유선국,양호,김선호,김남현,김원기,박상희,Yoo, S.K.,Yang, H.,Kim, S.H.,Kim, N.H.,Kim, W.K.,Park, S.H. 대한의용생체공학회 1988 의공학회지 Vol.9 No.2
A three-dimensional surface is reconstructed from contour information as identified on two-dimensional computed tomographic slices. Gradient operator with curvature constraint would be applied to extract the contour automatically, and backtracking is also adopted to reduce the tracking error. The surface between the consecutive slice is efficiently reconstructed using a triangular surface tiles. Hidden surface elimination, shading and parallel projection of the reconstructed surface are provied on the display screen.
u-헬스케어 응용을 위한 전도성 섬유 심전도 전극의 섬유적 특성 시험 연구
강보규(B. K. Kang),황인호(I. H. Hwang),유선국(S. K. Yoo) 한국재활복지공학회 2012 재활복지공학회논문지 Vol.6 No.2
의료기기의 발전과 IT융합기술의 접목으로 때와 장소에 관계없이 생체신호의 측정이 가능하게 되었으며, 다양한 형태의 u-헬스케어 기기가 개발되어 일상생활과 가정에서 불편함이 없이 건강변수 측정이 가능하게 되었다. 또한 사용자를 고려해 의복처럼 착용하고 생활하며 생체 신호를 측정할 수 있는 스마트 의류에 전도성 섬유의 활용이 이루어지고 있다. 하지만 이러한 u-헬스케어 기기에 대한 연구 및 개발이 우선되고 있는 반면 성능평가 기준 마련은 미흡한 실정이다. 이에 시판전의 시험검사나 시판후의 수거 검사 시에 성능평가를 위한 표준시험방법 개발 등에 따른 가이드라인 마련에 힘을 쓰고 있는 실정이다. 본 논문에서는 섬유적 특성 시험을 통해 전도성 섬유의 착용형 u-헬스케어 기기에 전극으로 접목 가능성 여부를 연구하였다. The combination of developed medical devices and the convergence of IT fusion technologies, health variables became to can be measured without discomfort in everyday life regardless of wherever and whenever. because various types of u-Health medical devices have been developed. Also, by considering the users, biological signals can be measured without difference with wearing general clothing, that conductive fabric is being used as smart clothing. However, considering that there is a growing prevalence of the devices and a great interest in the development of u-Health devices, it is urgent to establish performance evaluation. Accordingly, writing guidelines by force to raise checking before marketed or collecting checks after at the market for standard test methods for evaluating the performance. In this paper, it was studied that the possibility of using conductive fabric as electrodes for Wearable u-Health Devices through the material test of the ffabric.
Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정
우영재(Y. J. Woo),유선국(S. K. Yoo) 대한전기학회 2007 대한전기학회 학술대회 논문집 Vol.2007 No.10
In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.
착용형 유헬스 디바이스의 전자파 흡수율에 대한 영향 연구
황인호(I. H. Hwang),강보규(B. K. Kang),김동근(D. K. Kim),박기정(K. J. Park),유선국(S. K. Yoo) 한국재활복지공학회 2010 한국재활복지공학회 학술대회논문집 Vol.2010 No.11
최근 전기를 이용하는 의료기기 및 유헬스 디바이스 등의 사용 증가와 이에 따른 환자 및 보호자, 의료서비스 종사자들의 전자파 환경 노출이 증가함에 따라 전자파의 인체 영향에 대한 대중적 관심이 증대디고 있다. 또한, 착용형 유헬스 디바이스의 경우 직접 인체에 착용되어 이동성과 편리성을 추구하지만, 전자파 노출에 관해 우려하는 인식이 높은 실정이며, 이러한 관심은 전자파의 인체노출영향에 대한 다양한 보고서와 이에 관한 언론의 발표, 그리고 이것을 만들어내는 불확실성 등이 맞물려 현재까지 밝혀지지 않은 위협에 대한 인식으로 확대되고 있다. 이에, 본 연구에서는 유헬스 디바이스의 전자파 인체 흡수율에 관한 시험을 진행하고, 국제기준에 근거하여 데이터의 특성을 비교, 분석하였으며 향후, 관련 제조자와 사용자 모두에게 전자파 인체 영향에 관한 인식을 해소하는데 기여할 수 있을 것이다.