RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Comparison of methods for library construction and short read annotation of shellfish viral metagenomes

        Hong‑Ying Wei,Sheng Huang,Jiang‑Yong Wang,Fang Gao,Jing‑Zhe Jiang 한국유전학회 2018 Genes & Genomics Vol.40 No.3

        The emergence and widespread use of high-throughput sequencing technologies have promoted metagenomic studies on environmental or animal samples. Library construction for metagenome sequencing and annotation of the produced sequence reads are important steps in such studies and influence the quality of metagenomic data. In this study, we collected some marine mollusk samples, such as Crassostrea hongkongensis, Chlamys farreri, and Ruditapes philippinarum, from coastal areas in South China. These samples were divided into two batches to compare two library construction methods for shellfish viral metagenome. Our analysis showed that reverse-transcribing RNA into cDNA and then amplifying it simultaneously with DNA by whole genome amplification (WGA) yielded a larger amount of DNA compared to using only WGA or WTA (whole transcriptome amplification). Moreover, higher quality libraries were obtained by agarose gel extraction rather than with AMPure bead size selection. However, the latter can also provide good results if combined with the adjustment of the filter parameters. This, together with its simplicity, makes it a viable alternative. Finally, we compared three annotation tools (BLAST, DIAMOND, and Taxonomer) and two reference databases (NCBI’s NR and Uniprot’s Uniref). Considering the limitations of computing resources and data transfer speed, we propose the use of DIAMOND with Uniref for annotating metagenomic short reads as its running speed can guarantee a good annotation rate. This study may serve as a useful reference for selecting methods for Shellfish viral metagenome library construction and read annotation.

      • KCI등재

        Identification of a Methyltransferase Encoded by Gene ste16 and Its Function in Ebosin Biosynthesis of Streptomyces sp. 139

        Hong-Guan Xie,Yong-Gang Bao,Li-ping Bai,Jun-Jie Shan,Rong Jiang,Yang Zhang,Lian-Hong Guo,Ren Zhang,Yuan Li 한국미생물학회 2009 The journal of microbiology Vol.47 No.2

        Streptomyces sp. 139 generates a novel exopolysaccharide (EPS) designated as Ebosin, which exerts an antagonistic effect on IL-1R in vitro and anti-rheumatic arthritis activity in vivo. A ste gene cluster for Ebosin biosynthesis consisting of 27 ORFs was previously identified in our laboratory. In this paper, ste16 was expressed in Escherichia coli BL21 and the recombinant protein was purified, which has the ability to catalyze the transfer of the methyl group from S-adenosylmethionine (AdoMet) to dTDP-4-keto-6-deoxy-D-glucos, which was thus identified as a methyltransferase. In order to determine the function of ste16 in Ebosin biosynthesis, the gene was disrupted with a double crossover via homologous recombination. The monosaccharide composition of EPS-m generated by the mutant strain Streptomyces sp. 139 (ste16-) was found to differ from that of Ebosin. The IL-1R antagonist activity of EPS-m was markedly lower than that of Ebosin. These experimental results have shown that the ste16 gene codes for a methyltransferase which is involved in Ebosin biosynthesis.

      • KCI등재

        Radiological gastrostomy: A comparative analysis of different image-guided methods

        Hong-Tao Hu,Hang Yuan,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Hong-Tao Cheng,Jun-Li Ma,Yan Zhao,Li Jiang,Yu-Qing Zhao,Hai-Liang Li 소화기인터벤션의학회 2021 Gastrointestinal Intervention Vol.10 No.2

        Background: Radiographic guided percutaneous gastrostomy has become a safe and effective enteral nutrition method for patients who can not eat by mouth. Fluoroscopy, computed tomography (CT) and cone-beam CT have been routinely used clinically. The aim of this study was to compare the advantages and disadvantages of percutaneous gastrostomy using different radiographic guided methods. Methods: We retrospectively analyzed the clinical data of 538 patients undergoing percutaneous gastrostomy in our department. According to the image guidance method used in gastrostomy, the patients were divided into groups A by fluoroscopy guidance, group B by fluoroscopy combined with C-arm CT guidance, and group C with the whole process CT guidance. The gastrostomy success rate, complication rate, procedure time, and patient radiation dose were analyzed in the three groups. Results: Among 538 patients, 534 were successful and the success rates are 94.3%, 99.3%, and 100% in group A, B, and C, respectively (P > 0.05). There were 3 cases occurred postoperative bleeding as serious adverse events and transferred to surgical gastrostomy. The minor complications include local infection, hyperplasia of granulation tissue, tube obstruction or prolapse, and local pain of the ostomy. The minor complication rates were 10.5%, 10.4%, and 7.7% in group A, B, and C, respectively (P > 0.05). The average procedure time was 25.57 ± 5.99 minutes, 29.01 ± 6.63 minutes, and 45.47 ± 8.98 minutes, respectively (χ2 = 87.98, P < 0.001). The average radiation dosage was 27.30 ± 19.27 mGy, 145.07 ± 106.08 mGy, and 2,590.26 ± 1,088.22 mGy, respectively (χ2 = 204.44, P < 0.001). Conclusion: There were no significant differences in the success rates and complication rates of gastrostomy under the three guiding methods. For difficult cases, CT-guided gastrostomy may be a very useful supplemental method.

      • KCI등재

        Feedback in Interpreter Training

        Hong Jiang 한국통역번역학회 2011 통역과 번역 Vol.13 No.1

        Interpreting is a complex skill, involving many sub-skills. For students to acquire the skills and develop from a novice to a journeyman, feedback is one important component of the training process. This presentation hopes to explore the relationship of feedback and skill development, the various forms of feedback and how they can be effectively used to contribute to students’ learning process.

      • Detection and Prognostic Analysis of Serum Protein Expression in Esophageal Squamous Cell Cancer

        Jiang, Hong,Wang, Xiao-Hong,Yu, Xin-Min,Zheng, Zhi-Guo Asian Pacific Journal of Cancer Prevention 2012 Asian Pacific journal of cancer prevention Vol.13 No.4

        Objective: To assess differences in serum proteins in esophageal squamous cell carcinoma patients. Methods: 144 esophageal squamous cell carcinoma patients and 50 healthy volunteers were included in this study, with surface-enhanced laser desorption-ionization time-of-flight mass spectrometry and weak cation exchange magnetic beads. Follow-up allowed the relations between serum proteins and prognosis to be analyzed. Results: A total of 93 protein peaks were detected (molecular weight range: 1500-30000), 10 demonstrating statistically significant differences. There were no differences in protein peaks between 92 patients with a survival more than 2 years and 52 patients with survival less than 2 years. There were two significantly different protein peaks between 45 stage II patients with a survival more than 2 years and 14 stage II patients with survival less than 2 years. There was one significantly different protein peak between 22 stage III patients with a survival more than 2 years and 29 stage III patients with survival less than 2 years. Conclusion: Differences of serum proteins in esophageal squamous cell carcinoma are related to prognosis of patients. The protein fingerprint can be helpful for clinical diagnosis and treatment.

      • KCI등재

        A flow rate on-line monitoring method for piezoelectric pump based on self-sensing circuit

        Hong Jiang,Guohui Wu,Lipeng He,Yuecheng Wang,Dianbin Hu,Zheng Zhang,Guangming Cheng 대한기계학회 2022 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.36 No.5

        This paper presents a new flow rate monitoring method for a piezoelectric micropump based on a self-sensing circuit. Utilizing the voltage generated by the secondary direct piezoelectric effect as the sensing voltage, a soft sensor of the piezoelectric actuator can be implemented onto the piezoelectric micropump. A bridge-type circuit is proposed as the selfsensing circuit, the piezoelectric micropump is fabricated with a circular piezoelectric actuator, the characteristics of the self-sensing voltage and the flow rate are experimentally investigated under different excitation voltages and frequencies. The results show that the method can accurately determine optimal frequency of the micropump (100 Hz, 280 Hz), and for a fixed frequency of 100 Hz and a voltage range of 50-180 V, the correlation between the self-sensing voltage and the flow rate is 0.9732. As a result, the method demonstrated in this paper allows precise monitoring of the flow rate of the piezoelectric micropump without using external sensors.

      • KCI등재

        A review on colorless and optically transparent polyimide films: Chemistry, process and engineering applications

        Hong-jiang Ni,Jin-gang Liu,Zhen-he Wang,Shi-yong Yang 한국공업화학회 2015 Journal of Industrial and Engineering Chemistry Vol.28 No.-

        Recent research and development of colorless and optically transparent polyimide (CPI) films have beenreviewed. CPI films possess both of the merits of conventional aromatic PI films and common polymeroptical film; thus have been widely investigated as components for microelectronic and optoelectronicfabrications. The current review coveres the latest research and development for CPI films, includingsynthesis chemistry, manufacturing process, and engineering applications. Especially, this reviewfocuses on the applications of CPI films as flexible substrates for optoelectrical devices, such as flexibleactive matrix organic light emitting display devices (AMOLEDs), flexible printing circuit boards (FPCBs),and flexible solar cells.

      • KCI등재

        Radiological gastrostomy: A comparative analysis of different image-guided methods

        Hong-Tao Hu,Hang Yuan,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Hong-Tao Cheng,Jun-Li Ma,Yan Zhao,Li Jiang,Yu-Qing Zhao,Hai-Liang Li 소화기인터벤션의학회 2021 International journal of gastrointestinal interven Vol.10 No.2

        Background: Radiographic guided percutaneous gastrostomy has become a safe and effective enteral nutrition method for patients who can not eat by mouth. Fluoroscopy, computed tomography (CT) and cone-beam CT have been routinely used clinically. The aim of this study was to compare the advantages and disadvantages of percutaneous gastrostomy using different radiographic guided methods. Methods: We retrospectively analyzed the clinical data of 538 patients undergoing percutaneous gastrostomy in our department. According to the image guidance method used in gastrostomy, the patients were divided into groups A by fluoroscopy guidance, group B by fluoroscopy combined with C-arm CT guidance, and group C with the whole process CT guidance. The gastrostomy success rate, complication rate, procedure time, and patient radiation dose were analyzed in the three groups. Results: Among 538 patients, 534 were successful and the success rates are 94.3%, 99.3%, and 100% in group A, B, and C, respectively (P > 0.05). There were 3 cases occurred postoperative bleeding as serious adverse events and transferred to surgical gastrostomy. The minor complications include local infection, hyperplasia of granulation tissue, tube obstruction or prolapse, and local pain of the ostomy. The minor complication rates were 10.5%, 10.4%, and 7.7% in group A, B, and C, respectively (P > 0.05). The average procedure time was 25.57 ± 5.99 minutes, 29.01 ± 6.63 minutes, and 45.47 ± 8.98 minutes, respectively (χ2 = 87.98, P < 0.001). The average radiation dosage was 27.30 ± 19.27 mGy, 145.07 ± 106.08 mGy, and 2,590.26 ± 1,088.22 mGy, respectively (χ2 = 204.44, P < 0.001). Conclusion: There were no significant differences in the success rates and complication rates of gastrostomy under the three guiding methods. For difficult cases, CT-guided gastrostomy may be a very useful supplemental method.

      • SCIESCOPUSKCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼