http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가
박은천(Park, Eun-Churn),이성경(Lee, Sung-Kyung),윤경조(Youn, Kyung-Jo),정희산(Chung, Hee-San),이헌재(Lee, Heon-Jae),최강민(Choi, Kang-Min),문석준(Moon, Suk-Jun),정형조(Jung, Hyung-Jo),민경원(Min, Kyung-Won) 한국소음진동공학회 2008 한국소음진동공학회 논문집 Vol.18 No.1
This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.
대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용
박은천,이성경,이헌재,문석준,정형조,민경원,Park, Eun-Churn,Lee, Sung-Kyung,Lee, Heon-Jae,Moon, Suk-Jun,Jung, Hyung-Jo,Min, Kyung-Won 한국전산구조공학회 2008 한국전산구조공학회논문집 Vol.21 No.5
실시간 하이브리드 실험법(real-time hybrid testing method)은 구조물의 수치해석부와 실험부 부분구조를 운동방정식으로 통합하여 실시 간으로 동시에 계산과 실험을 수행하는 방법이다 본 연구는 실시간 하이브리드 실험법을 사용하여 수동 및 준능동 MR감쇠기가 설치된 건축구조물의 내진성능을 정량적으로 평가한다. 건물 모델은 실물 크기 5층 건물을 강제진동실험 결과를 통해 식별한 수치모델로 사용하였고, MR감쇠기는 실험적 부분구조르 UTM에 설치되었다. 본 연구에서 수행되는 실시간 하이브리드 실험은 사인파 및 지진파 가진을 통하여 얻은 결과와 전류에 따른 MR감쇠기의 제어력을 이용하여 얻은 Bouc-Wen모델을 사용하여 얻은 해석모델과 일치함으로 그 유효성을 입증하였다. 또한 예비연구로써 구조물의 응답을 최적으로 제어하기 위한 clipped-optimal 제어알고리즘과 modulated homogeneous friction 준능동 제어알고리즘을 MR감쇠기에 적용하였다. 각 전류별 Bouc-Wen모델을 곡선맞춤하여 각각의 Bouc-Wen모델 파라미터를 식별하였으며 그 결과를 준능동 제어알고리즘 수치해석에 적용하였다. 또한 실시간 하이브리드 실험법을 이용한 준능동 제어 실험결과와 해석결과를 비교하여 준능동 제어알고리즘의 성능을 평가함에 있어 실시간 하이브리드 실험이 합리적임을 보여준다. The real-time hybrid testing method(RT-HYTEM) is a structural testing technique in which the numerical integration of the equation of motion for a numerical substructure and the physical testing for an experimental substructure are performed simultaneously in real-time. This study presents the quantitative evaluation of the seismic performance of a building structure installed with an passive and semi-active MR damper by using RT-HYTEM. The building model that was identified from the force-vibration testing results of a real-scaled 5-story building is used as the numerical substructure, and an MR damper corresponding to an experimental substructure is physically tested by using the universal testing machine(UTM). The RT-HYTEM implemented in this study is validated because the real-time hybrid testing results obtained by application of sinusoidal and earthquake excitations and the corresponding analytical results obtained by using the Bouc-Wen model as the control force of the MR damper respect to input currents were in good agreement. Also for preliminary study, some semi-active control algorithms were applied to the MR damper in order to control the structural responses optimally. Comparing between the test results of semi-active control using RT-HYTEM and numerical analysis results show that the RT-HYTEM is more resonable than numerical analysis to evaluate the performance of semi-active control algorithms.
준능동 MR감쇠기가 설치된 실물크기 구조물의 분산제어 알고리즘 성능평가
윤경조(Youn, Kyung-Jo),박은천(Park, Eun-Churn),이헌재(Lee, Heon-Jae),문석준(Moon, Seok-Jun),민경원(Min, Kyung-Won),정형조(Jung, Hyung-Jo),이상현(Lee, Sang-Hyun) 한국소음진동공학회 2008 한국소음진동공학회 논문집 Vol.18 No.2
In this study, seismic response control performance of decentralized response-dependent MR damper which generates the control force using only the response of damper-installed floor, was experimentally investigated through the tests of a full-scale structure installed with large MR dampers. The performance of the decentralized control algorithm was compared to those of the centralized ones such as Lyapunov, modulated homogeneous friction, and clipped-optimal control. Hybrid mass damper were controlled to induce seismic response of the full-scale structure under El Centro earthquake. Experimental results indicated that the proposed decentralized MR damper provided superior or equivalent performance to centralized one in spite of using damper-installed floor response for calculating input voltage to MR damper.