        금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교

        이귀철,박영준,홍주완 한국방사선학회 2023 한국방사선학회 논문지 Vol.17 No.4

        The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

      • Usefulness of conventional axial scan for decreasing radiation dose in chest CT screening

        이귀철(Gui-chul Lee),남태현(Tae-hyun Nam),대창민(Chang-min Dae),정용환(Young-hwan Jung),권순안(Soon-ahn Kwon) 대한CT영상기술학회 2019 대한CT영상기술학회지 Vol.21 No.2

        목적: 1972년 최초의 상용화 CT가 개발 된 이후로 촬영 속도 개선의 측면에서 비약적인 발전이 이루어 졌으며 이는 Spiral CT, MD CT 기술의 도입이 스캔 시간 단축에 큰 역할을 하였다. 하지만 스캔 시간의 단축은 한편으로 방사선량의 증가로 이어 졌으며, 빠른 스캔시간의 이점으로 거의 모든 검사가 Helical scan 방식으로 바뀌어 가고 있는 추세이다. 대상 및 방법: Multi detector의 발전으로 1cycle의 scan으로 z축의 스캔 범위가 넓어짐에 따라 helical scan 에 비해 적은 선량으로 interpolation 없는 영상의 재구성이 가능하여 화질 개선이 가능한 axial scan 방식을 이용하여 low dose chest CT 에서의 유용성을 알아보았다. 결과: 본 연구의 결과에서 helical 방식에 비해 axial 방식이 약 20%의 선량감소 효과를 보였으며, AAPM phantom 과 lungman phantom의 화질평가 결과 CT NO와 noise에서 AAPM Phantom의 경우 모두 유의한 차이(p<0.05)를 보였으며, LUNGMAN phantom의 경우 일부 nodule에서 noise 값의 유의한 차이(p<0.05)를 확인 하였다.AAPM phantom 내의 resolution chat를 image J 를 이용하여 plot profile 분석하여 평균을 낸 결과 helical scan은 2.8개 axial scan은 4.7몇 개의 홀을 구분 할 수 있었다. 결론: Axial scan의 경우 screening을 목적으로 하는 저선량 흉부 CT 또는 Lung field가 성인에 비해 작은 소아 환자의 chest 검사 시 선량을 줄이는 동시에 좋은 화질을 유지할 수 있을 것으로 사료된다. Purpose: Since the first Computed Tomography commercially available in 1972, dramatic improvements have been made in terms of scan speed, which is very important role in shortening the scanning time by adopting the Multi-detector arrayed CT (MDCT) and spiral (helical) CT techniques. Both MDCT and spiral CT techniques are developing to work interactively. A radiographer can choose the scan mode between conventional axial scan mode and spiral (helical) mode. These days, almost all of CT examinations are performing with the helical scan mode. However, spiral (helical) scan mode is faster than conventional axial scan but it leads to the increase of the radiation dose and reducing image quality cause of geometrical and image reconstruction technique reasons such as interpolation technique. Methods: As a result of the development of MDCT, it is possible to reconstruct the image without interpolation with less dose compared to the helical scan as the scan range of the z-axis is widened by 1 cycle scan. Results: The results of this study showed that the conventional axial scan mode reduced the radiation dose about 20% compared to the spiral (helical) mode, and the image quality tests by AAPM phantom and LUNGMAN phantom showed a significant improved (p <0.05), And in the case of LUNGMAN phantom, there was a significant improvement in noise values in nodules measurement. AAPM phantom resolution evaluation measured by plot profile analysis using image J program. As a result, helical scan was able to distinguish 2.8, conventional axial scan 4.7 few holes. Conclusion: In conclusion, conventional axial scan mode may be able to improve image quality while reducing radiation dose in chest examination of low dose screening chest CT and pediatric patients.

      • Traumatic Elbow 환자에 있어 Modify Elbow Oblique View 촬영의 유용성에 관한 연구

        이귀철(GuiChul Lee),오윤아(Yuna Oh),김동영(DongYoung Kim),권순안(SoonAn Gwon),김성룡(SungRyong Kim),민관홍(GwanHong Min) 대한영상의학기술학회 2013 대한영상의학기술학회 논문지 Vol.2013 No.-

        목적: Traumatic elbow 환자 또는 소아환자에 있어 기존 elbow oblique 촬영은 환자가 자력으로 position을 취하기가 매우 어려우며, 손상 부위의 움직임으로 인한 고통 유발 및 상태 악화 등으로 촬영을 포기하거나 정상적 영상 획득이 힘들다. 따라서 검사 시 환자의 움직임을 최소화 할 수 있는 modify elbow oblique 촬영을 연구하여 환자의 고통을 감소시 키며 작업종사자가 받아야 할 불필요한 피폭을 줄이는데 연구의 목적이 있다. 대상 및 방법: 실험에는 X-ray 촬영을 위한 DR system (Discovery XR656, GE, USA)과 영상 평가를 위해 PACS (INFINITY Healthcare, Korea) system을 사용 하였다. 대상은 정상인 성인 10명으로 하였으며, 실험 방법은 Original elbow medial & lateral oblique view 촬영과 modify elbow medial & lateral oblique view 촬영을 1회 하였다. Modify view 의 경우 환자는 true AP position에서 medial oblique 과 lateral oblique 각각 15° 에서 40° 까지 5° 간격으로 tube angle을 주어 촬영 하였다. Tube의 angle의 경우 medial oblique 은 내측으로 lateral oblique는 외측으로 주어 original 촬영법과 흡사한 효과를 얻고자 하였다. 촬영 후 영상은 PACS로 전송하여 방사선사 3인이 평가하여 비교분석 하였다 결과: modify elbow medial oblique의 경우 tube angle 을 medial 쪽으로 35°~40° 정도 주었을 때 평가 항목별 적절한 영상을 얻을 수 있었고, lateral oblique의 경우는 tube angle 을 lateral 쪽으로 30° ~ 35° 주었을 때 평가 항목별 적절한 영상을 얻을 수 있었다. 결론: Traumatic 환자에 있어 modify elbow oblique 촬영의 경우, 환자의 고통 감소와, 손상 부위의 보존에 도움을 줄 수 있으리라 보여지며, 특히 협조가 어려운 소아환자 촬영의 경우 기존 작업 종사자가 환자를 잡고 촬영해야 하는 방식 때문에 작업종사자의 피폭이 있었지만, modify 촬영법의 경우 환자가 움직일 필요가 없으므로 작업종사자의 피폭을 줄이 는데도 큰 도움이 되리라 생각된다. Purpose: The study is to research a modified elbow oblique photography in order to minimize the patients’ movements which minimize the patients’ pain and the unnecessary exposure of the employee. Subject and Method: The subjects were 10 healthy adults the method was to photographthe original elbow medial & lateral oblique view and the modified views once each. After the photography, the images were transmitted to PACS and was evaluated, compared, and analyzed by 3 radiologists. Result: In the case of the modified elbow medial oblique an image relative to the evaluation category was obtained by giving 35°~40° tube angle towards the medial, in the case of the lateral oblique an image relative in the evaluation category was obtained when the tube angle was given 30° ~ 35° towards the lateral. Conclusion: In a traumatic patient the photography of the modify elbow oblique show the minimization of the patients’ pain, the conservation of the impaired region, especially in pediatric patients.