RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Adaptive Event-triggered Fault Detection Filter for a Class of Conic-type Nonlinear Hidden Semi-Markov Jump Systems

        Kaixuan Chen,Xiang Zhang,Shuping He,Kaibo Shi,Yanyan Yin 제어·로봇·시스템학회 2022 International Journal of Control, Automation, and Vol.20 No.11

        This paper investigates the filtering-based asynchronous fault detection problem for a class of continuoustime conic-type nonlinear semi-Markov jump systems via adaptive event-triggered approach. Firstly, the asynchrony of filter modes and system modes are described by a hidden semi-Markov model. Secondly, an adaptive eventtriggered scheme is developed to reduce the transmissions from the system to the designed filter and improve the efficiency of data transmission. Then, by applying linear matrix inequalities techniques, sufficient conditions are obtained to ensure the stochastic stability and H∞ performance of the fault detection system. Finally, a tunnel diode circuit model is given to confirm the accuracy and effectiveness of the designed approach.

      • KCI등재

        변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향

        윤미정,윤민철,엄태관,허중보,정창모 대한치과보철학회 2012 대한치과보철학회지 Vol.50 No.2

        Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing. 연구 목적: 지금까지 성공적인 임플란트 치료를 위해 많은 연구가 진행되어 왔으며, 임플란트 주변 골 흡수 현상에 대한 연구는 매우 관심이 높은 분야 중 하나이다. 이에 본 연구에서는 삼차원 유한요소응력분석을 이용하여 변연골 흡수가 내측연결 임플란트 매식체의 기계적 안정성에 미치는 영향을 간접적으로 확인하고자 하였다. 연구 재료 및 방법: 악골에 식립된 내측연결 형태의 임플란트 매식체에 티타늄 소재의 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 삼차원 유한요소모형을 설계하였다. 0, 1, 2, 3 mm의 변연골 흡수 상태를 적용하고, 교합면 중심에서부터 3 mm 편측에 300 N의 수직 하중을 가하여 임플란트 매식체에 발생하는 최대 주응력을 계산하였다. 결과: 유한요소분석결과 변연골 흡수에 따른 임플란트 매식체의 최대 주응력 분포는 유사한 양상을 보였으며, 임플란트 매식체 상단에서 가장 높은 응력 집중이 나타났다. 최대 주응력은 처음 1 mm 변연골 흡수를 가정하였을 때 가장 크게 증가하였고, 이후 변연골 흡수가 증가할수록 응력은 증가하였지만 응력 증가의 폭은 감소하는 경향을 보였다. 결론: 이러한 결과로부터 내측연결 임플란트에서 매식체 두께가 얇은 경부의 노출은 변연골 흡수로 인한 응력 증가에 가장 큰 원인임을 알 수 있었으며, 매식체의 변형, 균열 및 파절 등의 기계적 실패를 감소시키기 위해서는 이에 대한 외과적, 보철적 고려가 필요할 것으로 생각된다.

      • KCI등재후보

        중앙아시아 전통 관모를 응용한 현대 모자 디자인

        노지원,장민정 한복문화학회 2019 韓服文化 Vol.22 No.3

        Historically, hats have been worn to protect the head from the environment. As time progressed, it was a symbol of not only the purpose of protection but also the status, economic power, religion, nationality, political beliefs and occupation of each individual. In modern society, hats are added to the decorative function with the development of fashion, so that everyone of all ages are wearing them as fashion accessories. In the 21st century, folk dress has the value of new re-creation in terms of internationalization and has a multifaceted use. Therefore, in modern times, it is necessary to develop a functional and practical hat design that can use the tradition and fit the world. It is very meaningful to present new creative possibilities based on traditions that fit the era of internationalization. In this study, we reviewed the Central Asian traditional hats, called ‘Gwanmo’, that have various forms due to the religious and cultural influences of Muslims, and designed 6 modern hats for creative design by utilizing their formative characteristics. First, the design using tubular Gwanmo was reborn as a modern and practical hat by using some form changes and traditional patterns. Secondly, the design using conical Gwanmo adds new formativeness and enables a special design that gives emotional fashion and fun. Third, the design using hooded Gwanmo was recreated as a unique design that is very ethnic and stylish. As such, the modern hat design using the traditional Gwanmo is presented in various forms that are not uniform, and it is meaningful to suggest the possibility of using it as a new design to stimulate emotion. In the future, we hope that the research on traditional costumes of various regions at home and abroad and the design development will follow. 예로부터 모자는 환경으로부터 머리를 보호하기 위해 착용되어 왔다. 또한 시간이 흐를수록 보호의 목적뿐만 아니라 개인의 지위, 경제력, 종교, 국적, 정치적 신념, 직업의 상징이기도 하였다. 그리고 현대사회에서는 모자가 패션의 발달과 함께 장식기능에 추가되어 남녀노소 누구나 패션 장신구로 착용하고 있다. 21세기의 민속 복식은 국제화 측면에서 새로운 재창조의 가치를 지니고 있으며, 다양한 용도를 가지고 있다. 따라서 현대에 살고 있는 우리는 전통을 이용하고 세계에 맞는 기능적이고 실용적인 모자 디자인을 개발할 필요가 있다. 국제화 시대에 걸맞은 전통을 바탕으로 새로운 창조적 가능성을 제시하는 것은 매우 의미가 있다. 이를 바탕으로 본 연구에서는 이슬람교도의 종교적, 문화적 영향으로 다양한 형태를 가진 중앙아시아 전통모자 '관모'를 검토하고, 그 조형적 특성을 살려 창의적 디자인을 위한 현대모자 6개를 설계하였다. 먼저 관모(關母)를 사용한 디자인은 어떤 형태 변화와 전통적인 패턴을 사용함으로써 현대적이고 실용적인 모자로 재탄생되었다. 둘째, 원뿔형 관모를 사용한 디자인은 새로운 포맷성을 더하고 감성적인 패션과 재미를 주는 특별한 디자인을 가능하게 한다. 셋째, 후드 관모를 사용한 디자인은 매우 민족적이고 세련된 독특한 디자인으로 재탄생되었다. 이와 같이 전통적인 관모를 활용한 현대적인 모자 디자인은 획일적이지 않은 다양한 형태로 제시되고 있으며, 감성을 자극하는 새로운 디자인으로 활용할 수 있는 가능성을 시사하는 의미가 있다. 앞으로 국내외 다양한 지역의 전통 의상에 대한 연구와 디자인 개발이 뒤따를 것으로 기대한다.

      • KCI등재

        치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구

        윤미정(Mi-Jung Yun),허중보(Jung-Bo Huh),정창모(Chang-Mo Jeong),전영찬(Young-Chan Jeon),강은숙(Eun-Sook Kang) 대한치과의사협회 2015 대한치과의사협회지 Vol.53 No.5

        Purpose : The purpose of this study was to evaluate the effect of amount of cantilever in intra-crown according to implant fixture position on mechanical strength of internal conical joint type implant. Materials and Methods : Internal conical joint type implant fixture, abutment screw, abutment was connected and gold alloy prostheses were fabricated and cemented on abutment. For fatigue fracture test, the specimens were loaded to the 350 N, 2,000,000 cycle on 3, 4, 5, and 6 mm off-center of gold alloy prostheses. The fracture pattern of implant component was observed. Results : No fatigue fracture found on 3 and 4 mm group . But initial crack pattern found on 3 specimens of 4 mm group. Fatigue fracture found on all specimens of 5 mm group. But complete fracture was not observed. One specimen of 6 mm group fracture completely. Implant fixture fracture wax not observed. Conclusion : The mechanical failure of implant prostheses increased with the loading area farther from center of implant fixture. To reduce mechanical problem of internal joint type implant, surgical and prosthetic consideration is needed.

      • Design of the Brake Device Using the Axial Crushing of Truncated Cone Type Cylinder

        Jichul KIM,Woo Jeon SHIM 한국트라이볼로지학회 2002 한국트라이볼로지학회 학술대회 Vol.2002 No.10

        A brake device lor the high-speed impacting object is designed using an axial crushing of thin-walled metal cylinder. Thickness of the cylinder is increased smoothly from the impacting end to the fixed end, resulting in the truncated cone shape. Truncated cone shape ensures that plastic hinges are formed sequentially from impacting end. This increases the reliability of brake device working. Computational and real experiments were performed to verity the effects of conical angle. Results indicate that undesirable sudden rise of crushing load can be prevented by applying appropriate conical angle.

      • KCI등재
      • KCI등재
      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼