곽철훈,최규하 전력전자학회 2003 전력전자학회 논문지 Vol.8 No.6
The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.
곽철훈,최규하 전력전자학회 2003 전력전자학회 논문지 Vol.8 No.6
PWM 인버터의 출력전압을 제어하는 방식에는 2가지 제어기법이 있다. 첫 번째 방법은 전류제어기를 사용하여 출력전압을 제어하는 이중 제어루프를 갖는 제어방식이며, 두 번째 방법은 단일루프만으로서 출력전압을 제어하는 제어방식이다. 일반적으로 3상 PWM 인버터의 제어기는 각상 제어 PI제어기, 2상 정지좌표계 PI제어기, 동기 좌표계 PI제어기로 구성되며, 각상제어 PI제어기를 이용하여 3상의 독립된 출력측 전압 및 전류를 제어하도록 구성된다. 단일루프 전압제어기는 높은 출력 임피던스의 경우 이중제어루프 도다 더 낮은 성능을 나타내기만, 낮은 출력임피던스의 경우에는 또는 부하범위에서 좋은 제어성능을 나타낸다. 또한 시뮬레이션과 실험을 통하여 이를 검증하였다. There arc two ways in the output voltage control method in PWM inverters. One Is double loop voltage control composed of inner current control loop and outer voltage control loop.'rho other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. However, in case of low output impedance, it shows good control performance in all load ranges than double loop voltage control. In this paper, the rule and the gain of single loop voltage control have been developed analytically and these were verified through computer simulation and experiment.
곽철훈,최규하 전력전자학회 2003 전력전자학회 논문지 Vol.8 No.6
The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.
곽철훈(C.H Kwak),정석언(S.O Jung) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
플라이휠 에너지 저장장치는 회전하는 물체에 에너지를 저장하고 이 에너지를 필요 시 기계적인 에너지를 변환하여 전기적 축전지이다. 플라이휠은 무정전전원장치의 직류측의 단자에서 전원을 받아 충전되며, 무정전전원장치의 입력 AC전압이 차단되어 UPS DC bus전압이 설정 값 이하로 떨어지면 저장 되어있는 에너지를 전력변환 모듈에 의해 DC로 변환하여 UPS에 공급한다. 또한 전압 Sag, 전압의 불평형, 순간정전 및 고조파에 의한 정전에 대비하여 축전지와 플라이휠 에너지 저장장치를 조합하여 운용할 경우 축전지와 UPS의 DC BUS가 전기적으로 절연이 되어 개별 축전지 구성과 동일한 동작이 되도록 구성으로 축전지의 방전 횟수를 감소함으로써 축전지의 수명도 연장 할 수 있습니다.