http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
수직 충격파 이론을 이용한 레이저 절단용 초음속 보조 가스의 효과 분석
김두승,이승헌,박병훈,강성원 대한기계학회 2019 大韓機械學會論文集B Vol.43 No.4
The behavior of the assist gas in a laser cutting process affects the cutting quality. In this study, numerical analysis was conducted to analyze the trend in cutting quality with respect to the nozzle design and stand-off distance. For this purpose, a supersonic nozzle was designed based on the method of characteristics to maintain the cutting quality regardless of the stand-off distance. For a simplified laser cutting process with a minimum length nozzle or conical nozzle, numerical simulations were performed for a set of stand-off distances using a Reynolds-averaged Navier–Stokes model. Finally, based on the structural similarity between flows, the normal shock theory was examined to predict the trend in cutting quality from a free jet simulation. 레이저 절단 과정에서 보조 가스의 거동은 절단 품질에 영향을 준다고 알려져 있다. 본 연구에서는 노즐 형상과 절단 거리에 따른 절단 품질의 경향성을 분석하고자 수치 해석을 수행하였다. 이를 위해 먼저 특성곡선법을 이용하여 절단 거리와 무관하게 절단 품질을 유지할 수 있는 초음속 노즐의 형상을 설계하였다. 다음으로 레이저 절단 과정을 축대칭 조건을 사용하여 모사하였다. RANS 기법을 이용하여 최소 길이 노즐과 원뿔형 노즐에 대해 절단 거리에 따른 수치 해석을 수행하였고, 유동의 구조적 유사성을 바탕으로 수직 충격파 이론을 도입하여 절단 거리에 따른 절단 품질의 경향성을 예측했으며, free jet 해석 결과로부터 절단 성능 예측의 가능성을 확인하였다.
방연규 ( Yeoun Gyu Pang ),김상헌 ( Sanghun Kim ) 한국농업기계학회 2017 한국농업기계학회 학술발표논문집 Vol.22 No.2
깨와 같이 곡물의 크기가 작은 작물을 탈곡하는데 있어서, 장치의 단순성이나 효율적 에너지 사용 면에 장점을 가지고 있는 상향식 로타리 타격 방식의 탈곡장치에 대한 탈곡 요인 분석을 실시하였다. 타격날로 충격절단을 하는 경우, 줄기가 회전날에 감기는 문제도 발생하기 때문에 적당한 길이로 줄기를 잘라주어야 한다. 공급된 줄기가 로타리 회전날에 의해 충격 절단되기 위해서는 줄기가 회전날에서 회전축 방향으로 진입하는 일정한 길이가 존재하는데 이것에 미치는 영향을 분석 하기위해 줄기의 공급속도와 회전날 각도의 변화에 따른 줄기의 절단길이를 측정하였다. 또한 절단시까지의 피타격 횟수는 탈립율에 영향을 미치는데 이를 구명 하기 위한 관계식을 제시 하였다. 수확 후 10일간 건조한 참깨줄기를 공급속도 2.2 m/s, 1.1 m/s, 0.5 m/s, 0.1 m/s,로 공급하고 4개의 바 형태의 날을 부착한 선속도 13.5 m/s의 로타리로 타격한 결과 절단줄기의 길이는 각각 평균 11.7 cm, 8.8 cm, 8.1 cm, 8.5 cm로 나타났다. 탈립율은 모두 99.9%로 나타나 공급속도로 인한 탈립율 저하는 일어나지 않는 것으로 나타났다.
최창선(Chang Sun Choi),강원규(Won Kyu Kang) 한국추진공학회 2011 한국추진공학회 학술대회논문집 Vol.2011 No.11
직경 22 mm 정도의 케이블 절단을 위한 케이블커터의 화약량 예측을 위하여 인스트론을 사용한 정적 절단 시험과 Impact test machine을 이용한 낙하충격 시험을 실시하였다. 인스트론 시험 결과 케이블 절단에 필요한 에너지는 21.3 J로 측정되었다. Impact test는 5종류의 에너지 레벨에서 각각 8번씩 시험하였다. Impact test 시험 결과를 Probit 방법으로 분석한 결과, 99% 신뢰도에서 99.99% 절단하는 에너지는 37.7 J 로 예측되었다. 이 에너지는 ZPP 230 mg 이면 발생 가능할 것으로 판단된다. We performed Instron and Impact tests to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 mm. The cutting energy measured by Instron was 21.3 J. Impact test were performed 8 times each at 5 different energies. The Impact test results were analysed by Probit methods. The cutting energy was calculated 37.7 J with 99.99% probability at 99% confidence, which is roughly equivalent to 250 mg of Zirconium potassium Perchlorate (ZPP).
은헌정,권태완,이선미,김태형,최말례,조수진 大韓神經精神醫學會 2005 신경정신의학 Vol.44 No.3
Objectives : The present study was conducted to explore the reliability and validity of the "Impact of Event Scale-RevisedKorean version" (IES-R-K). Methods : The subjects were college students who visited a college counseling center and patients who were admitted to a general hospital and two orthopedic local clinics.Those subjects who experienced catastrophic traumatic events were tested for CAPS, BDI, STAI-I, II, and MMPI-PTSD scale. Results : The range of correlations between item-total were .45 -.89. The coefficients of internal consistency were .69 -.83, of them were the Split-half reliability was .71 and the test-retest reliability was .89, all within expected ranges. Inter-corre-lations of IES-R-K, CAPS, BDI, STAI-I, II, and MMPI-PTSD scale were high. CAPS showed the highest correlation Coef-ficient. Factor analysis indicated 4 factors in IES-R ; avoidance, hyperarousal, intrusion, and sleep problem & numbness. IES-R-K can be a useful self-rating diagnostic instrument for PTSD symptoms to be a clinical concern by using 24/25 cutoff in total score. The partial PTSD cutoff score is 17/18. Conclusion : The IES-R-K was confirmed in it's reliability and validity. IES-R-K could be applied for screening of PTSD.
이권희,구병수,김희동,Lee, Gwon-Hui,Gu, Byeong-Su,Kim, Hui-Dong 대한기계학회 2001 大韓機械學會論文集B Vol.25 No.12
Supersonic coaxial jets are investigated numerically by using the axisymmetric, Wavier-Stokes equations which are solved using a fully implicit finite volume method. Three different kinds of coaxial nozzles are employed to understand the flow physics involved in the supersonic coaxial jets. Two convergent-divergent supersonic nozzles are designed to have the same Mach number 2.0, and used to compare the coaxial jet flows with those discharging from one constant-area nozzle. The impingement angle of the annular jets are varied. The primary pressure ratio is changed in the range from 2.0 to 10.0 and the assistant jet ratio from 1.0 to 3.0. The results obtained show that the fluctuations of the total pressure and Mach number along the jet axis are much higher in the constant-area nozzle than those in the convergent-divergent nozzles, and the constant-area nozzle lead to higher total pressure losses, compared with the convergent-divergent nozzles. The assistant jets from the annular nozzle affect the coaxial jet flows within the distance less than about ten times the nozzle throat diameter, but beyond it the coaxial jet is conical with self-similar velocity profiles. Increasing both the primary jet pressure ratio and the assistant jet pressure ratio produces a longer coaxial jet core.
최창선(Chang Sun Choi) 한국추진공학회 2012 한국추진공학회지 Vol.16 No.4
We performed impact test to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 ㎜. The impact test results were analyzed by Probit method. The cutting energy was calculated 37.7 J with 99.99% probability at 99% reliability compared to the average energy of 24.9 J. The cable was cut 3 times without failure with 150 ㎎ of Zirconium Potassium Perchlorate (ZPP), which was considered to generate 24.5 J of mechanical energy with assumption that only 10% of explosive energy converts to mechanical energy. The calculated energy from measured pressure with 150 ㎎ ZPP was 26.1 J, which is almost same with both impact test result and expected mechanical energy. We can argue that the cable can be cut with 99.99% probability at 99% reliability by 230 ㎎ of ZPP.