      • 영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰

        손기경,성동욱,정재호,강희두,류경남,Son, Gi-Gyeong,Sung, Dong-Wook,Jeong, Jae-Ho,Kang, Hui-Doo,Ryu, Kyung-Nam 대한디지털의료영상학회 2008 대한디지털의료영상학회논문지 Vol.10 No.1

        Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

      • 판독용 모니터 정도관리 항목 및 시행기준안 개발 연구

        손기경,성동욱,정해조,정재호,강희두,신진호,이순근,김용환,Son, Gi-Gyeong,Sung, Dong-Wook,Jung, Hae-Jo,Jeong, Jae-Ho,Kang, Hee-Doo,Shin, Jin-Ho,Lee, Sun-Geun,Kim, Yong-Hwan 대한디지털의료영상학회 2007 대한디지털의료영상학회논문지 Vol.9 No.1

        PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

      • KCI등재

        판독용 모니터 정도 관리를 위한 AAPM TG18 측정 도구의 제작과 그 유용성 보고

        손기경,성동욱,정재호,강희두,이정림,정희교 대한영상의학회 2008 대한영상의학회지 Vol.58 No.6

        목적: 판독용 모니터의 정도 관리를 위한 판독자의 1차적 정도관리를 위하여 AAPM TG18측정 도구를 제작하고 그의 유용성을 알아보고자 한다. 대상과 방법: AAPM TG18에 의거한 판독용 모니터 정도 관리를 위해 측정 도구를 제작하였고, 측정 도구를 통해 AAPM TG18의 측정항목을 평가하였다. 측정항목으로는 기하학적 왜곡의 시각적 및 정량적 평가, veiling glare의 시각적 평가, 판독용 모니터 DICOM LUT (Lookup table) 보정(calibration)을 하는 휘도 측정기에 대하여 0% 휘도 조정 작업을 시행하였다. 결과: 측정 도구를 사용함으로써 TG18-QC 테스트 패턴에서 기하학적 왜곡을 정량 평가할 때 공간적 길이를 측정할 수 있고, TG18-GV 테스트 패턴을 이용한 veiling glare 평가 때 상이한 계조의 원형 타겟들에 대한 시각 평가를 할 수 있을 뿐만 아니라, 판독용 모니터에 대한 주기적인 DICOM 보정 작업 시 휘도계측기 센서에 대해 0% 휘도 조정 시 재현성 있는 보조도구로 사용할 수 있었다. 결론: AAPM TG18 측정 도구는 판독용 모니터에 대한 정도관리 시 AAPM TG18의 여러 시험 항목에 대하여 손쉽게 평가할 수 있어, 판독자의 1차적 정도 관리를 수행하는데 유익한 도구라 판단한다.

      • 의료영상 압축을 위한 JPEG2000의 효율성 연구

        정재호,신진호,손기경,강희두,Jung, Jae-Ho,Shin, Jin-Ho,Son, Gi-Gyeong,Kang, Hee-Doo 대한디지털의료영상학회 2003 대한디지털영상기술학회지 Vol.6 No.1

        Purpose : In a PACS(Picture Archiving Communications System) environment, which is a very important component in a digital medical environment, the compression of digital medical images is a necessary and effective feature. In a current system where JPEG is applied to the compression of medical images, this study is to examine effectiveness and suitability when the JPEG2000, a more advanced compression algorithm for still images, is applied to the compression of medical images. In this thesis, we attempt to address the compressibility for effective clinical usage when compressing medical images, applying the objectivization of clinical evaluation as a function of compressibility. In the experiment al method, the compression was applied at a fixed rate using JPEG2000, and the n the result was compared with compressed images by JPEG. Method : For the performance evaluation, we choose SNR(Signal to Noise Ratio) measurement of an objective evaluation of definition and analyze a subjective evaluation by the ROC(Receiver Operating Characteristic) method. The results of the experiment showed that in the case of JPEG2000 there is hardly any distortion of images, even at high compression ratio(100:1), while regarding noise, the SNR remains around about 40dB, which is also relatively high. Before reading by reference to evaluative materials concerning objective compressed images, it is impossible to apply high compression to images : however, after reading, this can be applied to images that have already existed for some time.

      • DICOM 객체를 활용한 무결성 PACS Data 관리시스템 구현

        박범진,정재호,손기경,정영태,강희두,Park, Bum-Jin,Jeong, Jae-Ho,Son, Gi-Gyeong,Jung, Young-Tae,Kang, Hee-Doo 대한디지털의료영상학회 2013 대한디지털의료영상학회논문지 Vol.15 No.1

        PACS is one of the most used medical information system and share information from other hospitals through the PACS. Data integrity means zero defects data and this is a prerequisite of information system performance. but I wonder if I can trust these informations that Incorrect information from radiotechnologist's mistakes, anonymous in emergency department, Newborn baby department, modified informations at later. And Modified informations causes defect in integrity of the data. When we import, we use DICOM header not DB data. so error occurs that DB data is deferent with DICOM Header information. This paper discusses to resolve as above problem using DICOM object such as DICOM PR, SR. And propose quality management system that can guarantee the patient information and can manage exam history.

      • 경희의료원 PACS 운영관리를 위한 외주관리와 제안요청 연구

        강희두,정재호,손기경,성동욱,Kang, H.D.,Jung, J.H.,Son, G.G.,Seong, D.U. 대한디지털의료영상학회 2007 대한디지털의료영상학회논문지 Vol.9 No.1

        PACS 유지보수 서비스의 중요성을 살펴보고 PACS 분분별 제안요청 요소를 분석하여 향후 시스템 유지보수 계약의 지표를 제공하는데 목적이 있으며 경희의료원의 PACS 유지보수 제안서요청의 사례를 중심으로 유지보수 RFP 작성의 필요성, 중요사항 및 분야별 요구사항 등에 대하여 기술한다. 제안 부문은 9 개로 구분하였으며 총 139 항목의 제안 요청 사항을 정리하였다. 제안 요소 연구의 결과는 다음과 같다. 1. PACS 유지보수 분야는 PACS Software 부문, 데이터베이스 부문, 서버 및 스토리지 부문, 네트워크 부문, CR 및 DR System 등과 같은 영상획득장치에 관한 부문, 판독용 및 임상용 모니터 부문 등으로 구분하며, 각 부문별 제안 요구사항을 기술한 제안요청서를 작성하여 각 부문별 제안서를 요청하여야 한다. 2. 병원에서는 PACS 부문의 외주관리를 체계적으로 구분 관리하여 시스템 유지보수의 수준을 높이고 이를 질 높은 의료서비스로 연계되도록 하여야 한다. 3. PACS 관련 회사는 병원에서 요청된 제안 요청사항을 수용하며 질 높은 관련부문 서비스를 제공하기위한 기술적 배경을 체계화하여야하며 향후 주요 매출원으로 자리 잡게 될 유지보수 서비스를 상품으로 인식하고 이에 대한 적극적인 상품화전략과 홍보 노력이 필요하다.

      • PACS DATA CD의 호환성 평가 및 DICOM 적합성에 대한 검증을 통한 기준 제시

        정재호,성동욱,박범진,손기경,강희두,Jeong, Jae-Ho,Sung, Dong-Wook,Park, Bum-Jin,Son, Gi-Gyeong,Kang, Hui-Doo 대한디지털의료영상학회 2008 대한디지털의료영상학회논문지 Vol.10 No.1

        Purpose To analyze the input and output error of data CD which records the image information and the problems of the server of the compatibility. And to report a compatibility assessment and verification of suitable to DICOM of PACS data CD with investigation of current situation of Korea METHOD AND MATERIALS Date CD of each 8 vendors in 30 hospitals was analyzed. We grasped a main verification element existence of a generation compatibility of data CD. The items of element are media identification, DICOM compression, DICOM viewer send, specified object information modify, auto-run, DICOM content type, etc, and give 1 point for each item. We divided the assessment about an each item into 5 levels. Verification about. DICOM conformance by using DICOM validation tool kit is shown to be classified pass or fail according to error occurrence of tag valus. Classify the prequency of tag occurrence as the item. RESULTS The average point of date CD compatibility is 8 point (very good), lowest is 5 point (6.6%), and highest is 10 point (23%_. Most high occurrence frequency's distribution is 7 point (36.6%). As a result of verification about DICOM conformance, PASS in 8 occurrence frequency's distribution is 7 point (36.6%). As a result of verification about DICOM maximum length numbers (14 items), DICOM error of modality (10 items), discord of pixel data length (6 items). etc.