RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Profiling Total Viable Bacteria in a Hemodialysis Water Treatment System

        ( Lihua Chen ),( Xuan Zhu ),( Menglu Zhang ),( Yuxin Wang ),( Tianyu Lv ),( Shenghua Zhang ),( Xin Yu ) 한국미생물 · 생명공학회 2017 Journal of microbiology and biotechnology Vol.27 No.5

        Culture-dependent methods, such as heterotrophic plate counting (HPC), are usually applied to evaluate the bacteriological quality of hemodialysis water. However, these methods cannot detect the uncultured or viable but non-culturable (VBNC) bacteria, both of which may be quantitatively predominant throughout the hemodialysis water treatment system. Therefore, propidium monoazide (PMA)-qPCR associated with HPC was used together to profile the distribution of the total viable bacteria in such a system. Moreover, high-throughput sequencing of 16S rRNA gene amplicons was utilized to analyze the microbial community structure and diversity. The HPC results indicated that the total bacterial counts conformed to the standards, yet the bacteria amounts were abruptly enhanced after carbon filter treatment. Nevertheless, the bacterial counts detected by PMA-qPCR, with the highest levels of 2.14 × 107 copies/100 ml in softener water, were much higher than the corresponding HPC results, which demonstrated the occurrence of numerous uncultured or VBNC bacteria among the entire system before reverse osmosis (RO). In addition, the microbial community structure was very different and the diversity was enhanced after the carbon filter. Although the diversity was minimized after RO treatment, pathogens such as Escherichia could still be detected in the RO effluent. In general, both the amounts of bacteria and the complexity of microbial community in the hemodialysis water treatment system revealed by molecular approaches were much higher than by traditional method. These results suggested the higher health risk potential for hemodialysis patients from the up-to-standard water. The treatment process could also be optimized, based on the results of this study.

      • SCOPUSKCI등재

        Changes in extracellular water and left ventricular mass in peritoneal dialysis patients

        ( Theerasak Tangwonglert ),( Andrew Davenport ) 대한신장학회 2021 Kidney Research and Clinical Practice Vol.40 No.1

        Background: Increasing number of peritoneal dialysis (PD) patients are reported to have increased left ventricular hypertrophy (LVH), a major risk factor for cardiovascular mortality. We wished to determine which factors were most associated with changes in left ventricular mass index (LVMI). Methods: We reviewed patient and treatment factors in prevalent PD patients with repeat echocardiograms 18 to 24 months apart, with corresponding bioimpedance measurements of extracellular water (ECW) and serum N-terminal pro-brain natriuretic peptide (NT-proBNP). Results: We studied 60 patients (34 males, 35 with diabetes) who were treated with PD for a median of 14 months (2.5-26.3 months). All but one had LVH; on repeat echocardiography, there was no overall change in LVMI (106 [84-127] g/㎡ vs. 108 [91- 122] g/㎡) despite a loss of residual renal function. Left ventricular mass increased in 34 (56.7%), and the percent change in LVMI was associated with percent change in NT-proBNP (r = 0.51, p = 0.017) and ECW/height (r = 0.32, p = 0.029), but not with ECW/total body water or changes in systolic or mean arterial pressure, urine output, 24-hour PD ultrafiltration, or net sodium balance. Only ECW/height remained independently associated with the percent change in LVMI in a multivariable model (odds ratio, 1.25; 95% confidence interval, 1.08-1.36; p = 0.007). Conclusion: In this observational longitudinal report, a reduction in ECW/height was associated with regression of LVMI, whereas an increased ECW/height was associated with increased LVMI. As there was no corresponding association with systolic or mean arterial pressure, then volume expansion would appear to be a more significant factor in determining LVH than blood pressure.

      • KCI등재

        Thermal and Hygroscopic Properties of Indoor Particulate Matter Collected on an Underground Subway Platform

        마창진,이경빈,Daizhou Zhang,Mariko Yamamoto,김신도 한국대기환경학회 2015 Asian Journal of Atmospheric Environment (AJAE) Vol.9 No.3

        In order to clarify the thermal and hygroscopic properties of indoor particulate matter (PM) in a semiclosed subway space, which is critically important for understanding of the distinctive particle formation processes as well as the assessment of their health effects, the size-resolved PMs (i.e., PM2.5 and PM10-2.5) were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4. The elemental concentrations in soluble and insoluble fractions were determined by PIXE from the bulkily pretreated PM2.5. The thermal and hygroscopic characteristics of individual particles were investigated via a combination of the unique pretreatment techniques (i.e., the high-temperature rapid thermal process and the water dialysis) and SEM-EDX analysis. Iron and calcium were unequaled in insoluble and soluble PM2.5 fractions, respectively, with overwhelming concentration. The SEM-EDX’s elemental net-counts for the pre- and post-pyrolyzed PMs newly suggest that magnesium and several elements (i.e., silica, aluminum, and calcium) may be readily involved in the newly generated subway fine PM by a high-temperature thermal processing when trains are breaking and starting. Through the water dialysis technique, it turned out that calcium has meaningful amount of water soluble fraction. Furthermore, the concentrations of the counter-ions associated with the calcium in subway PM10-2.5 were theoretically estimated.

      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼