http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
내반슬로 인한 대퇴경골각의 변화가 골반경사각에 미치는 영향
김경석,류지미,김고운,김귀현,정원석,이종수,Kim, Kyoung-Seok,Ryu, Ji-Mi,Kim, Koh-Woon,Kim, Gwi-Hyun,Jeong, Won-Seok,Lee, Jong-Soo 척추신경추나의학회 2009 척추신경추나의학회지 Vol.4 No.2
Objectives : The purpose of this study was to investigate the Correlation between Pelvic angle and the Tibiofemoral angle in the Genu varum. Method : Age of All subjects were 20-37 years. 33(male 10, female 23) subjects were assessed by whole spine x-ray and orthogram. The collected data consisted of items on general characteristics, Pelvic Incidence(PI), Pelvic Tilt(PT), Sacral Slope(SS) and Tibiofemoral Angle(TFA) of the subjects. Results : The PI, PT and TFA had a relationship significantly. However, there was no relationship between SS and TFA. Conclusion : The results suggest that TFA is related to PI, PT. Internal rotation due to genu varum of femoral at hip influence that PI and PT increase.
김경석,김영훈,한정인,최광남,곽성관,김동식,정관수,Kim, K.S.,Kim, Y.H.,Han, J.-In,Choi, K.N.,Kwak, S.K.,Kim, D.S.,Chung, K.S. The Korean Vacuum Society 2008 Applied Science and Convergence Technology Vol.17 No.5
본 논문은 TIPS Pentacene을 유기반도체로 사용한 유기박막 트랜지스터의 용제에 따른 전기적 특성에 대한 연구로서, 용제로는 chlorobenzene, p-xylene, chloroform, toluene을 사용하였으며, 회전 도포 방법을 사용하여 TIPS pentacene을 혼합하여 적층하였다. chlorobenzene을 사용하여 만들어진 유기박막 트랜지스터는 $1.0{\times}10^{-2}cm^2/V{\cdot}s$의 전계효과 이동도, $4.3{\times}10^3$의 on/off 비율, 5.5 V의 문턱전압의 특성을 보였다. 반대로, chloroform을 사용하여 만들어진 유기박막 트랜지스터는 $5.8{\times}10^{-7}cm^2/V{\cdot}s$의 전계효과 이동도, $1.1{\times}10^2$의 on/off 비율, 1.7 V의 문턱전압의 특성을 보였다. 또한 각 용제에 따른 TIPS pentacene 결정크기를 AFM을 통하여 측정하였다. 이와 같은 결과들을 통하여, 더 높은 끊는점을 가진 용제는 TIPS Pentacene의 더 큰 결정 크기와 높은 결정화 성향으로 인하여 더 좋은 전기적 특성을 가지는 것을 확인할 수 있었으며, 본 실험에서는 끓는점이 가장 높은 chlorobenzene을 사용한 TIPS Pentacene 유기박막 트랜지스터가 가장 좋은 전기적 특성을 나타내는 것을 확인하였다. In this paper, we investigated the electrical properties of triisopropylsilyl (TIPS) pentacene organic thin-film transistor (OTFT) depending on solvent type. We spin coated TIPS pentacene by using chlorobenzene, p-xylene, chloroform, and toluene as solvents. Fabricated OTFT with chlorobenzene shows field-effect mobility of $1.0{\times}10^{-2}cm^2/V{\cdot}s$, on/off ratio of $4.3{\times}10^3$ and threshold voltage of 5.5 V. In contrast, with chloroform, the mobility is $5.8{\times}10^{-7}cm^2/V{\cdot}s$, on/off ratio of $1.1{\times}10^2$ and threshold voltage of 1.7 V. Moreover we measured the grain size of each TIPS pentacene solvent by atomic force microscopy (AFM). From these results, it can be concluded that a solvent with higher boiling point results in better electrical characteristics due to large grain size and high crystallinity of TIPS pentacene layer. In this paper TIPS pentacene with chlorobenzene shows the best electrical properties.
Ti 함량 변화에 따른 X선 노광 마스크용 W-Ti 흡수체의 물성 연구
김경석,이규한,임승택,이승윤,안진호,Kim, Gyeong-Seok,Lee, Gyu-Han,Im, Seung-Taek,Lee, Seung-Yun,An, Jin-Ho 한국재료학회 2000 한국재료학회지 Vol.10 No.3
W에 소량의 Ti를 첨가하여 그 함량 변화에 따른 X-선 마스크 흡수체용 W-Ti 박막의 물성을 연구하였다. W-Ti 박막은 DC magnetron sputtering system을 이용하여 증착하였다. Sputtering 증착시 증착압력의 증가에 따라 박막의 밀도는 감소하였으며 박막의 응력은 압축응력으로 바뀌었다. Ti 함량이 증가함에 따라 천이 압력 근방에서의 응력곡선의 기울기가 감소하였으며 천이 압력도 점차 낮아지는 경향을 보였다. Pure-W 시편의 경우 천이 압력이 약 6.5mTorr로 비교적 높았으며, 이 때 박막의 밀도는 $17.8g/\textrm{cm}^3$이었고 함량 6.5%에서 가장 낮은 천이 압력(4.3mTorr)을 보였으며, 이때의 박막 밀도는 $17.7g/\textrm{cm}^3$로 pure-W과 거의 차이가 없음을 알 수 있었다. SEM을 이용한 미세구조 분석결과 pure-W 박막은 원형의 주상정 조직을 보이고 있으며, Ti가 첨가된 W-Ti 박막의 경우에는 가늘고 긴 침상 모양을 가지는 주상정 조직을 형성하고 있다. 또한 이러한 침상조직은 Ti함량이 증가할수록 더욱 발달하고 있으며, AFM 분석결과 Ti 첨가 시편 모두 $18{\AA}$이하의 우수한 평균 표면 평활도를 나타내었다. 나타내었다. W-Ti film properties for X-ray absorber applications have been investigated with Ti composition have been investigated with Ti composition variation. W-Ti films were deposited by DC magnetron sputtering system. As the working pressure increases, film density decreases and film stress changes from compressive to tensile. The transition pressure (where the film stress in zero) and the stress gradient decrease by adding Ti into W-Ti(6.5 at.%) film shows the smallest stress gradient and transition pressure. It also shows high density ($17.7g/\textrm{cm}^3$) similar to that of pure-W ($17.8g/\textrm{cm}^3$) at the transition pressure. All the films show columnar structure, and its size decreases with increasing Ti composition. Surface roughness and thermal stability are improved by Ti-addition, resulting in a better property for X-ray absorber applications.
김경석,이상룡,김재훈,권도익,Kim, Kyung-sok,Lee, Sang-yong,Kim, Jae-hoon,Kwon, Do-ick 사상체질의학회 2001 사상체질의학회지 Vol.13 No.3
The irritable bowel syndrome(IBS) is the most common gastrointestinal disorder in clinical practice and is characterized by abdominal pain associated with a chronic disturbance of defecation. It is important to discriminate IBS from organic bowel disease. Based on clinical and epidemiologic studies, specific symptom criteria for IBS have been developed. The subject is a 29 year old man who has abdominal pain, chronic diarrhea, general weakness, dizziness, insomnia and has been diagnosed as irritable bowel syndrome. We classified this as Shaoyangin Mangyin(少陽人 亡陰證) and prescribed Hyeongbangjiwhangtang(荊防地黃湯) in accordance with the principle of pyoeumganggi(表陰降氣). In the result, we had the improvement of his symptoms.
ESPI를 이용한 자외선조사량에 따른 폴리머애자의 탄성계수 변화 연구
김경석,김동수,장호섭,박찬주,장완식,정현철,Kim, Kyeong-Suk,Kim, Dong-Soo,Chang, Ho-Sub,Pack, Chan-Joo,Jang, Wan-Sik,Jung, Hyun-Chul 한국생산제조학회 2010 한국생산제조학회지 Vol.25 No.6
Recently, environment problems have effects on the electronic equipments. Security problems are presented. For security reasons, it is necessary to study electronic equipments. In this paper, we handle the Elasticity modulus on the polymer insulator by UV irradiation. The types of material are used in this experiment, is the EPDM (Ethylene Propylene Diene Monomer). For increasing the reliability, real material specimens are used. For this study, we used ESPI (Electronic speckle pattern interferometry), UTM (Universal thesting machine) device, Accelerated weathering tester. Through this measurement, we evaluated how much UV irradiation has effect on polymer insulator and how long does it take to change the polymer insulator. Also this paper will give a help in electronic industry and the method of measuring the insulator elasticity modulus of polymer could be utilized in life estimation and replacement time of the products of electronic equipment that is used in real industrial fields.
열화상기술을 이용한 모멘트 변화에 따른 피로균열진전 연구
김경석,정현철,박찬주,정덕운,장호섭,Kim, Kyeong-Suk,Jung, Hyun-Chul,Pack, Chan-Joo,Jung, Duk-Woon,Chang, Ho-Sub 한국생산제조학회 2010 한국생산제조학회지 Vol.10 No.6
The objective of this study is to propose an effective method for measurement and analysis of fatigue crack. A technique that can measure the statue of fatigue crack propagation fast and correctly for enhancing safety of constructions and securing reliability is necessary. Moreover, the crack propagation behavior characteristics evaluation technique has to be developed using this technique. In this paper, fatigue crack was caused via the fatigue experiment with repeated load on the CT specimen that is made up of STS304. Fatigue crack propagation was measured by tracing the position of the maximum temperature according to the cycles using infrared thermography. The crack growth characteristics was evaluated by applying the moment values on the measuring area to the measured value. As a result of this study, the possibility that the infrared thermography could be applied to measure the fatigue crack was identified. Moreover, it was identified that fatigue crack propagation have a relationship with the moment value of construction.
경련성 사경증의 보존적 치료 효과에 대한 문헌적 고찰 -2000년 이후 발표된 논문을 중심으로
김경석,김성수,정석희,이종수,Kim, Kyoung-Seok,Kim, Sung-Soo,Chung, Seok-Hee,Lee, Jong-Soo 척추신경추나의학회 2010 척추신경추나의학회지 Vol.5 No.1
Objects: This study was to report a clinical effect of Chuna Treatment for a patient diagnosed by Magnetic Resonance Imaging(MRI) as Cervical Myelopathy. Methods: In order to alleviate shoulder pain and neck stiffness, the patient was treated by acupuncture therapy, herbal medicine, pharmacopucture, cervical traction technique of Chuna treatment and conservative managements. To evaluate the effect of the treatment, Recovery rate of Hirabayashi, VAS(Visual Analogue Scale), NDI and ROM(Range of Motion) were used. Lhermitte's sign, Valsalva test, Distraction test, Compression test and Spurling test were carried out. Results: VAS, NDI and ROM were improved and Recovery rate was 100%. Conclusions: Korean Treatment can be effectively used for a patient with Cervical Myelopathy. Further clinical studies are needed to verify the findings.