임신 40주에서 보다 큰값을 보이고 있었다. 전후지면반력의 경우 출산전과 후 모두 Fy2에서 보다 큰 값을 보이고 있었다. This Study was to investigate kinematical characteristic comparison of the gait pregnant 40weeks and after delivery 6weeks 20´s women and provide the basic data. To accomplish this study, in the first, carry out an experiment with the pregnant women in the pregnant 40weeks on the videotape, and than the second, make an experiment with the kinematic data. Kinematic data were filtered with a low-pass, fourth-order Butterworth filter with an effective cut off frequency of 6Hz. The conclusions were drawn as follows; 1. Floor contact Periods(stance and swing rate) were differed from before and after the delivery and a pregnant 40 weeks was greater than after delivery 6 weeks in the step, width, stride. Also, a pregnant 40 weeks was greater than after delivery 6 weeks in the front angular. And the other angular components were represented similar pattern. 2. In the vertical load, delivery 6 weeks was grater than a pregnant 40 weeks in the FP1(first peak) and FP2(valley). And FP3(second peak)was represent that a pregnant 40 weeks was greater than delivery 6 weeks. Also, in the horizontal shear, Fy2(progressional force)was greater than Fy1(breaking force) about time of the delivery.
윤복식,김동석 弘益大學校 科學技術硏究所 1994 科學技術硏究論文集 Vol.5 No.-
Life testing data has some peculiar features which can be utilized for proper statistical analysis. Among others it has the bathtub curve describing the change of the failure rate according to the elapsed time. In this paper, we review various efforts to get life distributions fitted for the bathtub-like failure rate function and propose simple and effective life distribution models based on piecewise Weibull failure rate function. Also, we introduce a simple method to estimate the failure rate of the censored life testing data. We can utilize the results in this paper to develop a comprehensive computational tool for reliability analysis.
윤용식,이동주 한국공작기계학회 2003 한국생산제조학회지 Vol.12 No.4
Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ±0.5mm or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.
윤용식,이동주,윤인진 한국공작기계학회 2005 한국생산제조학회지 Vol.14 No.2
The theodolite system consists of two theodolites, a scale bar and a target bar. A measurement accuracy of theodolite system is affected by a measurement distance of each equipment. This study was performed for measuring an accuracy when the distance from theodolite to scale bar was changed 2~6 m on two theodolites distance 3 m. The results showed that the measurement accuracy could be ±0.021 mm when the distance from theodolite to target was 2, 3 and 6 m. Specially, it was found that the maximum measurement accuracy was ±0.017mm on theodolite collimation distance 3m and the distance 4 m of the theodolite and scale bar.
데오도라이트를 이용한 위성체 얼라인먼트 측정에 관한 연구
윤용식,이동주 한국공작기계학회 2003 한국생산제조학회지 Vol.12 No.6
A measurement of spacecraft alignment is an important process of spacecraft assembly, integration and test because it is necessary that a ground station controls the precise positions of on-orbit spacecraft by using the alignment data of attitude orbit control sensors(AOCS) on spacecraft. In addition, accuracy of spacecraft alignment requirement is about 0.1°- 0.7°. The spacecraft alignment is measured by autocollimation of theodolite. This paper describes the measurement principle and method of spacecraft alignment. The result shows that all of the AOCS on the spacecraft are aligned within the tolerance quired through the alignment measurement.