http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Masatoshi Ogawa,Hiroshi Endo,Hiroyuki Fukuda,Hiroyoshi Kodama,Toshio Sugimoto,Takeshi Horie,Tsugito Maruyama,Masao Kondo 제어로봇시스템학회 2013 제어로봇시스템학회 국제학술대회 논문집 Vol.2013 No.10
A cooling control method based on a model predictive control (MPC) for a modular datacenter utilizing the fresh-air is proposed. The proposed method reduces the total energy consumption of information technology (IT) equipment and cooling facilities in the data center, while considering a relationship between energy-savings and the temperature information of IT equipment. This method based on MPC controls the central processing unit (CPU) temperature in servers by facility fans for cooling. To design the proposed method, it is developed a prediction model that represents the CPU temperature by the revolution speed of facility fans, the fresh-air temperature, utilization of servers, and other factors. Furthermore, the proposed control method is applied to the actual modular data center. The energy consumption of the proposed method is compared with that of a traditional method, which has controlled the temperature difference between the inlet and outlet of the server racks based on proportional integral (PI) control. Actual comparison experiments with traditional method are provided to validate effectiveness of the proposed method. The results show that the proposed method realizes energy-savings of more than 20% compared to the traditional control method in the actual modular datacenter.
Tadayuki Takagi,Mitsuru Sugimoto,Hidemichi Imamura,Yosuke Takahata,Yuki Nakajima,Rei Suzuki,Naoki Konno,Hiroyuki Asama,Yuki Sato,Hiroki Irie,Jun Nakamura,Mika Takasumi,Minami Hashimoto,Tsunetaka Kato 대한소화기내시경학회 2023 Clinical Endoscopy Vol.56 No.1
high tumors. Therefore, sufficient sampling of histological specimens is necessary in cases of unresectable pancreatic cancer (UR-PC). This multicenter study investigated the efficacy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) using a Franseen needlefor MSI evaluation in patients with UR-PC. Methods: A total of 89 patients with UR-PC who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) orEUS-FNB using 22-G needles at three hospitals in Japan (2018–2021) were enrolled. Fifty-six of these patients (FNB 23 and FNA 33)were followed up or evaluated for MSI. Patient characteristics, UR-PC data, and procedural outcomes were compared between patientswho underwent EUS-FNB and those who underwent EUS-FNA. Results: No significant difference in terms of sufficient tissue acquisition for histology was observed between patients who underwentEUS-FNB and those who underwent EUS-FNA. MSI evaluation was possible significantly more with tissue samples obtained usingEUS-FNB than with tissue samples obtained using EUS-FNA (82.6% [19/23] vs. 45.5% [15/33], respectively; p<0.01). In the multivariateanalysis, EUS-FNB was the only significant factor influencing the possibility of MSI evaluation. Conclusions: EUS-FNB using a Franseen needle is desirable for ensuring sufficient tissue acquisition for MSI evaluation.
( Yoshiki Hirooka ),( Akihiro Itoh ),( Hiroki Kawashima ),( Eizaburo Ohno ),( Yuya Itoh ),( Yosuke Nakamura ),( Takeshi Hiramatsu ),( Hiroyuki Sugimoto ),( Hajime Sumi ),( Daijiro Hayashi ),( Naoki Oh 대한소화기학회 2013 Gut and Liver Vol.7 No.4
Background/Aims: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonographyTM technology (ZST; Fujifilm Corp.). Methods: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. Results: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49 0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. Conclusions: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited. (Gut Liver 2013; 7:486-491)